DOWNLOAD LG 32LN52XX / 32LN520B (CHASSIS:LD36M) Service Manual ↓ Size: 8.68 MB | Pages: 75 in PDF or view online for FREE

Model
32LN52XX 32LN520B (CHASSIS:LD36M)
Pages
75
Size
8.68 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
32ln52xx-32ln520b-chassis-ld36m.pdf
Date

LG 32LN52XX / 32LN520B (CHASSIS:LD36M) Service Manual ▷ View online

- 13 -
* Auto-control interface and directions
(1)  Adjust in the place where the influx of light like floodlight 
around is blocked. (illumination is less than 10 lux).
(2)  Adhere closely the Color analyzer(CA210) to the module 
less than 10 cm distance, keep it with the surface of the 
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
-  After aging start, keep the power on (no suspension of 
power supply) and heat-run over 5 minutes.
-  Using 'no signal' or 'POWER ONLY' or the others, check 
the back light on.
▪ Auto adjustment Map(using RS-232C to USB cable)
RS-232C COMMAND
[CMD  ID  DATA]
  Wb 
00  00 
White Balance Start
  Wb 
00  ff 
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and 
adjust  other  two  lower  than  C0.(When  R/G/B  Gain  are  all 
C0, it is the FULL Dynamic Range of Module)
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪  Enter  White  Balance  by  pushing  "►"  key  at  "9.  White 
Balance".
* CASE Cool Mode
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).B.
1) x, y > target
2) x, y < target
3) x >target, y < target
4) x < target, y > target
   -  Every 4 case have to fit y value by adjusting B Gain 
and then fit x value by adjusting R-Gain.
   -  In  this  case,  increasing/decreasing  of  B  Gain  and  R 
Gain can be adjusted.
How to adjust
1) In case G gain more than 172
    Adjust R Gain and B Gain less than 192 
2) if the G gain value be adjusted down to 172
     One of the R/B Gain is 254
3)  if G Gain is 172, More than one of R/B Gain is to be 
between 192~254.
* CASE Medium / Warm
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).
1) x, y > target
i) Decrease the R, G. 
2) x, y < target
i) First decrease the B gain, 
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
4) x < target, y > target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
*  After you finished all adjustments, Press "In-start" key and 
compare Tool option and Area option value with its BOM, if 
it  is  correctly  same  then  unplug  the AC  cable.  If  it  is  not 
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
*  Push  the  "IN  STOP"  key  after  completing  the  function 
inspection. And  Mechanical  Power  Switch  must  be  set 
“ON”.
4.3. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool Mid Warm
R Gain jg
Ja
jd
00
172
192 192
254
G Gain jh
Jb
je
00
172
192 192
192
B Gain ji
Jc
jf
00
192
192 172
254
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
172
172
192
64
64
64
ON
100
- 14 -
5. HI-POT Test
5.1. HI-POT auto-check preparation
-  Check the POWER cable and SIGNAL cable insertion condition
5.2. HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
-  If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
5.3. Checkpoint
(1) Test voltage
- Touchable Metal : 3 KV / min at 100 mA
- SIGNAL : 3 KV / min at 100 mA
(2) TEST time: 1 second. (case : mass production )
(3) TEST POINT
- Touchable Metal => LIVE & NEUTRAL : Touchable Metal.
- SIGNAL => LIVE & NEUTRAL : SIGNAL.
6. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number
▪  Must check the serial number at the Diagnostics of SET UP menu.
  (Refer to below).
6.1. Signal Table
CMD :  
A0h
LENGTH :  85~94h (1~16 bytes)
ADH :  
EEPROM Sub Address high (00~1F)
ADL :  
EEPROM Sub Address low (00~FF)
Data :  
Write data
CS :  
CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay :  
20ms
6.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal,  V_Frequency,  Sync_Polarity,  Htotal,  Hstart,  Vstart,  0, 
Phase
Data write : Model Name and Serial Number write in EEPROM,.
6.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced in 
production  line,  because  serial  number  D/L  is  mandatory  by 
D-book 4.0.
* Manual Download(Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, sometimes 
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need 
Manual download.
1) Press the "Instart" key of Adjustment remote control.
2) Go to the menu "6.Model Number D/L" like below photo.
3)  Input  the  Factory  model  name(ex  32LN520B-ZA)  or  Serial 
number like photo.
4)  Check the model name Instart menu → Factory name displayed 
(ex 32LN520B-ZA)
5)  Check  the  Diagnostics  (DTV  country  only)  →  Buyer  model 
displayed (ex 32LN520B-ZA)
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
- 15 -
7. MAC Address & CI+ key download
7.1 MAC Address 
7.1.1 Equipment & Condition
▪ Play file : Serial.exe
▪ MAC Address edit
▪ Input Start / End MAC address 
7.1.2 Download method
(1) Communication Prot connection
Connection  :  PCBA  (USB  Port) 
  USB  to  Serial Adapter 
(UC-232A) 
 RS-232C cable 
 PC(RS-232C port) 
* Caution :  LJ21*  chassis  support  only  UC-232A  driver.  (only 
use this one. ) 
(2) MAC Address(Not use) & CI+ Key Download
▪  Set CI+ Key path Directory at Start Mac & CI+ Download 
Programme
▪ Com 1,2,3,4 and 115200(Baudrate)
▪ Port connection button click(1)
▪ Push the (2) MAC Address write.
▪ At success Download, check the OK (3)
▪ Start CI+ Key Download, Push the (4)
▪ Check the OK or NG
GP4_LOW
- 16 -
■ Screw specification and application situation
<Warning>
Check Screw Type When Screw is assembled at 'A' Part. If 'B' Screw is used at the 'A' 
part, Module will get damaged.
SCREW ASSEMBLY WORKING GUIDE
FAB31339403
(M3*L6, BK, Machine)
4EA
FAB31639801
(M4*L10, BK, Taptite)
9EA
FAB30016124 
(M4*L14, BK, Machine)
2EA
C
C
A
A
B
B
B
A
A
A
A
A
B
A
A
Page of 75
Display