LG 32LM6400 (CHASSIS:LT22E) Service Manual ▷ View online
- 16 -
4.5. ADC Calibration : Comp 480i/Comp 1080p/RGB
1) Press “ADJ” key on R/C for adjustment.
2) Enter Password number. Password is “0 0 0 0”.
3) Move to the “8. ADC Calibration” by using ▲/▼(CH +/-) and
press ENTER(►).
4) Move to the “ADC Type” by using ▲/▼(CH +/-)
5) Press the right direction key(►) to ADC Type “OTP”.
6) Press the right direction key(►) to Start.
7) After about a few seconds, appear “ADC Calibration
Completed”, then complete
4.5.2. ADC Calibration - Manual
※
Required Equipments
▪ Remote controller for adjustment
▪ MSPG-925F/MSPG-1025/MSPG-3233 Pattern Generator
4.5.2.1. Process
1) Change the Input to Component1 or 2 mode..
2) Input the Component 480i@60Hz 100% Color Bar YPbPr
signal into Component1 or 2.
(MSPG-925F 480i Model: 209 / Pattern: 65 )
(MSPG-925F 1080p Model: 225 / Pattern: 65 )
[Fig. 2]
3) Press “ADJ” key on R/C for adjustment.
4) Enter Password number. Password is “0 0 0 0”.
5) Move to the “8. ADC Calibration” by using ▲/▼(CH +/-) and
press ENTER(►).
6) Move to the “ADC Type” by using ▲/▼(CH +/-)
7) Press the right direction key(►) to ADC Type “External”.
8) Press the right direction key(►) to Start.
9) After about a few seconds, appear “ADC Calibration
Completed”, then complete.
10) Change input source component 1080p, Do 3)~9) steps.
11) Change input source RGB 1080p and Do 3)~9) steps.
4.6. Check SW Version
4.6.1. Method
1) Push In-star key on Adjust remote-controller.
2) SW Version check(ex. 47LW9800-DA)
5. SET assembly adjustment method
5.1. Input Area-Option
(1) Profile : Must be changed the Area option value because
being different of each Country’s Language and
signal Condition.
(2) Equipment : adjustment remote control.
(3) Adjustment method
- The input methods are same as other chassis.(Use IN-START
Key on the Adjust Remocon.)
Refer to Job Expression of each main chassis ass’y
(EBTxxxxxxxx) for Option value
5.2. Adjustment of White Balance
● In case of keeping module is in the circumstance of 0°C, it
should be placed in the circumstance of above 15°C for 2
hours
● In case of keeping module is in the circumstance of below
-20°C, it should be placed in the circumstance of above 15°C
for 3 hours.
IN START
Model Name
: 47LW9800-DA
1.Adjust Check ▶
Adjust Check
Serial Number
: 012PTED6N500
2.ADC Date
1. Country Group
(Press OK to Save)
S/W Version
: 3.02.06.01
3.Power Off Status
Country Group Code
10
MICOM Version
: 3.05.3
4.System1
Country Group
TW
BOOT Version
: 1.02.22
5.System2
Country
TW/CB/PA
FRC Version
: 1.50
6.Model Number D/L
2. Tool Option
IR LED Version
: c8
7.Test Option
Tool Option1
33112
EDID(RGB/HDMI)
: 0.03/0.02
8.External ADC
Tool Option2
5461
Chip Type
: BCM35230
9.Spread Spectrum
Tool Option3
3327
Wireless Host Ver.
: 0.00.0
10.Sync Level
Tool Option4
17593
Wireless B/B Ver.
: 0.00.0
11.Wireless Ready
Tool Option5
47695
Wi-Fi Version
:1.0
12.Stable Count
Tool Option6
697
Wi-Fi Channel
:0
13.ODC Test
3. Adjust White Balance :
OK
Wi-Fi MAC
:00:00:00:00:00:00
14.Local Dimming
4. Adjust ADC :
OTP
MAC Address
:FF:FF:FF:FF:FF:FF
15.SDP Server Selection
480i Component
OK
Widevine
:LGTV10L000011618
16. Network Error History
1080p Component
OK
Local Dimming Ver.
:0x0707
RGB
OK
Formatter Version
: 0.6c
5.EDID :
OK
RF Receiver Version
:
RGB
OK(0x98)
Debug Status
: Release
HDMI1
OK(0x7F,0xCB)
HDMI2
OK(0x7F,0xBB)
UTT : 40
HDMI3
OK(0x7F,0xAB)
APP History Ver. : 35190
HDMI4
OK(0x7F,0x9B)
PQL DB : LGD_AF_LGT10_xxxxxx
- 17 -
▪ Purpose : Adjust the color temperature to reduce the deviation
of the module color temperature.
▪ Principle : To adjust the white balance without the saturation,
Fix the one of R/G/B gain to 192 (default data) and
decrease the others.
▪ Adjustment mode : Three modes – Cool / Medium / Warm
※
Required Equipment
▪ Remote controller for adjustment
▪ Color Analyzer : CA100+ or CA-210 or same product (should
be used in the calibrated ch by CS-1000)
- LCD TV : CH-9
- PDP TV : CH-10
- White LED TV : CH-14
- RGB LED(MNT) : CH-16
- Auto W/B adjustment instrument(only for Auto adjustment)
5.2.1. Adjustment of White Balance :
(For Automatic Adjustment)
Connecting diagram of equipment for measuring (For
Automatic Adjustment)
1) Set TV in adj. mode using POWER ON key
2) Zero calibrate probe then place it on the center of the
Display
3) Connect Cable(RS-232C)
4) Select mode in adj. Program and begin adj.
5) When adj. is complete (OK Sing), check adj. status pre
mode(Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adj.
▪ W/B Adj. must begin as start command “wb 00 00” , and
finish as end command “wb 00 ff”, and Adj. offset if need
※
Luminance min value is 150cd in the Cool/Medium/Warm
mode( For LCD)
5.2.2. Adjustment of White Balance (for Manual adjustment)
▪ Color analyzer(CA100+, CA210) should be used in the
calibrated ch by CS-1000
▪ Operate the zero-calibration of the CA100+ or CA-210, then
stick sensor to the module when adjusting.
▪ For manual adjustment, it is also possible by the following
sequence.
1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 15 minutes.
(If not executed this step, the condition for W/B may be
different.)
2) Push “Exit” key.
3) Change to the AV mode by remote control.
4) Input external pattern (80% white pattern)
5) Push the ADJ key => Enter “0000” (Password)
6) Select “3. W/B ADJUST”
7) Enter the W/B ADJUST Mode
8) Stick the sensor to the center of the screen and select each
items (Red/Green/Blue Gain and Offset) using ▲/▼(CH +/-)
key on R/C..
9) Adjust R/ G/ B Gain using ◄/►(VOL +/-) key on R/C.
10) Adjust three modes all (Cool / Medium / Warm) : Fix the
one of R/G/B gain and change the others
11) When adjustment is completed, Enter “COPY ALL”
12) Exit adjustment mode using EXIT key on R/C.
※
CASE
First adjust the coordinate far away from the target value(x, y).
(1) x, y >target
i) Decrease the R, G.
(2) x, y < target
i) First decrease the B gain,
ii) Decrease the one of the others.
(3) x >target , y< target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
(4) x < target , y >target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
● Standard color coordinate and temperature when using the
CA100+ or CA210 equipment
Change reason : When vivid mode, more detail than other
company set.
Color coordinate
Mode
X
Y
Temp
△uv
Cool
0.269±0.002
0.273±0.002 13000K
0.0000
Medium 0.285±0.002
0.293±0.002 9,300 K 0.000
Warm
0.313±0.002
0.329±0.002 6,500K 0.003
- 18 -
● In case of Edge LED module, the color coordinates is
changing by aging, so you have to use the below table.
The Time Table of color coordinates by SET Aging Time
GP3
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
269
273
285
293
313
329
1
0 ~ 2
279
288
295
308
319
338
2
3 ~ 5
278
286
294
306
318
336
3
6 ~ 9
277
285
293
305
317
335
4
10 ~19
276
283
292
303
316
333
5
20 ~ 35
274
280
290
300
314
330
6
36 ~ 49
272
277
288
297
312
327
7
50 ~ 79
271
275
287
295
311
325
8
80 ~ 149
270
274
286
294
310
324
9
Over 150
269
273
285
293
309
323
■ In the SET applied LED module (LS5700/LM6200/LM6600/
LM7600 Series), cause of the physical characteristics of
LED Module, sets are taken a 120 minutes by aging time
to stabilize a color coordinates. So White Balance Control
equipments have to get the SET Aging Time from the SET
and then going to control the W/B by revise color coordinates
at each time
- To check the Coordinates of White Balance, you have to
measure at the below conditions.
Picture Mode : select Vivid and change
Dynamic Contrast : Off ,
Dynamic Colour : Off,
Clear White : Off
->Picture Mode change : Vidid -> Vivid(User)
(If you miss the upper condition, the coordinates of W/B can be
lower than the spec.)
5.3. Intelligent Sensor Inspection Guide
Step 1. Turn on the TV set.
Step 2. Press “EYE” button on the Adjustment remote controller.
Step 3. Block the Intelligent Sensor module on the front C/A
about 6 seconds.
When the “Sensor Data” is lower than 20, you can see the
“OK” message -> If it doesn’t show “OK” message, the Sensor
Module is defected one.
You have to replace that with a good one.
Step 4. After check the “OK” message come out, take out your
hand from the Sensor module.
-> Check “Sensor Data” value change from “0” to “300” or not.
If it doesn’t change the value, the sensor is also defected
one. You have to replace it.
5.4. LAN Inspection
1) LAN Port connection with PCB
2) Network setting at MENU Mode of TV
3) Setting automatic IP
4) Setting state confirmation
5) If automatic setting is finished, you confirm IP and MAC
Address
Green Eye-Check
Sensor Data : 492
BackLight : 100
OK
- 19 -
5.5. WIDEVINE Key Inspection
1) Confirm Key input Data at the “IN START” MENU Mode
5.6. Model name & Serial number D/L
5.6.1. Notice
1) Serial number D/L is using of scan equipment.
2) Setting of scan equipment operated by Manufacturing
Technology Group.
3) Serial number D/L must be conformed when it is produced in
production line, because serial number D/L is mandatory by
D-book 4.0
4) Check the model name In-start menu -> Factory name
displayed (ex 32LS5700-DA)
5) Check the Diagnostics (DTV country only) -> Buyer model
displayed (ex 32LS5700-DA)
5.6.2. Method : Auto
1) Press “Power on” key of service remocon.(Baud rate : 115200
bps)
2) Connect RS232 Signal Cable to RS-232 Jack
3) Write Serial number by use RS-232.
4) Must check the serial number at Instart menu
5.6.3. Method : Manual
* If the TV set is downloaded By OTA or Service man, Sometimes
model name or serial number is initialized.
( Not always) It is impossible to download by bar code scan, so
It need Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘6.Model Number D/L’ like below photo.
3) Input the Factory model name or Serial number like photo.
5.7. Wi-Fi MAC ADDRESS CHECK
5.7.1. Notice
1) Using RS232
Command
Set ACK
Transmission [A][l][][Set ID][][20][Cr]
[O][K][x] or [N][G]
2) Check the menu on in-start
5.8. Local Dimming Inspection
5.8.1. Edge LED models with local dimming
1) Press ‘TILT” key of the Adj. R/C and check moving pat-
terns. The black bar patterns moves from left to right. If local
dimming function does not work, a whole screen shows full
white.
No
Item
Vallue Unit
Remark
1.
Dielectric
Voltage(AC<->FG)
1.5
kV
At 100mA for
1sec(Line)
1.5
At 100mA for
1min(OQC)
2.
Dielectric
Voltage(Without FG)
3
kV
At 100mA for
1sec(Line)
3
At 100mA for
1min(OQC)
Click on the first or last page to see other 32LM6400 (CHASSIS:LT22E) service manuals if exist.