DOWNLOAD LG 32LG5600 (CHASSIS:LD85D) Service Manual ↓ Size: 6.27 MB | Pages: 27 in PDF or view online for FREE

Model
32LG5600 (CHASSIS:LD85D)
Pages
27
Size
6.27 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
32lg5600-chassis-ld85d.pdf
Date

LG 32LG5600 (CHASSIS:LD85D) Service Manual ▷ View online

- 13 -
* Auto adjustment Map (RS-232C)
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA-210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically. (80~100°).
3) Aging time  
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
8.1. Auto white Balance
(set:RS-233 Host:PC, Baud Rate:115200bps, Download:Cortez)
: Inside pattern is used when white balance is controlled.
Connect as below figure and click the start button on W/B
execution program. W/B is automatically processing
Cool_Medium_Warm in order. 
When W/B is completed, you can see ‘OK’ on PC monitor.
8.2. Manual white Balance 
- One of R Gain / G Gain / B Gain should be kept on 80, and
others  are controlled lowering from 80 
1) Press ‘power on’ of the control R/C, set heat run to white by
pressing 
G
, and heat run over 15 minutes. (Set : RS-233
Host : PC, Baud Rate : 115200bps, Download : Cortez)
2) Zero Calibrate CA-210, and when controlling, stick the
sensor to the center of LCD module surface.
3) Double click In-start key on Controlling R/C and get in ‘white
balance’.
4) Set test-pattern on and display inside pattern. Control is
carried out on three color temperature, COOL, MEDIUM,
WARM. (Control is carried out three times,)
5) When the R/G/B GAIN is 80 on OSD, it is the FULL
DYNAMIC Range of the Module. In order to control white
balance without the saturation of FULL DYNAMIC Range
and DATA, one of R Gain / G Gain / B Gain should be kept
on 80, and other two is controlled lowering from 80.
* Color Temperature: Cool, Medium, Warm
1) When R GAIN is set to 80
- Control G GAIN and B GAIN by lowering from 80. 
2) When B GAIN is set to 80
- Control R GAIN and G GAIN by lowering from 80.
3) When G GAIN is set to 80
- Control R GAIN and B GAIN by lowering from 80.
One of R Gain / G Gain / B Gain should be kept on 80,
and adjust other two lower than 80.
(When R/G/B GAIN are all 80, it is the FULL DYNAMIC
Range of Module)
9. Set information(Serial No & Model name)
(1) Setting up like bottom figure (After setting white balance,
this is set)
(Setting : Press IN-START key in the Adjust remote control.
Select “System Control 2” by using 
D
/
E
(CH+/-) key, and
press 
A
(ENTER). Using Adjust remote control, RS-232
Host & Baud Rate & Download value change
RS-232 Host:PC, Baud Rate:115200bps, Download:Cortez)
(2) Bar-code scanning
1) Push the menu button in DTV mode. 
Select the SETUP -> Diagnostics -> To set
2) Check the Serial Number.
Type
LD82D
Baud Rate
Data bit
Stop bit
Parity
115200
8
1
None
Index
Cmd 1 Cmd 2 Data Min Value
Max Value
R-Gain_Normal
j
a
00(00)
128(80)
G-Gain_Normal
j
b
00(00)
128(80)
B-Gain_Normal
j
c
00(00)
128(80)
R-Gain_Warm
j
d
00(00)
128(80)
G-Gain_Warm
j
e
00(00)
128(80)
B-Gain_Warm
j
f
00(00)
128(80)
R-Gain_Cool
j
g
00(00)
128(80)
G-Gain_Cool
j
h
00(00)
128(80)
B-Gain_Cool
j
i
00(00)
128(80)
R-Offset_Normal
l
j
00(00)
128(80)
G-Offset_Normal
l
k
00(00)
128(80)
B-Offset_Normal
l
l
00(00)
128(80)
R-Offset_Warm
l
m
00(00)
128(80)
G-Offset_Warm
l
n
00(00)
128(80)
B-Offset_Warm
l
o
00(00)
128(80)
R-Offset_Cool
l
p
00(00)
128(80)
G-Offset_Cool
l
q
00(00)
128(80)
B-Offset_Cool
l
r
00(00)
128(80)
w
b
00
Starting W/B ADJ
w
b
10
Using internal Pattern
w
b
ff
Ending W/B ADJ
- 14 -
TROUBLESHOOTING
1. Power Board 
1-1. The full flowchart for the voltage output
Start check
Manufacture’s model
passage
1. Check the Power Off
status.
Does the whole
screen appear?
Is it 
identical to when the
power is off?
No
Yes
No
Yes
Yes
Yes
Yes
2. Check the Interface
signal status.
Is the Interface 
signal operating?
Yes
3. Check the St-by 5V
signal circuit.
Does the 
low pressure output
appear?
Does the 
St-by 5V signal 
appear?
No
No
Yes
4. Check the 5V Monitor
signal circuit.
Does the 
5V Monitor signal 
appear?
No
7. Check the VSC Vs-ON
signal 
Does the 
high tension output
appear?
Does the 
VSC signal Vs-ON
appear?
No
No
Does the
high tension 
output voltage
occur?
When
removing  the Y B/D
Module input connector,
does output voltage
drop?
When the
Y, Z B/D Module
input connector, does Power
Board high tension 
output voltage
drop?
No
No
No
9. Check the Power
Board Output high
tension circuit
Yes
10. Check the Z B/D
Module output circuit
Yes
When 
removing the Z B/D
Module input connector,
does output voltage
drop?
11. Check the Y B/D
Module output circuit
Yes
Yes
8. Check the Vs, Va
voltage output circuit.
Does the 
Vs, Va voltage output
appear?
No
Yes
Yes
5. Check the VSC RL-ON
signal.
Does the 
VSC signal RL-ON
appear?
No
6. Check the VSC low
pressure output
Does the 
VSC low pressure
output appear?
No
- 15 -
2. No Power
(1) Symptom
1) Does not  minute discharge at module. 
2) Non does not come into the front LED. 
(2) Procedure check
Is the power cord plugged in?
Plug in the power cord.
Yes
No
Is the Line Filter and Power
Board Cable connected?
Connect the Cable.
Yes
No
Is the appropriate Fuse(F101) on
the Power Board?
Replace the Fuse.
Yes
No
Is the Power Board and 13P of
VSC Board Cable connected?
Connect the Cable.
Yes
No
After removing the cables, connect them to the Power Board(except the
SC101 connection cable), and change the AC voltage marking to manual.
When ST-BY 5V does not operate, replace the Power Board.
- 16 -
3. Protect Mode
(1) Symptom
1) After lighting up once, it does not discharge minutely from module.
2) The rely falls.(there is an audible “click”) 
3) The color of the front LED turns from green to red.
(2) Procedure check
Is the Power Board
normal ?
Replace the Power Board.
Is the output Low/High voltage normal
except for Stand-by 5V?
Yes
No
No
Is the each connector
normal?
Replace the connector.
Replace the 
Y-Board.
After connecting each connector do
they operate normally? 
Yes
No
Yes
Is the Ctrl Board
normal?
Replace the 
X-Board.
Is the output voltage normal after
removing P1, 2, 4, 9, 10 connectors of
the Ctrl-B/D?
Yes
No
Yes
Is the Y-Board
normal?
Is the output voltage
normal after removing
P103 connector of 
Y-B/D?
Is the appropriate Fuse(FS101,FS102)
on the Y-B/D normal?(Replace if open)
Yes
No
Yes
Yes
Replace the 
Z-Board.
Is the Z-Board
normal?
Is the output voltage
normal after removing
P1 connector of
Z-B/D?
Is the appropriate Fuse (FS1, FS2) on
Z-B/D? (replace if open)
Yes
No
Yes
Is the X- Board
normal?
Is the output voltage normal after
removing P1, 2, 3, 4, 5 connectors of
the X-B/D?
If the output voltage is normal after removing
the P1, P2, P3 : Replace the right X-B/D
If the output voltage is normal after removing
the P4, P5 : Replace the left X-B/D
Yes
No
Yes
Is the 
VSC Board normal?
Is the output voltage normal after
removing P900, P901 of VSC Board?
After a COF crisis for each board, check the normal operation. For normal operation,
corresponding COF failure means the module should be relaced.
If it operates normally after removing the
P900, P901 : Replace the VSC Board
Yes
No
Is the COF of X, Y, Z
normal ?
No
Yes
Yes
Page of 27
Display