              - 13 -                                                         
 
   
 
 
2.  EDID DOWNLOAD 
 
2-1. Panel Setting 
 
a) 
You should change the panel size by going to the Factory Mode, press “Menu”, “1”, “2”, “4”, 7” 
and “5” keys on a remote. 
b) 
You have to select 32” or 37”, 42”, 47” panel in Factory mode. 
 
32LE5400-ZA : Panel Select  “LC320EUH_SCAx” 
32LE5700-ZC : Panel Select  “LC320EUH_SCAx” 
32LE5750-ZC : Panel Select  “LC320EUH_SCAx” 
37LE5400-ZA : Panel Select  “LC370EUH_SCAx” 
42LE5400-ZA : Panel Select  “LC420EUH_SCAx” 
42LE5700-ZC : Panel Select  “LC420EUH_SCAx” 
42LE5750-ZC : Panel Select  “LC420EUH_SCAx” 
47LE5400-ZA : Panel Select  “LC470EUH_SCAx” 
 
 
2-2. EDID Setting 
 
a) 
You should change the panel size by going to the Factory Mode, press “Menu”, “1”, “2”, “4”, 7” 
and “5” keys on a remote. 
b) 
You have to select “Engineering Menu” in Factory mode. 
c) 
Enter “ EDID Download” by pushing “OK” key. 
 
Factory mode  Engineering menu  EDID Download select
 
 
              - 14 -                                                         
 
   
 
2-3. PC EDID Table 
00 FF FF FF FF FF FF 00 1E 6D
 
 
01 
 
03 80 46 28 78 2A
C0
0B
A3
57 49 9C
25 
11 47 4A A1
08 00 31 40 45 40 61 40 D1 C0 81 80 
01 01 01 01 01 01 26 36 80 A0
70 38 1F 40 30 20 
25 00 BA 88 21 00 00 1A
16 21 50 A0
51 00 1E 30 
48 88 35 00 BA 88 21 00 00 1E 00 00 00 FD 00 39 
3E 1E 53 10 00 0A 20 20 20 20 20 20 
 
 01 
 
 
2-4. HDMI EDID Table 
00 FF FF FF FF FF FF 00 1E 6D
 
 
01 
 
03 80 46 28 78 2A
C0
0B
A3
57 49 9C
25 
11 47 4A A1
08 00 31 40 45 40 61 40 D1 C0 81 80 
01 01 01 01 01 01 02 3A
80 18 71 38 2D 40 58 2C
45 00 BA 88 21 00 00 1E 16 21 50 A0
51 00 1E 30 
48 88 35 00 BA 88 21 00 00 1E 00 00 00 FD 00 3A
3E 1E 53 10 00 0A 20 20 20 20 20 20 
 
 01 
 
02 03 23 F1 4E 90 1F 20 22 11 05 14 04 13 12 03 
02 15 01 23 09 17 07 83 01 00 00 
 
 
2D 01 1D 00 72 51 D0
1E 20 6E 28 55 00 BA
88 21 00 00 1E 8C 0A
D0
8A
20 E0 2D
10 10 3E 96 
00 BA 88 21 00 00 18 02 3A
80 18 71 38 2D 40 58 
2C 45 00 BA
88 21 00 00 1E 01 1D
80 18 71 1C
16 
20 58 2C 25 00 BA 88 21 00 00 9E 00 00 00 00 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 43 
 
  Detail EDID Options are below 
 
Product ID 
Model Name 
HEX 
EDID table 
DDC Function 
FHD Model 
0001 
01 00 
Analog / Digital 
 
Serial No: Controlled on production line. 
 
Month, Year: Controlled on production line: 
ex) Monthly : ‘03’ -> ‘03’ 
Year : ‘2010’ -> ‘13’ 
 
Model Name(Hex) : 
Model 
MODEL NAME (HEX) 
All 
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 
 
Checksum : Changeable by total EDID data. 
 
Vendor Specific(HDMI) 
INPUT 
MODEL NAME (HEX) 
HDMI 1 
67030C001000B82D 
HDMI 2 
67030C002000B82D 
HDMI 3 
67030C003000B82D 
HDMI 4 
67030C004000B82D 
              - 15 -                                                         
 
   
 
 
3.  FRC DOWNLOAD 
 
a) 
You should change the panel size by going to the Factory Mode, press “Menu”, “1”, “2”, “4”, 7” 
and “5” keys on a remote. 
b) 
You have to select “Engineering Menu” in Factory mode. 
c) 
Enter “ FRC Download” by pushing “OK” key. 
 
Factory mode  Engineering menu  DRC Download select
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
              - 16 -                                                         
 
   
 
 
4.  V-COM Adjust(Only LGD Module) 
 
a)  Why need Vcom adjustment? 
 The Vcom (Common Voltage) is a Reference Voltage of Liquid Crystal Driving. 
 Liquid Crystal need for Polarity Change with every frame. 
 
b)  Adjust sequence 
 You should change the panel size by going to the Factory Mode, press “Menu”, “1”, “2”, “4”, 7”   
and “5” keys on a remote. 
 You have to select “Miscellaneous” in Factory mode. 
 Enter “ V-Com” by pushing “OK” key. 
 
 
 
 As pushing the right or the left key on the remote control, and find the V-COM value which is no   
or minimized the Flicker.   
(If there is no flicker at default value, Press the exit key and finish the VCOM adjustment.) 
 
 
 
[LED/LCD Panel VCOM SPEC .] 
 
 
                      ■ Push the “OK” key to store value. Then the message “Saving OK” is pop. 
 
 
 
 
 
 
 