LG 32LD450 / 32LD450N / 32LD455 / 32LD458 (CHASSIS:LD01B) Service Manual ▷ View online
- Auto Download
• After enter Service Mode by pushing “ADJ” key,
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
* Edid data and Model option download (RS232)
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Never connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2
1) FHD RGB EDID data
2) FHD HDMI EDID data
* Detail EDID Options are below
ⓐ Product ID
ⓑ Serial No: Controlled on production line.
ⓒ Month, Year: Controlled on production line:
ex) Monthly : ‘02’ -> ‘02’
Year : ‘2009’ -> ‘13’
ⓓ Model Name(Hex):
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
Model Name
HEX
EDID Table
DDC Function
FHD Model
0001
01 00
Analog/Digital
- 13 -
MODEL
MODEL NAME(HEX)
all
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
Item CMD1 CMD2 Data0
Download
A
A
0
0
When transfer the ‘Mode In’,
‘Mode In’
Carry the command.
Download
A
E
00 10 Automatically Download
(The use of a internal pattern)
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
INPUT
MODEL NAME(HEX)
HDMI1 67030C001000B82D
HDMI2 67030C002000B82D
HDMI3 67030C003000B82D
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
ⓐ
ⓑ
10
ⓒ
01
03
68
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
80
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
02
3A
80
18
71
38
2D
40
58
2C
40
45
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1E
53
10
00
0A
20
20
20
20
20
20
ⓓ
70
ⓓ
00
ⓔ
80
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
90
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
A0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
B0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
C0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
D0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
E0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
F0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
ⓐ
ⓑ
10
ⓒ
01
03
80
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
80
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
02
3A
80
18
71
38
2D
40
58
2C
40
45
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1E
53
10
00
0A
20
20
20
20
20
20
ⓓ
70
ⓓ
01
ⓔ
80
02
03
26
F1
4E
10
1F
84
13
05
14
03
02
12
20
21
90
22
15
01
26
15
07
50
09
57
07
ⓕ
A0
ⓕ
E3
05
03
01
01
1D
80
18
71
1C
16
20
58
2C
B0
25
00
7E
8A
42
00
00
9E
01
1D
00
80
51
D0
0C
20
C0
40
80
35
00
7E
8A
42
00
00
1E
02
3A
80
18
71
38
D0
2D
40
58
2C
45
00
7E
8A
42
00
00
1E
66
21
50
B0
E0
51
00
1B
30
40
70
36
00
7E
8A
42
00
00
1E
00
00
F0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
F9
- 14 -
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
by D-book 4.0.
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
No. Adjust
mode
CMD(hex)
LENGTH(hex)
Description
1
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
Row Li ne
Column Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
Driv
e
IC
So urce D r i v e I C
Circuit Block
Ti m i n g
Co nt r o ll e r
Co nt r o ll e r
Po w e r
Blo ck
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
Con t rol si gnal
In
te
te
r
fa
c
e
TFT
Po w e r I n p u t
Power Input
Da t a I n p u t
Da t a I n p u t
V
COM
Liquid
Crys tal
Crys tal
V
COM
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-ZA) or Serial
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-ZA) or Serial
number like photo.
4) Check the model name Instart menu -> Factory name
displayed (ex 42LD450-ZA)
5) Check the Diagnostics (DTV country only) -> Buyer model
displayed (ex 42LD450)
- 15 -
- 16 -
BLOCK DIAGRAM
Click on the first or last page to see other 32LD450 / 32LD450N / 32LD455 / 32LD458 (CHASSIS:LD01B) service manuals if exist.