DOWNLOAD LG 26LN45XX / 26LN4505 (CHASSIS:LC31A / LD31T) Service Manual ↓ Size: 6.86 MB | Pages: 33 in PDF or view online for FREE

Model
26LN45XX 26LN4505 (CHASSIS:LC31A LD31T)
Pages
33
Size
6.86 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
26ln45xx-26ln4505-chassis-lc31a-ld31t.pdf
Date

LG 26LN45XX / 26LN4505 (CHASSIS:LC31A / LD31T) Service Manual ▷ View online

- 11 -
3.1. EDID Process
3.1.1. EDID download
(1) Press "Power only" key of service remote control.
(2) Press the ADJ KEY on R/C and enter EZ ADJUST
(3)  Enter EDID D/L mode by pushing "►" key at "11. EDID D/L".
(4) EDID download is executed automatically.
(5) Press EXIT key on service remote control.
<Caution>
-  Never connect HDMI & D-sub Cable when download EDID.
-  Download HDMI
* Edid data and Model option download (USB)
3.1.2. RGB EDID Data
(1) All models without 29MN33D(Product ID: 22984/HEXA: 59C8)
*(week), **(year), ***(Check sum) : Adjustable Data
: Screen size, 
: Color Characteristics
3.1.3. HDMI EDID Data
(1) All models(Product ID: 22986/HEXA:59CA)
*(week), **(year), ***(Check sum) : Adjustable Data 
**** (physical address): (HDMI : 10), ****(Check sum): (HDMI : CE)
: Screen size, 
: Color Characteristics
3.2. Function Check
3.2.1. Check display and sound
*Check Input and Signal items. (cf. work instructions) 
1) TV
2) AV (SCART/CVBS)
3) COMPONENT (480i)
4) RGB(PC : 1366 x 768 @ 60Hz)
5) HDMI(PC : 1366 x 768 @ 60Hz)
6) PC Audio In 
* Display and Sound check is executed by Remote control
<Caution>  Not to push the INSTOP key after completion if the 
function inspection.
3.3. CI+ key writing process. (Device CN)
3.3.1. Communication Port Connection
Connection  :  PCBA  (USB  Port)  →  USB  to  Serial Adapter 
(UC-232A) → RS-232C cable → PC(RS-232C port) 
* Caution:  LD31Q/LD31A  chassis  support  only  UC-232A 
driver. (only use this one)
3.3.2. CI+ Key Download
(1)  Set CI+ Key path Directory at Start Mac & CI+ Download 
Programme.
(2) Set COM 1,2,3,4 / 115200(Baudrate) (1)/(2)
(3) Click port connection button(1)
(4) Start CI+ Key Download, Push the button(4)
(5) Check OK or NG
(6)  After  completing  download,  CI  +  key  values  are  increase 
by one automatically. To write CI+ key next SET, click CI+ 
key writing button(5) directly.
(7)  Check whether the key was downloaded or not at ‘In Start’ 
menu. (Refer to below).
NO
Item
CMD 1 CMD 2 Data 0
Enter download 
MODE
Download 
‘Mode In’
A
A
0
0 When transfer the ‘Mode 
In’, Carry the command.
EDID data and 
Model option 
download
Download
A
E
00 10 Automatically download
(The use of a internal Data)
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option6
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB 
11. Test Pattern  
12. EDID D/L 
 
14. Touch Sensitivity Setting
15. Ext. Input Adjust
16. SPK Lipsync Adjust
17.SPDIF Lipsync Adjust
EDID D/L
  HDMI 
OK
  RGB 
OK
Start
Reset
- 12 -
=> Check the Download to CI+ Key value in LG set.
(1) Check the method of CI+ Key value
1) Check the method on Instart menu
2) Check the method of RS232C Command 
a. Into the main ass’y mode(RS232: aa 00 00)
b. Check the key download for transmitted command
         (RS232: ci 00 10)
c. Result value
- Normally status for download : OKx
- Abnormally status for download : NGx
(2) Check the method of CI+ key value(RS232)
1) Into the main ass’y mode(RS232: aa 00 00)
2) Check the mothed of CI+ key by command
    (RS232: ci 00 20)
3) Result value
i 01 OK 1d1852d21c1ed5dcx
4. Total Assembly line process
4.1. Tool option & ADC Check
(1) Press "Power on" key of service remote control.
(2)  Connect USB Port → USB to Serial Adapter (UC-232A) → 
RS-232C cable → PC(RS-232C port)
(3)  Check the 'Tool Option'(Refer to the BOM Comments or 
Adjustment spec) 
(4)  Check the ‘ADC’ is ok.
4.2. Model name & Serial number download
4.2.1. Model name & Serial number D/L
 
1) Press "Power on" key of service remote control.
2) Connect RS232 Signal Cable to RS-232 Jack.
3) Write Model Name & Serial Number by use RS-232.
4)  Must check the serial number at the Diagnostics of SET UP 
menu. (Refer to below.)
4.2.2. Method & notice
(1)  Model Name & Serial Number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced 
in production line, because serial number D/L is mandatory 
by D-book 4.0.
*Manual Download (Model Name and Serial Number)
If  the  TV  set  is  downloaded  By  OTA  or  Service  man, 
Sometimes model name or serial number is initialized. (Not 
always) There is impossible to download by bar code scan, 
so It need Manual download.
1)  Press the 'Instart' key of ADJ remote control.
2)  Go to the menu '6.Model Number D/L' like below photo.
3)  Input  the  Factory  model  name(ex  24LN4500)  or  Serial 
number like photo.
4)  Check  the  model  name  Instart  menu  →  Factory  name 
displayed (ex 24LN4500)
5)   Check  the  Diagnostics  (DTV  country  only)  →  Buyer 
model displayed (ex 24LN4500)
CMD 1
CMD 2
Data 0
A
A
0
0
CMD 1
CMD 2
Data 0
C
I
1
0
CMD 1
CMD 2
Data 0
A
A
0
0
CMD 1
CMD 2
Data 0
C
I
2
0
 
CI+ Key Value
- 13 -
4.3. Function Check
4.3.1. Check display and sound
 Check Input and Signal items. (cf. work instructions) 
1) TV
2) AV (SCART/CVBS)
3) COMPONENT (480i)
4) RGB(PC : 1366 x 768 @ 60Hz)
5) HDMI(PC : 1366 x 768 @ 60Hz)
6) PC Audio In 
* Display and Sound check is executed by Remote control
* Caution :  Not to push the INSTOP KEY after completion if 
the function inspection.
4.3.2. PCMCIA CARD Check
You must adjust DTV 29 Channel and insert PCMCIA CARD 
to socket.
-  If PCMCIA CARD works normally, video signals will appear 
on  screen.  But  it  works  abnormally,  "No  CA  module"  will 
appear on screen.
* Caution: Set up "RF mode" before launching products.
4.3.3. PIP Check
(1) Press “Power on” key of service remote control.
(2) Input RGB & TV(ATV or DTV) signal.
(3) Set Input mode to RGB.
(4) Press ‘PIP” key of ADJ remote control
(5) Check TV Video & Audio signal of Sub picture.
4.3.4 HDMI MHL Function Inspection(HDMI2 Port only)
(1)  Insert  HDMI  cable  for  MHL  function  JIG  connected  to 
HDMI2 port of the SET.
(2)  Check  that  LED  of  JIG  is  green  light  and  check  that  set 
screen is correctly worked.
(3)  If NG situation or other HDMI jack connection, LED of JIG 
is red light and screen is not displayed.
4.4. White balance adjustment
 
- Equipment
(1) Color Analyzer: CA-210 (LED Module : CH 14)
(2)  Adj.  Computer(During  auto  adj.,  RS-232C  protocol  is 
needed)
(3) Adjust Remote control
RGB Gains are fixed data for each model.
Insert  RS-232C  Jack  which  is  connected  with  PC  for  White 
Balance or equivalent device.
→  Total Assembly  line  should  be  check  whether  the  color 
coordinate(x,y) data refer to below table were meet or not.
- Cool Panel
* Note :  x,y coordinates are drifted about 0.007 after 30 mins 
heat-run. So checking color coordinate within 5-min at 
total assembly line, consider x,y coordinates might be 
up to 0.007 than x,y target of each color temperature.
* Note : Manual W/B process using adjusts Remote control.
1) After enter Service Mode by pushing "ADJ" key,
2)  Enter  "White  Balance"  by  pushing  "►"  key  at  "White 
Balance".
*  When  doing Adjustment,  Please  make  circumstance  as 
below.
Color 
Temperature
Cool
13,000
K X=0.276 (±0.03)
Y=0.275 (±0.03)
<Test Signal>
Inner pattern
(204gray,80IRE)
Medium
9,300
K X=0.290 (±0.03)
Y=0.298 (±0.03)
Warm
6,500
K X=0.318 (±0.03)
Y=0.334 (±0.03)
Luminance
(cd/m²)
Cool
Min : 80
K Typ : 110
<Test Signal>
Inner pattern
(204gray,80IRE)
Medium Min : 80
K Typ : 110
Warm
Min : 70
K Typ : 110
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option6
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Touch Sensitivity Setting
15. Ext. Input Adjust
16. SPK Lipsync Adjust
17.SPDIF Lipsync Adjust
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
100
104
192
64
64
64
ON
100
- 14 -
4.5. DPM Operation check
■ Measurement Condition: 100~240V@ 50/60Hz
(1)  Set  Input  to  RGB-PC  and  connect  D-sub  cable  to  set  - 
RGB Mode. 
Set Input to HDMI(with Input Label set to PC) and connect 
HDMI cable to set - HDMI Mode
(2) Cut off H sync or V sync of signal.
(3) Check DPM operation refer to the below table.
■ HDMI DPM Operating condition
- Input Label: HDMI (PC&DVI Mode)
4.6. Model name & SW version & Adjust check
* Press the ‘Instart’ key of ADJ remote control.
4.6.1. Model Name& SW Version Check
1) Check ‘Model Name’. 
2) Check ‘S/W Version’ (Refer to the IC Ver. in the BOM)
4.6.2. Adjust Check
1) Check ‘Country Group’
2) Check ‘Area Option’
3) Check ‘Tool Option’ (Refer to the BOM Comments) 
4) Check ‘Adjust ADC[Comp&RGB]’ is OK.
5) Check ‘EDID[RGB&HDMI]’ is OK.
*  After check all, Press the 'EXIT' key of ADJ remote control to 
go out SVC menu.
4.7.  Outgoing condition Configuration
*  After all function test., press IN-STOP key by SVC Remote 
control. And make Outgoing Condition.
Operating Condition
Sync(H/V) Video LED(SET) Wattage(W)
Power S/W On Sleep mode - 
RGB, HDMI
Off/Off
Off
Amber
1
MHL Cable
HDMI & HDMI to DVI Cable 
DPM
X
O
Page of 33
Display

Click on the first or last page to see other 26LN45XX / 26LN4505 (CHASSIS:LC31A / LD31T) service manuals if exist.