DOWNLOAD LG 26LE5300 / 26LE5310 (CHASSIS:LB01A) Service Manual ↓ Size: 5.96 MB | Pages: 42 in PDF or view online for FREE

Model
26LE5300 26LE5310 (CHASSIS:LB01A)
Pages
42
Size
5.96 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
26le5300-26le5310-chassis-lb01a.pdf
Date

LG 26LE5300 / 26LE5310 (CHASSIS:LB01A) Service Manual ▷ View online

4.5. Auto Download
1) Press Adj. key on the Adj. Remote control.
2) Select EDID D/L menu.
3) By pressing Enter key, EDID download will begin
4) If Download is successful, OK is display, but If Download if
failure, NG is displayed.
5) If Download is failure, Re-try downloads.
* Edid data and Model option download (RS232)
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Never connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2
1) HD RGB EDID data
2) HD HDMI EDID data
* Detail EDID Options are below
ⓐ Product ID
ⓑ Serial No: Controlled on production line.
ⓒ Month, Year: Controlled on production line:
ex) Monthly : ‘02’ -> ‘01’
Year : ‘2010’ -> ‘14’
ⓓ Model Name(Hex):
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
Model Name
HEX
EDID Table
DDC Function
HD Model
0000
00 00
Analog/Digital
- 13 -
MODEL
MODEL NAME(HEX)
all
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
INPUT
MODEL NAME(HEX)
HDMI1 65030C001000011D
HDMI2 65030C002000011D
HDMI3 65030C003000011D
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
a
b
10
c
01
03
68
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
C0
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
66
21
50
B0
51
00
1B
30
40
70
40
36
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1F
46
10
00
0A
20
20
20
20
20
20
d
70
d
00
e
80
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
90
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
A0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
B0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
C0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
D0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
E0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
F0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
a
b
10
c
01
03
80
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
C0
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
66
21
50
B0
51
00
1B
30
40
70
40
36
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1F
46
10
00
0A
20
20
20
20
20
20
d
70
d
01
e
80
02
03
20
F1
4E
10
1F
84
13
05
14
03
02
12
20
21
90
22
15
01
26
15
07
50
09
57
07
f
A0
f
80
18
71
1C
16
20
58
2C
25
00
7E
8A
42
00
B0
00
9E
01
1D
00
80
51
D0
0C
20
40
80
35
00
7E
8A
C0
42
00
00
1E
8C
0A
D0
8A
20
E0
2D
10
10
3E
96
00
D0
7E
8A
42
00
00
18
02
3A
80
18
71
38
2D
40
58
2C
E0
45
00
7E
8A
42
00
00
1E
01
1D
80
D0
72
1C
16
20
F0
10
2C
25
80
7E
8A
42
00
00
9E
00
00
00
00
00
D5
NO
Item
CMD1 CMD2
Data0
Enter
Download
A
A
0
0
When transfer the ‘Mode In’,
download Mode
‘Mode In’
Carry the command.
EDID data
Download
A
E
00 10
Automatically Download
and Model
(The use of a internal pattern)
option download
- 14 -
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-ZA) or Serial
number like photo.
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex) 
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Row  Li ne
Column  Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
 Driv
e
 IC
So urce D r i v e  I C
Circuit Block
Ti m i n g  
Co nt r o ll e r
Po w e r  
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
In
te
r
fa
c
e
TFT
Po w e r  I n p u t
Power Input
Da t a  I n p u t
Da t a  I n p u t
V
COM
Liquid 
Crys tal
V
COM
4) Check the model name Instart menu -> Factory name
displayed (ex 42LD450-ZA)
5) Check the Diagnostics (DTV country only) -> Buyer model
displayed (ex 42LD450)
6. CI+ key download(Only for CI model)
6-1. Download Procedure
(1) Press "Power on" button of a service R/C.(Baud rate :
115200 bps)
(2) Connect RS232-C Signal Cable.
(3) Write CI+ Key through RS-232-C.
(4) Check whether the key was downloaded or not at ‘In Start’
menu. (Refer to below).
=> Check the Download to CI+ Key value in LGset. 
6-2. check the method of CI+ Key value
(1) Check the method on Instart menu
(2) check the method of RS232C Command 
1) into the main ass’y mode (RS232 : aa 00 00)
2) check the key download for transmitted command
(RS232 : ci 00 10)
3) result value
- normally status for download : OKx
- abnormally status for download : NGx
6-3. Check the method of CI+ key value (RS232)
(1) into the main ass’y mode (RS232 : aa 00 00)
(2) Check the method of CI+ key by command
(RS232 : ci 00 20)
(3) Result value
i 01 OK 1d1852d21c1ed5dcx
- 15 -
CMD 1
CMD 2
Data 0
A
A
0
CMD 1
CMD 2
Data 0
C
I
1
CMD 1
CMD 2
Data 0
A
A
0
CMD 1
CMD 2
Data 0
C
I
2
CI+ key Value
- 16 -
BLOCK DIAGRAM
Page of 42
Display