- 13 -
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : 
A0h
LENGTH : 85~94h (1~16 bytes)
ADH 
: EEPROM Sub Address high (00~1F)
ADL 
: EEPROM Sub Address low (00~FF)
Data 
: Write data
CS : 
CMD+LENGTH+ADH+ADL+Data_1+…+Data_n
Delay : 
20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex) 
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Row  Li ne
Column  Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
 Driv
e
 IC
So urce D r i v e  I C
Circuit Block
Ti m i n g  
Co nt r o ll e r
Po w e r  
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
In
te
r
fa
c
e
TFT
Po w e r  I n p u t
Power Input
Da t a  I n p u t
Da t a  I n p u t
V
COM
Liquid 
Crys tal
V
COM
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 32LD322H-ZA) or Serial
number like photo.
4) Check the model name Instart menu -> Factory name
displayed (ex 32LD322H-ZA)
5) Check the Diagnostics (DTV country only) -> Buyer model
displayed (ex 32LD322H)
6. CI+ Key Download method
(1) Download Procedure
1) Press "Power on" button of a service remote control.
(Baud rate : 115200 bps)
2) Connect RS232-C Signal Cable.
3) Write CI+ Key through RS-232-C.
4) Check whether the key was downloaded or not at ‘In
Start’ menu. (Refer to below).
=> Check the Download to CI+ Key value in LGset. 
1. check the method of CI+ Key value
a. check the method on Instart menu
b. check the method of RS232C Command 
1) into the main ass’y mode (RS232 : aa 00 00)
2) check the key download for transmitted command
(RS232 : ci 00 10)
3) result value
- normally status for download : OKx
- abnormally status for download : NGx
2. Check the method of CI+ Key value (RS232)
1) into the main ass’y mode (RS232 : aa 00 00)
2) Check the method of CI+ key by command (RS232 :
ci 00 20)
3) Result value
i 01 OK 1d1852d21c1ed5dcx
- 14 -
CMD 1
CMD 2
Data 0
A
A
0
CMD 1
CMD 2
Data 0
C
I
1
CMD 1
CMD 2
Data 0
A
A
0
CMD 1
CMD 2
Data 0
C
I
2
CI+ key Value
- 15 -
BLOCK DIAGRAM
R
G
B
C
O
M
P
O
N
E
N
T
C
O
M
P
O
N
E
N
T
F
-
S
C
A
R
T
IF
_N
/P
_
M
S
T
A
R
DD
R3
 (
1
G
B
)
IC
1
2
0
1
NA
ND F
la
sh
HY
NI
X
(2
G
)
IC
1
0
2
U
S
B
Di
g
it
a
l a
m
p
(N
T
P
70
00
)
IC
5
0
1
CO
M
P
_
Y
/P
b/
P
S
C
1
_
C
V
B
S
/R
/G
/B
/F
B
_
IN
I2
S
DS
U
B
_
 R
/G
/B
Tun er 
( TDTJ
-S001 D)
TU37 02
L
C
D
 Pa
n
e
l
CI  Slot
( P1901 )
74LCX244
Buffer
I C1902
P
C
M
_
A
[0:
7]
TU
_
C
V
B
S
P
C
M
_
A
[0:
7]
DD
R3
 (
1
G
B
)
IC
1
2
0
2
B_
T
M
D
Q
[0
:1
6
]
MI
C
2
0
0
9
Y
M
6
US
B
 P
o
w
e
IC
4
0
2
US
B
 P
o
w
e
r
S
C
1
_
L
/R
_
IN
, E
_
A
M
_
A
U
D
IO
,A
V
_
L
/R
_
IN
C
O
M
P
_L
/R
_I
N
, P
C
_L
/R
_I
N
 
TV
/D
TV
_
V
O
U
T
A_
T
M
D
Q
[0
:1
6
]
H
e
a
d
 
P
ho
n
e
RS
-232
C
M
A
X
3
23
2C
D
R
IC
11
06
S
P
D
IF
SPD
IF
_
O
U
T
DS
UB
_H/
VSY
NC
HP
_
L
/R
O
U
T
L/
R
PI
_
T
S
_
D
A
T
A
[0
:7
]
FE
_
T
S
_
D
A
T
A
[0
:7
]
C
I_A
DD
R
[0:
7]
AUD
IO
 I
N
NE
C
_
T
X
/R
X
H
P
D
1
/2
, H
D
M
I_
C
E
C
, 5
V
_
H
D
M
I 1
/2
T
M
D
S
[0
:7
] ( 
D
a
ta
, C
lo
c
k
 (+
/-
))
US
B
_
D
M
/D
P
EE
P
R
O
M
M2
4
M
0
1-
H
R
M
N
6
(I
C
1
0
4
)
EE
P
R
O
M
CA
T
2
4
W
C
0
8
W
-T
(HDC
P
)I
C
1
0
3
I2
C
L
V
D
S
 (8
bi
or
 1
0
 bi
t)
Se
ri
a
l F
la
sh
IC
1
4
0
1
Fo
r Bo
o
t
HD
M
I 1/
2
M
P
23
05
IC
13
02
D
C
/D
C
 C
onv
.
(1
2
V
 to
 5
V
)
M
P
50
00
IC
13
05
5V
12
V
Po
w
e
r SW
(1
2
V
 O
n
/O
ff
)
N
E
C
 Mi
c
o
m
uP
D
7
8F
11
6
4
A
(I
C
1102
)
L
E
D Dr
iv
e
r
I2
C
 S
W
IC
1
0
06
/1
00
7
I2
C
I2
C
I2
C
M
S
T_
TX
/R
X
L
E
D
 C
lo
c
k
S
p
e
a
k
e
O
u
t
A
udi
o
 a
m
p
(T
P
A
3
1
2
4
D
2
)
IC
1
3
0
9
L/
R
S
p
e
a
k
e
O
u
t
C
o
n
tr
o
l
Up
/D
o
w
n
TU
_
S
IF
IF
_
A
G
C
74L
V
C
1
62
44
Bu
ff
e
r
IC
15
01
LGDT1129
FPGA
I C1503
FE
_
T
S
_
D
A
T
A
[0
]
P
K
T_
D
A
TA
[0
]
CI
_
T
S
_
D
A
T
A
[0
:7
]
R
G
B
C
O
M
P
O
N
E
N
T
C
O
M
P
O
N
E
N
T
F
-
S
C
A
R
T
IF
_N
/P
_
M
S
T
A
R
Pb
/P
Tun er 
( TDTJ
-S001 D)
TU37 02
CI  Slot
( P1901 )
74LCX244
Buffer
I C1902
TU
_
C
V
B
S
MI
C
2
0
0
9
Y
M
6
US
B
 P
o
w
e
IC
4
0
2
RS
-232
C
-T
I2
C
12
V
 
A
udi
o
 a
m
p
(T
P
A
3
1
2
4
D
2
)
IC
1
3
0
9
L/
R
TU
_
S
IF
IF
_
A
G
C
74L
V
C
1
62
44
Bu
ff
e
r
IC
15
01
LGDT1129
FPGA
I C1503
Ms
ta
r
S
7
LG
E
1
0
1
D
x
(I
C
1
0
1
)
- 16 -
300
510
560
800
400
540
900
120
122
500
804
801
805
550
530
803
A10
A2
LV
1
200
A5
EXPLODED VIEW
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These
parts are identified by       in the Schematic Diagram and EXPLODED VIEW. 
It is essential that these special safety parts should be replaced with the same components as
recommended in this manual to prevent X-RADIATION, Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
IMPORTANT SAFETY NOTICE