4) Updating is starting.
5) Uploading completed, The TV will restart automatically.
6) If your TV is turned on, check your updated version and
Tool option.(explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost all channel data. In this case, you have to
channel recover. if all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
1) Push "IN-START" key in service remote control.
2) Select “Tool Option 1” and Push “OK” key.
3) Punch in the number. (Each model has their number)
4) Completed selecting Tool option.
3.1. ADC Process
(1) ADC
G
” key at “5. ADC
Calibration”
<Caution> Using ‘power on’ button of the Adjustment remote
control, power on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
• aa 00 00 [Enter Adjust Mode]
• xb 00 40 [Component1 Input (480i)]
• ad 00 10 [Adjust 480i Comp1]
• xb 00 60 [RGB Input (1024*768)]
• ad 00 10 [Adjust 1024*768 RGB]
• aa 00 90 End Adjust mode
* Required equipment : Adjustment remote control.
3.2. Function Check
* Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (SCART1/SCART2/ CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60 hz)
5) HDMI
6) PC Audio In
* Display and Sound check is executed by Remote control.
- 10 -
No
Item CMD1 CMD2 Data0
Enter Adjust
Adjust
A
A
0
0
When transfer the ‘Mode In’,
Mode
‘Mode In’
Carry the command.
ADC adjust ADC Adjust
D
1
0
Automatically adjustment
(The use of a internal pattern)
EZ ADJUT
0. Tool Option1  
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
ADC Calibration
ADC Comp 480i
ADC Comp 1080p
ADC RGB
NG
NG
NG
Reset
Start
Module Tool option1 Tool option2 Tool option3(AU,TS) Tool option4 Tool option5
CMI
10020
8726
55337
26904
288
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
· Edge LED W/B Table in process of aging time(Only LGD
Edge LED Module except AUO, CMI, IPS Module)
CA210: CH14, Test signal : Inner pattern(80IRE)
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON ->
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color Analyzer’s prove vertically.(80° ~ 100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
• Auto adjustment Map(RS-232C)
RS-232C COMMAND
[CMD
ID DATA]
Wb
00
00
White Balance Start
Wb
00
ff
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
G
” key at “6. White
Balance”.
* After done all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory Jig model.
* Push the “IN STOP” key after completing the function
inspection. And Mechanical Power Switch must be set
“ON”.
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Assembly, EDID have to be downloaded to
Insert Process in advance.
***:Year : Controlled
****:Check sum
- 11 -
Cool 9,300
K
X=0.285(±0.002)
Y=0.293(±0.002)
<Test Signal>
Medium
8,000
K
X=0.295(±0.002)
Inner pattern
Y=0.305(±0.002)
(204 gray,80 IRE)
Warm
6,500
K
X=0.313(±0.002)
Y=0.329(±0.002)
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg 
Ja 
jd 
00
172 
192 
192
192
G Gain 
jh 
Jb
je 
00
172 
192 
192
192
B Gain 
ji 
Jc 
jf
00
192 
192 
172 
192
R Cut 
64 
64 
64 
128
G Cut 
64 
64 
64 
128
B Cut 
64 
64 
64 
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set
Aging Time
Cool
Medium
Warm
GP2R
(Min.)
X
Y
X
Y
X
Y
269
273
285
293
313
329
1
0-2
279
288
295
308
319
338
2
3-5
278
286
294
306
318
336
3
6-9
277
285
293
305
317
335
4
10-19
276
283
292
303
316
333
5
20-35
274
280
290
300
314
330
6
36-49
272
277
288
297
312
327
7
50-79
271
275
287
295
311
325
8
8-149
270
274
286
294
310
324
9
Over 150
269
273
285
293
309
323
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
4.5. Auto Download
1) After ener Service Mode by pushing “ADJ” key.
2) Enter EDID D/L menu.
3) Enter “START” by pushing “OK” key.
<Caution> Nerver connect HDMI && D-sub cable when EDID
downloaded
* Edid data and Model option download (RS232)
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Never connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2
1) HD RGB EDID data
2) HD HDMI EDID data
* Detail EDID Options are below
ⓐ Product ID
ⓑ Serial No: Controlled on production line.
ⓒ Month, Year: Controlled on production line:
ex) Week : ‘01’ -> ‘01’
Year : ‘2011’ -> ‘15’ fix
ⓓ Model Name(Hex):
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
Model Name
HEX
EDID Table
DDC Function
FHD Model
0001
01 00
Analog/Digital
- 12 -
MODEL
MODEL NAME(HEX)
all
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
INPUT
MODEL NAME(HEX)
HDMI1 65030C001000
HDMI2 65030C002000
HDMI3 65030C003000
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
00
ff
ff
ff
ff
ff
ff
00
1e
6d
a
b
10
c
01
03
68
10
09
78
0a
ee
91
a3
54
4c
99
26
20
0f
50
54
a1
08
00
81
80
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
02
3a
80
18
71
38
2d
40
58
2c
40
45
00
a0
5a
00
00
00
1e
01
1d
00
72
51
d0
1e
20
50
6e
28
55
00
a0
5a
00
00
00
1e
00
00
00
fd
00
3a
60
3e
1e
53
10
00
0a
20
20
20
20
20
20
d
70
d
00
e
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
00
ff
ff
ff
ff
ff
ff
00
1e
6d
a
b
10
c
01
03
80
10
09
78
0a
ee
91
a3
54
4c
99
26
20
0f
50
54
a1
08
00
71
4f
81
80
01
01
01
01
01
01
30
01
01
01
01
01
01
02
3a
80
18
71
38
2d
40
58
2c
40
45
00
a0
5a
00
00
00
1e
1b
21
50
a0
51
00
1e
30
50
48
88
35
00
a0
5a
00
00
00
1c
00
00
00
fd
00
3a
60
3e
1e
53
10
00
0a
20
20
20
20
20
20
d
70
d
01
e
80
02
03
20
f1
4e
10
1f
84
13
05
14
03
02
12
20
21
90
22
15
01
26
15
07
50
09
57
07
f
A0
01
1d
80
18
71
1c
16
20
58
2c
25
00
a0
5a
00
00
B0
00
9e
01
1d
00
72
51
d0
1e
20
6e
28
55
00
a0
5a
C0
00
00
00
1e
02
3a
80
18
71
38
2d
40
58
2c
45
00
D0
a0
5a
00
00
00
1e
01
1d
00
bc
52
d0
1e
20
b8
28
E0
55
40
a0
5a
00
00
00
1e
8c
0a
d0
8a
20
e0
2d
10
F0
10
3e
96
00
a0
5a
00
00
00
18
00
00
00
00
00
e
NO
Item
CMD1 CMD2 Data0
Enter
Download
A
A
0
0
When transfer the ‘Mode In’,
download Mode
‘Mode In’
Carry the command.
EDID data and
Download
A
E
00 10 Automatically Download
Model option
(The use of a internal pattern)
download
EZ ADJUT
0. Tool Option1  
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
EDID D/L
HDMI1
HDMI2
HDMI3
RGB
NG
NG
NG
NG
Reset
Start
EDID D/L
Reset
Start
HDMI1
HDMI2
HDMI3
RGB
OK
OK
OK
OK
- 13 -
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Product/Service
info.(menu key -> red key -> select product/Service info)
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, Sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the ‘instart’ key of ADJ remote control.
2) Go to the menu ‘6.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 32LV2510-TB) or Serial
number like photo.
4) Check the model name Instart menu -> Factory name
displayed (ex 32LV2510-TB)
5) Check the Product/Service info.(Menu key -> Red key ->
Select product/Service info)
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex)
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Page of 61
Display

Click on the first or last page to see other 22LV2510 / 22LV2530 (CHASSIS:LB01S) service manuals if exist.