- 13 -
5. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number by use RS-232.
▪  Must  check  the  serial  number  at  the  Diagnostics  of  SET  UP 
menu. (Refer to below).
5.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
5.2. Comand Set
* Description
FOS Default write : <7mode data> write
Vtotal,  V_Frequency,  Sync_Polarity,  Htotal,  Hstart,  Vstart,  0, 
Phase
Data write :  Model Name and Serial Number write in EEPROM,.
5.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced in 
production  line,  because  serial  number  D/L  is  mandatory  by 
D-book 4.0.
* Manual Download(Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, sometimes 
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need 
Manual download.
1) Press the "Instart" key of Adjustment remote control.
2) Go to the menu "6.Model Number D/L" like below photo.
3)  Input the Factory model name or Serial number like photo.
4)  Check the model name Instart menu. → Factory name displayed. 
(ex 42LD450-ZA)
5)  Check  the  Diagnostics.(DTV  country  only)  →  Buyer  model 
displayed.(ex 42LD450)
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
- 14 -
6. CI+ Key Download method
6.1. Download Procedure
(1) Press "Power on" key of a service R/C.
     (Baud rate : 115200 bps)
(2) Connect RS232-C Signal Cable.
(3) Write CI+ Key through RS-232-C.
(4)  Check whether the key was downloaded or not at ‘In Start’ 
menu. (Refer to below).
=> Check the Download to CI+ Key value in LGset. 
1. Check the method of CI+ Key value
a. Check the method on Instart menu
b. Check the method of RS232C Command 
1) Into the main ass’y mode (RS232 : aa 00 00)
2) Check the key download for transmitted command 
    (RS232 : ci 00 10)
3) Result value
- Normally status for download : OKx
- Abnormally status for download : NGx
2. Check the method of CI+ key value (RS232)
1) Into the main ass’y mode (RS232 : aa 00 00)
2) Check the mothed of CI+ key by command
    (RS232 : ci 00 20)
3) result value
i 01 OK 1d1852d21c1ed5dcx
CMD 1
CMD 2
Data 0
A
A
0
0
CMD 1
CMD 2
Data 0
C
I
1
0
CMD 1
CMD 2
Data 0
A
A
0
0
CMD 1
CMD 2
Data 0
C
I
2
0
 
CI
+ Key Value
 
- 16 -
A2
A2
1
A9
A3
1
A1
0
* Set + Stand
* Stand Base   + Body
90
0
200
400
540
521
820
91
0
120
30
0
51
0
50
1
50
0
LV
1
EXPLODED VIEW
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These 
parts are identified by       in the Schematic Diagram and EXPLODED VIEW. 
It  is  essential  that  these  special  safety  parts  should  be  replaced  with  the  same  components  as 
recommended in this manual to prevent X-RADIATION, Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
IMPORTANT SAFETY NOTICE