LG 22LE5300 (CHASSIS:LL01A) Service Manual ▷ View online
4.1.1. Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON -> Enter
the mode of White-Balance, the pattern will come out
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON -> Enter
the mode of White-Balance, the pattern will come out
4.1.2. Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
Module and Color Analyzer’s Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
4.1.3. Auto adjustment Map (RS-232C)
**Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of
Module)
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of
Module)
4.2. Manual W/B process using adj. R/C
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
• Enter White Balance by pushing “
G
” key at “6. White
Balance”
* After done all adjustments, Press “In-start” button and compare
Tool option and Area option
value with its BOM, if it is correctly same then unplug the AC
cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
* Push The “IN STOP KEY” after completing the function
inspection.
- 13 -
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
255
G Gain
jh
Jb
je
00
172
192
192
255
B Gain
ji
Jc
jf
00
192
192
172
255
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
4.3. DDC EDID Write (RGB 128Byte )
· Connect D-sub Signal Cable to D-Sub Jack.
· Write EDID DATA to EEPROM (24C02) by using DDC2B
· Write EDID DATA to EEPROM (24C02) by using DDC2B
protocol.
· Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.4 DDC EDID Write (HDMI 256Byte)
· Connect HDMI Signal Cable to HDMI Jack.
· Write EDID DATA to EEPROM(24C02) by using DDC2B
· Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
· Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.5 EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
- Auto Download
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Nerver connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing.
4) Download HDMI1, HDMI2 separately because each data is
3) Use the proper cables below for EDID Writing.
4) Download HDMI1, HDMI2 separately because each data is
different.
- 14 -
EZ ADJUT
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
EDID D/L
HDMI1
HDMI2
HDMI3
RGB
NG
NG
NG
NG
Reset
Start
EDID D/L
HDMI1
HDMI2
HDMI3
RGB
OK
OK
OK
OK
Reset
Start
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
(1) FHD RGB EDID Data (CS : 1D)
(2) FHD HDMI EDID Data (CS : D739)
(3) FHD HDM2 EDID Data (CS : D739)
(4) HD RGB EDID Data (CS : 93)
(5) HD HDMI1 EDID Data (CS : 7AD5)
(6) HD HDMI2 EDID Data (CS : 7AD5)
(7) HD HDMI3 EDID Data (CS : 7AB5)
(8) ASCII Code
- 15 -
4.6. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
· V-COM default value is different from module.
1) 32LD460 : 417
2) 37LD460 : 432
3) 42LD460 : 433
4) 47LD460 : 447
5) 37LE5300 : 378
5) 42LE5300 : 450
5) 47LE5300 : 460
5) 55LE5300 : 444
2) 37LD460 : 432
3) 42LD460 : 433
4) 47LD460 : 447
5) 37LE5300 : 378
5) 42LE5300 : 450
5) 47LE5300 : 460
5) 55LE5300 : 444
4.7. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
- 16 -
Row Li ne
Column Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
Driv
e
IC
So urce D r i v e I C
Circuit Block
Ti m i n g
Co nt r o ll e r
Co nt r o ll e r
Po w e r
Blo ck
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
Con t rol si gnal
In
te
te
r
fa
c
e
TFT
Po w e r I n p u t
Power Input
Da t a I n p u t
Da t a I n p u t
V
COM
Liquid
Crys tal
Crys tal
V
COM
Click on the first or last page to see other 22LE5300 (CHASSIS:LL01A) service manuals if exist.