DOWNLOAD LG GR-L247ER Service Manual ↓ Size: 5.74 MB | Pages: 127 in PDF or view online for FREE

Model
GR-L247ER
Pages
127
Size
5.74 MB
Type
PDF
Document
Service Manual
Brand
Device
Refrigerator
File
gr-l247er.zip
Date

LG GR-L247ER Service Manual ▷ View online

2-2. Control of Variable Speed Fan in the Refrigerator Compartment
1. Fan motor in the freezer compartment shall change from standard to high speed rpm in order to increase cooling speed
and load corresponding speed.
2. High speed rpm is only used for the initial power  application and load corresponding  operation. But  standard rpm  is
used  in the  general working conditions.
3. Fan motor in the freezer compartment operates normally when freezer, refrigerator, or home  bar door opens and fan
motor in the freezer compartment operates (the speed changes from high to standard rpm if fan motor operates at high
speed rpm). But fan motor in the freezer compartment stops when refrigerator or home bar door is open and refrigerator
compartment door is closed.
2-3. Door Opening Alarm
1. Buzzer warns when freezer, refrigerator, or home bar door is kept open for more than 1 minute.
2. Buzzer warns 3 times at 0.5 second interval and then 3 times at 0.5 second on and off in every 30  seconds if door is kept
open for more than 1 minute.
3. Warning is released  when freezer, refrigerator, or home  bar door is closed during door opening alarm.
2-4 Button Selection Buzzer Sound
1. “Bell” sounds when button on the front display is pressed.
2-5. Forced Start, Forced Defrost Buzzer Warning
1. When test button in the main PWB is pressed, “beep” sounds.
2. When forced start is selected, warning sounds three times for 0.2 second on and 1.8 seconds off.
3. When forced defrost is selected, warning sounds three times in the following cycle: 0.2 second on and 0.2 second off, 0.2
second on and 0.2 second off, and 0.2 second on and 1.0 second off.
2-6. Functions of Defrost
1. Defrost starts whenever the compressor operation time accumulates to seven to seven and a half hours.
2. Defrost starts whenever the compressor operation time accumulates to four to four and a half hours if power is initially
applied (or reapplied after power cut).
3. Defrost completes  when the temperature of defrost  sensor reaches at 5 
°
C. Faulty defrost is indicated if the defrost
sensor does not reach at 5 
°
C after 2 hours of defrosting.
4. Defrost does not work when defrost sensor is out of order (wire cut or short-circuit).
MICOM FUNCTION
- 26 -
Closed
Open
Closed
Open
3Times
3Times
3Times
3Times
Closed
Within one minute
one minute
30
 Seconds
30
 Seconds
30
 Seconds
Freezer, 
Refrigerator,
or 
Home Bar Door
Buzzer
2-7. Electric Equipment Sequential Operation
Electric equipment such as compressor, defrost heater, cooling fan, step motor damper, etc. operates in the following
sequence when power is initially applied and test is completed in order to reduce  noise and parts damage.
MICOM FUNCTION
- 27 -
Function
Operation Sequence
Remarks
When
po
w
e
r
is
initially
applied
TEST
MODE
Defrost sensor
temperature is
above 10 
°
(purchased or
house-moving)
If there is any error in
functions, initial
starting does not
work.
If switch is pressed
one more or defrost
sensor temperature
is above +5 
°
C, it
returns to test mode
and restarts.
(compressor shall
operate after 7
minutes)
Defrost sensor
temperature is
below 10 
°
C
(power cut or
service)
Test Mode 1
(Forced Start)
Test Mode 2
(Check Freezer
fan )
Test Mode 3
(Forced defrost)
POWER
ON
COMP
ON
WATER
TANK
HEATER
ON
FAN 1400
(High Speed
Operation)
ON
FAN 1400
(High Speed
Operation)
ON
FAN 1400
(High Speed
Operation)
OFF
WATER
TANK
HEATER
OFF
FAN 1170
(Standard
Operation)
ON
FAN 1170
(Standard
Operation)
OFF
STEP
MOTOR
DAMPER
ON
STEP
MOTOR
DAMPER
ON
STEP
MOTOR
DAMPER
OPEN
STEP
MOTOR
DAMPER
CLOSE
HOME
BAR
HEATER
ON
POWER
ON
DEFROST
HEATER
ON
HOME
BAR
HEATER
OFF
HOME
BAR
HEATER
ON
TEST
S/W
(Press
Once)
COMP
ON
TEST
S/W
(Press
Twice)
COMP
OFF
0.5
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.5
sec.
8
sec.
0.3
sec.
5
sec.
DEFROST
HEATER
OFF
DEFROST
HEATER
ON
5
sec.
0.3
sec.
COMP
ON
FAN 1170
(Standard 
Operation)
ON
STEP
MOTOR
DAMPER
ON
27
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
0.3
sec.
OTHER
LOADS
OFF
TEST
S/W
(Press
Three
Times)
0.3
sec.
0.3
sec.
2-8. Function of Trouble Diagnosis
1. Function of trouble diagnosis is to make the repair  service easy when the refrigerator is out of order during service.
2. The function control button does not work but the recognition sound is heard when the refrigerator is out of order.
3. It returns to normal conditions when trouble code led is off. (reset)
4. Trouble code is indicated by the freezing temperature indicator led in the refrigerator display. All leds except trouble code
are off.
MICOM FUNCTION
- 28 -
FRZ
TEMP
REF
TEMP
SELECT
Max
Min
1
3
5
F1
F2
F3
F4
TROUBLE
CODE INDEX
A
B
C
D
Trouble Code Indicator
Operation conditions during Trouble
No.
Trouble
Troubles
Freezer
Defrost
Step motor
F4      F3     F2     F1
Compressor
Fan
Heater
Damper
1
Abnormal Freezer 
l
l l 
Freezer sensor short 
15 min. on/ Standard
ˇ 
ˇ 
sensor. 
15 min. off
RPM
Abnormal Refrigerator 
2
sensor 1 (R1)
l l  l
Refrigerator sensor 1 short circuit
ˇ 
Standard
ˇ 
Note 2)
(Upper part in the
RPM
refrigerator compartment)
Abnormal Refrigerator
3
sensor 2 (lower part 
Note 1)
Refrigerator sensor 2  short circuit
ˇ 
Standard
ˇ 
ˇ 
in the refrigerator 
RPM
compartment)
4
Abnormal Defrost 
l  l l
Defrost sensor short circuit
ˇ 
Standard
No 
ˇ 
sensor 
RPM
defrosting
Failed defrosting
Defrost Heater, Temperature Fuse 
5
   
short circuit. 
ˇ 
Standard
ˇ 
ˇ 
Unplugged Connector
RPM
(Indicated 4 hour later after trouble)
Abnormal Open Air 
Open air temperature detecting sensor 
6
Temperature 
Note 1)
short circuit
ˇ 
ˇ 
ˇ 
Detecting sensor
7
Abnormal
Note 1)
Defrost sensor short circuit.
ˇ 
ˇ 
ˇ 
ˇ 
ice making sensor
Abnormal
Faulty Ice Maker Unit Motor or
8
ice maker unit
Note 1)
Hall IC, L/Wire short circuit.
ˇ 
Standard
ˇ 
ˇ 
Faulty motor driving circuit.
RPM
   
: On
: Off
ˇ  
: Normal
Note 1) When open  air temperature detecting  sensor, refrigerator sensor 2, ice maker unit, ice  making sensor are
abnormal, it is not indicated in the trouble code. But it  is   indicated while checking LED (press freezer and
refrigerator temperature control buttons  for more than 1 second  at the same time).
Room Temperature 
Normal :
LED On.
Detection Sensor
Abnormal : 
LED Off.
Refrigerator Sensor 2 
Normal :
LED On.
(lower shelf)
Abnormal : 
LED Off.
Home Bar Sensor
Normal :
LED On.
Abnormal : 
LED Off.
Ice Maker Unit
Normal :
LED On.
Abnormal : 
LED Off.
Note 2) When refrigerator sensor is abnormal, it opens for 10 minutes and closes for 15 minutes.
2-9. Test Function
1. Test function is to check the function of PWB and products and to find defective parts when the refrigerator is out of order.
2. Test button is on the main PWB of the refrigerator. Test mode completes after 2 hours in maximum and returns to normal
conditions.
3. Function control button does not work but button recognition sound is heard during the test mode.
4. When test mode is completed, unplug and replug the power cord to return to the normal conditions.
5. When sensor is abnormal in the test mode, test mode is released and trouble code is indicated.
6. Test mode does  not work even test button is pressed when trouble code indicator is on.
MICOM FUNCTION
- 29 -
Mode
Operation
Contents
Remarks
Test 1
Test 2
Test 3
Normal
Press test button once
Press test button once in
Test Mode 1
Press test button once in
Test Mode 2
Press test button onec in
test mode 3
1. Continuous compressor operation
2. Continuous freezer fan (high rpm) operation
3. Defrost heater off.
4. All display LEDs are on.
5. Electronic stepping motor damper open
(baffle is open).
1. Compressor off.
2. Freezer fan (high rpm) off.
3. Freezer fan (standard rpm) on.
4. Defrost heater off.
5. “Medium Weak” led in freezer and
refrigerator temperature indicators are on.
6. Step motor damper open condition 
(baffle is open)
1. Compressor is off.
2. Freezer fan off.
3. Defrost heater on.
4. “Medium” leds in freezer and refrigerator
temperature indicators are on.
5. Step motor damper closed condition 
(baffle is open)
Return to initial conditions
Forced start
Check fan in the freezer 
compartment 
• Return to normal
conditions when defrost
sensor is above 5 
°
C.
• Forced defrost.
Compressor starts after
seven minutes.
A
A
B
B
C
C
D
D
The rest of 
LEDs are all on
Page of 127
Display

Click on the first or last page to see other GR-L247ER service manuals if exist.