7-2 PCB CIRCUIT OPERATION
7-2-1 POWER SOURCE CIRCUIT
TRANS 2nd part A is composed of the RELAY-operating POWER(12Vdc) and power (5Vdc) supplying POWER to MICON
and IC.
TRANS 2nd part B is composed of the CIRCUIT supplying POWER(12Vdc) to DISPENSER PUMP MOTOR.
Voltage of each part is as follows.
VA1 is a part preventing from over-voltage and noise.
7-2-2 OSCILLATION CIRCUIT
CIRCUIT for occuring CLOCK which motivates the internal local element of IC1 to transmit and receive an information and
BASIC TIME for calculating time. Use a proper form for OSC 1. Because in case that SPEC is changed, the calculated time
in IC1 is changed or IC 1 isn't able to operate.
- 23 -
POWER
3
1
VA1
SVC471
D14A
CM1
223
D1~D4
1N4004*4
TRANS
D6~D9
1N4004*4
CE1
2200µF
/35V
CM2
223
CC1
223
A
CON1
B
+
CE6
1000µF
/35V
+
CE7
470µF
/25V
+
CE2
1000µF
/25V
+
CC2
223
CE3
470µF
/25V
CE4
220µF
/16V
CE5
220µF
/16V
CC3
223
10mH
IN404
+
+
+
IC2
R3
10K
IC3
L1
42 VDD
Varef
IC1
(MICOM)
Vss(Vass)
TEST
22
21
17
D5
7812
IC4
7812
7805
PART A
PART
both ends of VA1
both ends of CM1
both ends of CM2
both ends of CE2
both ends of CC2
VOLTAGE
220 Vac
14 Vac
17 Vdc
12 Vdc
5 Vdc
PART B
PART
both ends of 2nd part
both ends of CE6
both ends of CE7
VOLTAGE
13 Vdc
15 Vdc
12 Vdc
OSC1
CST4.OOMGW
R9
19
20
1M
XIN
XOUT
IC1
(MICOM)
- 32 -
7-3. RESISTANCE SPECFICATION OF SENSOR
• The resistance of SENSOR has ±5% common difference.
• Measure the resistance of SENSOR after leaving it over 5 mintues in measureing temperature.
This postponing is necessary because of perceiving speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE SENSOR
RESISTANCE OF FREEZER
RESISTANCE OF REFRIGERATOR
(SUPER FROST) SENSOR
(DEFROST) SENSOR
- 20 ˚C
22.3 K
77 K
- 15 ˚C
16.9 K
60 K
- 10 ˚C
13.0 K
47.3 K
- 5 ˚C
10.1 K
38.4 K
0 ˚C
7.8 K
30 K
+ 5 ˚C
6.2 K
24.1 K
+ 10 ˚C
4.9 K
19.5 K
+ 15 ˚C
3.9 K
15.9 K
+ 20 ˚C
3.1 K
13 K
+ 25 ˚C
2.5 K
11 K
+ 30 ˚C
2.0 K
8.9 K
+ 40 ˚C
1.4 K
6.2 K
+ 50 ˚C
0.8 K
4.3 K
7-2-3 RESET CIRCUIT
All the internal parts of MICOM(IC 1) return to the early condition when the early power ON or apply power again in MICOM
after temporary power failure. As a result, all the functions operate according to the early condition. At the early period of
power ON the "LOW" voltage is applied in the RESET terminal of MICOM for the fixed time. The RESET terminal is 5V
during the general operation.
- 24 -
18
IC7
CC5
223
CC6
223
R10
4.7K
RESET
ICI
(MICOM)
KIA7045P
7-2-4 LOAD & BUZZER OPERATION CIRCUIT & DOOR OPEN DETECTION CIRCUIT
1. LOAD OPERATION CHECK
* When the DOOR of freezer room or refrigerator room is opened, FAN MOTOR i s stoped immediately, then when the door
is closed, the FAN MOTOR is operated after 20 sec.
(FAN MOTOR 20 sec delay)
- 25 -
D13
IN4148
RY-4
G5N-1
RY-5
G5N-1
R49
R4
BUZZER
470
12K/5W
D14
IN4148
1K
R5
13
14
4
15
2
6
8
8
4
3
R7
100
CC4
223
R6
10K
3
D13
IN4148
RY-3
G5N-1
12
5
1
2
3
D11
IN4148
RY-2
G5N-1
11
6
4
D10
IN4004
RY-1
G2R-1A(10A)
10
7
9
IC5
KID65003AP
5
F.I.R LAMP
PTC START
POWER
DOOR S/W–R
LAMP–R
LAMP–F
D15
IN4148
COOLING-FAN
OLP
COMP
MODEL
OPTION
M
DOOR S/W-F
D17
IN4007
CON 3
D16
1
2
56K/2W
DAMPER
MOTOR
FUSE–M
CON 2
F–FAN
2400 rpm
2800 rpm
DEF–HEATER
R8
IC6
TLP621(BL)
IN4007
7
9
5
3
1
5
3
1
M
M
P70
P72
(PDO/PWM)
P77
P76
P75
P74
P73
IC1
(MICOM)
RUNNING CAPACITOR
STARTING CAPACITOR
KIND OF LOAD
COMP,
FAN MOTOR
DEFROSTING HEATER
ELEC. DAMPER
COMP COOLING FAN
2800rpm 2400rpm
MEASURING POINT(IC3)
NO.10
NO.11
NO.12
NO.14
NO.13
ON
below 1V
STATE
OFF
12V