8) SELF-TEST
(1) Function to make service easy in case of occuring a trouble in the product.
(2) When occurring a trouble, if the button is pushed, but the function could not operate.
(3) If a toruble release during the representation of trouble, a refrigerator performs the normal function(RESET).
(4) To represent a ERROR CODE, it use FREEZE TEMP LEDs on TOP COVER. If ERROR occurs, the other LEDs except
ERROR CODE LEDs are all off.
ERROR CODE LEDs
OPERATION IN TROUBLE'S OCCURRING
NO.
ITEMS
F1    F2    F3    F4
DESCRIPTION
COMP
FAN
DEFROST HEATER
1
FREEZER
FREEZER SENSOR open 
SENSOR abnormal
or short.
O
O
2
DEFROST
DEFROST SENSOR open 
SENSOR abnormal
or short.
O
O
No defrosting
3
DEFROSTING
DEFROST HEATER, 
FUNCTION
TEMP. FUSE open or
is abnormal
disconnection (Displayed 
after at least 4 hours 
O
O
O
from the trouble's
occurring.)
4
RT-SENSOR NOTE 
1)
Room Temperature
abnormal
SENSOR open or short 
O
O
O
- 19 -
VACATION
FREEZE TEMP
QUICK FREEZE
F1
ERROR CODE LEDs
F2
F3
F4
15 minutes On/
15 minutes Off
NOTE 1) If one second pass after pressing the QUICK FREEZE and FREEZE TEMP buttons togather in normal
operation, operates as follow.  
If normal, LEDs on the TOP COVER is all on. 
If abnormal, LEDs are all on except VACATION LED.
RT-SENSOR
:ON
O : OPERATE NORMAL
:OFF
9) FUNCTION TEST
(1) Function to check the testing function of PCB and refrigerator and to find where the trouble.
(2) The test switch is on the MAIN PCB of refrigerator.
TEST FUNCTION is released and RESET after MAX. 2hours regardless of TEST MODE.
(3) If the buttons on TOP COVER is pushed during TEST MODE, Function is not operated and only BUZZER ring with
"DING~ DONG~"
(4) After the end of TEST MODE, pull out the power cord and plug it in again(RESET).
(5) If a ERROR occurs during the TEST MODE, TEST FUNCTION is released and DISPLAY LEDs represent ERROR
CODE.
(6) If the TEST swithch is pushed during ERROR CODE, TEST FUNCTION is not operated.
MODE
OPERATION
CONTENTS
REMARKS
TEST 1
Press TEST button 
1. COMP OPERATES SUCCESSIVELY.
once.
2. FAN OPERATES SUCCESSIVELY.
3. DEFROSTING HEATER OFF
4. ALL DISPLAY LEDS ON.
TEST 2
Press TEST button
1. COMP OFF.
If DEFROST HEATER 
once in the state of 
2. FAN OFF.
is over 7
°
C, it returns 
TEST MODE 1.
3. DEFROST HEATER ON.
to the NORMAL STATE.
4. ALL THE DISPLAY LEDS OFF EXCEPT 
QUICK FREEZE AND VACATION LEDS.
NORMAL
Press TEST button 
Return to the  initial condition. 
Comp starts 
STATE
once in the state of  
(RESET)
after 7 minutes.
TEST MODE 2.
- 20 -
• LED Check Function : Press the QUICK FREEZE and FREEZE TEMP buttons at the same time. After 1 sec., all the
LEDs of the DISPLAY are ON simultaneously. If release the BUTTON, return to the previous
condition.
NOTE : This is a basic model. The shape of refrigerator is subject to change.
PARTS IDENTIFICATION
- 5 -
Rotatable 
Door Basket
(3 or 5)
Utility Corner
(movable)
 
Bottle Holder
2
L
 Bottle 
Door Basket
Leveling Screw
Egg Tray(1 or 2)
Freezer Temperature
Control
Removable
Glass Shelf(2 or 3)
Lamp
Multi-air Flow Duct
Fresh Meat Keeper
(Optional)
Refrigerator
Temperature Control
Vegetable Drawer
Used to keep fruits
and vegetables, etc.
fresh and crisp.
Ice Cube Tray
Freezer
 Compartment
Removable
 Plinth
NOTCH
TEMP(˚C)
ROOM
Min
Min/
Mid
Mid
Mid/
Max
Max
-15
-16.5
-18
-19.5 
FREEZER
VACATION
FREEZE TEMP
QUICK FREEZE
-22
This description is made for GR-349, 389SQ. Please refer to overall PCB circuits for other models.
1 FUNCTION EXPOSITION
1) FUNCTION
(1) The refrigerator starts from optimum condition when electric power is first on. But the operation condition changes "Mid"
"Mid/Max" 
"Max" 
"Min" 
"Min/Mid" 
"Mid" whenever pressing the FREEZE TEMP button.
(2) It returns to "Mid" conditions if power off and on again.
MICOM FUNCTION & PCB CIRCUIT EXPLANATION
- 17 -
2) QUICK FREEZER
(1) Function to raise the freezing speed by operating the COMP successively. As pressing the QUICK FREEZE button, the
QUICK FREEZE LED is displayed. Then after 3 hours' successive operation of COMP, the QUICK FREEZING function
will be released.
(2) Defrosting During the QUICK FREEZING operates as follow.
When the QUICK FREEZING time is below 90 minutes, defrost and then operate the QUICK FREEZING for the
remaining time. When the QUICK FREEZING time is over 90 minutes, defrost and then operate the QUICK FREEZING
for 2 hours
(3) If QUICK FREEZE button is pressed during defrosting, the QUICK FREEZE LED is lit up. But the QUICK FREEZING
operates for 3 hours after 7 minutes from the end of defrosting.
(4) If VACATION button is pressed during the QUICK FREEZING, the QUICK FREEZING LED function is released.
(5) If power off during the QUICK FREEZING and power on again, the QUICK FREEZING function is released.
3) VACATION FUNCTION
(1) Function for Energy Saving. As pressing the VACATION button, the VACATION LED is displayed and this function is
operated.
(2) Freezer Compartment is not kept by compressor at the notch displayed but at -13
°
C
±
differential.
(3) Defrosting and Fan control is same as normal operation.
(4) If QUICK FREEZE button is pressed during the VACATION FUNCTION, VACATION FUNCTION is released.
(5) If power off during the VACATION FUNCTION and power on again, the VACATION FUNCTION is released.
Page of 44