LG MS-2342W Service Manual ▷ View online

8-2
PRINTED CIRCUIT BOARD
Jan., 2003
P/NO:3828W5S2952
1-1
This microwave oven is designed for household use only.
It is not recommended for commercial purposes.
ITEM
MODEL
Power Requirement
Power Output
Microwave Frequency
Magnetron
Timer
Outside Dimensions
Cavity Dimensions
Net Weight
Shipping weight
Control Complement
Nameplate Location
Accessories
DESCRIPTION
MS-2342W
230 Volts AC 50 Hz 
1,200 Watts 
Single phase, 3 wire grounded
800 Watts full microwave power (IEC 60705)
2,450 MHz
2M214 - 39F
0 ~ 99 min. 50 sec.
485 (W) x 280 (H) x 400 (D) mm
332 (W) x 200 (H) x 331 (D) mm
12.5 kg (approx.)
14 kg (approx.)
Microwave Power for Variable Cooking
Power level
Max                                   Full power throughout the cooking time
Med.-High
approx. 80% of Full power 
Medium                            approx. 60% of Full power 
Defrost                              approx. 40% of Full power 
Low/Warm 
approx. 20% of Full power 
Owner's manual 
Glass turntable
Rotating Ring
Back Side
SPECIFICATIONS
• DO NOT operate on a 2-wire extension cord during
repair and use.
• NEVER TOUCH any oven components or wiring during
operation.
• BEFORE TOUCHING any parts of the oven, always
remove the power plug from the outlet.
• For about 30 seconds after the oven stops, an electric
charge remains in the high voltage capacitor. When
replacing or checking, you must discharge the high
voltage capacitor by shorting across the two terminals
with an insulated screwdriver.
• Remove your watches whenever working close to or
replacing the Magnetron.
• DO NOT touch any parts of the control panel circuit. A
resulting static electric discharge may damage this
P.C.B.
• NEVER operate the oven with no load.
• NEVER injure the door seal and front plate of the oven
cavity.
• NEVER put iron tools on the magnetron.
• NEVER put anything into the latch hole and the
interlock switches area.
• Proper operation of the microwave oven requires that
the magnetron be assembled to the waveguide and
cavity. Never operate the magnetron unless it is
properly installed.
• Be sure that the magnetron gasket is properly
installed around the dome of the tube whenever
installing the magnetron.
2-1
CAUTIONS
Unlike other appliances, the microwave oven is
high-voltage and high-current equipment.
Though it is free from danger in ordinary use,
extreme care should be taken during repair.
THE OVEN IS TO BE SERVICED ONLY
BY PROPERLY QUALIFIED SERVICE
PERSONNEL.
MICROWAVE RADIATION
Personnel should not be exposed to the
microwave energy which may radiate from the
magnetron or other microwave generating
device if it is improperly used or connection.
All input and output microwave connections,
waveguide, flange and gasket must be secure
never operate the device without a microwave
energy absorbing load attached.
Never look into an open waveguide or antenna
while the device is energized.
Gasket
ANTENNA
COOLING FIN
MAGNETRON
CHASSIS GROUND
FILAMENT
TERMINALS
MAGNETRON