5-15
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while          
desired program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operation but little heat  is produced in oven load.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1.Setting time does
not count down
when touching
START pad.
2. Fan motor or
oven lamp
do not turn
on.
No continuity.
continuity.
No continuity.
Continuity.
Check the con-
nection between
connector and
P.C.B assembly.
Defective
secondary switch.
Replace
secondary switch.
Defective P.C.B
assembly.
Replace P.C.B
assembly.
Check continuity
of secondary
switch (with
door closed).
Check fan motor.
Check oven lamp.
Abnormal.
Abnormal.
Normal.
Defective fan
motor.
Defective fan
motor.
Replace fan
motor.
Replace fan
motor.
Loose connection.
Connection then
tightly.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low.
Lower than 90% of
rating voltage.
Normal.
Normal.
Abnormal.
Abnormal.
Measure the
output power.
Disconnect the
wire leads from
relay 2 and check
on and off time
with multitester.
Defective P.C.B
assembly.
Replace  P.C.B
assembly.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Defective
magnetron.
Replace
magnetron.
NOTE: Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5
o
C temperature rise is normal condition.
5-16
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective P.C.B
assembly
Replace P.C.B
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the
unit)
Abnormal
normal
Defective high
voltage
transformer.
Replace high
voltage
transformer .
Check H.V.
transformer.
normal
normal
Abnormal
Defective high
voltage Diode.
Replace high
voltage Diode.
Check H.V.
diode.
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check H.V.
capacitor.
Abnormal
normal
Defective
magnetron.
Replace
magnetron .
Check
Magnetron.
Abnormal
Defective
Protector Diode.
Replace 
Protector Diode .
Check
Protector Diode.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run
(Display operates properly)
5-17
(TROUBLE 6) Oven does not cook properly when programmed for the set power level 
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.  
LATCH BOARD PARTS
INTERIOR PARTS
BASE PLATE PARTS
OVEN CAVITY PARTS
DOOR PARTS
CONTROL PANEL PARTS
6-1
EXPLODED VIEW
INTRODUCTION
Page of 37
Display

Click on the first or last page to see other MS-2042G (serv.man2) service manuals if exist.