LG MS-196G Service Manual ▷ View online

6-5
43501A
43500A
466001
WSZ084
466003
466001
44510A
LATCH BOARD PARTS
6-6
WSZ002
WSZ002
WTT028
WSZ002
WTT028
WSZ062
WSZ002
WTT037
50CZZH
56324A
55262A
54810C
55900A
56549F
56411A
56930V
568771
54974S
56912B
34930W
50FZZA
56201A
WSZ002
56851C
INTERIOR PARTS
6-7 
WTT028
56170D
63302A
63303A
WTT021
WSZ002
65006B
948503
BASE PLATE PARTS
NECESSARY TOOLS
Tools normally used for TV servicing are sufficient.
Standard tools are listed below.
• Diagonal pliers
• Long nose pliers
• Phillips screwdriver
• Flat blade screwdriver
• Wrench (size 5mm)
• Nutdriver (size 5mm)
• Adjustable wrench
• Soldering iron
• Solder
• Vinyl insulation tape
• Polishing cloth
CAUTIONS
• Be sure to check microwave leakage prior to
servicing the oven if the oven is operative prior to
servicing.
• The service personnel should inform the
manufacture importer, or assembler of any certified
oven unit found to have a microwave emission
level in excess of 5 mW/cm
2
and should repair any
unit found to have excessive emission levels at no cost
to the owner and should ascertain the cause of the
excessive leakage. The service personnel should
instruct the owner not to use the unit until the oven has
been brought into compliance.
• If the oven operates with the door open, the service
personnel should:
- Tell the user not to operate the oven.
- Contact the manufacturer.
• The service personnel should check all surface and
vent openings for microwave leakage.
• Check for microwave leakage after every servicing. The
power density of the microwave radiation leakage
emitted by the microwave oven should not exceed 
5 mW/cm
2
. Always start measuring of an unknown field
to assure safety for operating personnel from radiation
leakage.
NECESSARY MEASURING INSTRUMENTS
• TESTER(VOLTS-DC, AC., Ohmmeter)
• Microwave survey meter
- Holaday HI-1500
HI-1501
- Narda     8100
8200
• Inch scale
• 600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5 cm(3
1
/2
in.)
• Cylindrical and made of borosilicate glass vessel.
max. thickness: 3 mm
outside diameter: approx. 190mm
height: approx. 90mm
• Glass thermometer: 100°C or 212°F (1 deg scale)
MEASURING MICROWAVE ENERGY
LEAKAGE
• Pour 275±15 cc of 20±5°C(68±9°F) water in a beaker
which is graduated to 600 cc, and place the beaker
on the center of the turntable.
• Set the energy leakage monitor to 2,450 MHz and
use it following the manufacturer's recommended
test procedure to assure correct result.
• When measuring the leakage, always use the 2-inch
(5 cm) spacer supplied with the probe.
• Operate the oven at its maximum output.
• Measure the microwave radiation using and
electromagnetic radiation monitor by holding the
probe perpendicular to the surface being measured
Move probe along shaded area
Probe scanning speed
Less than 2.5 cm/sec
( 1in/sec)
5-1
SERVICE INFORMATION
TOOLS AND MEASURING INSTRUMENTS
MICROWAVE LEAKAGE TEST
Page of 36