—9—
2.2 AIR HANDLING PARTS
2.2.1 COVER (AT THE TOP)
1. Remove the front grille. (Refer to section 2.1.1)
2. Remove the cabinet. (Refer to section 2.1.2)
3. Remove 11 screws which fasten the brace and
covers.
4. Remove the covers and the brace. (See figure 4)
5. Re-install the components by referring to the
removal procedure, above.
2.2.2 BLOWER
1. Remove the cover. (Refer to section 2.2.1)
2. Remove the 3 screws which fasten the evaporator
at the left side and the top side.
3. Move the evaporator sideward carefully.
4. Remove the orifice from the air guide carefully.
5. Remove the clamp which secures the blower with
plier. (See figure 5)
6. Remove the blower with plier or your hand without
touching blades. (See figure 6)
7. Re-install the components by referring to the
removal procedure, above.
2.2.3 FAN
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the brace and shroud cover. 
(Refer to section 2.2.1)
3. Remove the 5 screws which fasten the condenser.
4. Move the condenser sideways carefully.
5. Remove the clamp which secures the fan.
6. Remove the fan. (See figure 7)
7. Re-install the components by referring to the
removal procedure, above.
Figure 4
Figure 5
Figure 6
Figure 7
—10—
2.2.4 SHROUD
1. Remove the fan. (Refer to section 2.2.3)
2. Remove the 2 screws which fasten the shroud.
3. Remove the shroud. (See figure 8)
4. Re-install the component by referring to the
removal procedure, above.
2.3 ELECTRICAL PARTS
2.3.1 MOTOR
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the cover control and disconnect a wire
housing in control box. (Refer to section 2.1.3)
3. Remove the blower. (Refer to section 2.2.2)
4. Remove the fan. (Refer to section 2.2.3)
5. Remove the 4 screws which fasten the motor.
(See figure 9)
6. Remove the motor.
7. Re-install the components by referring to the
removal procedure, above.
2.3.2 COMPRESSOR
1. Remove the cabinet. (Refer to section 2.1.2)
2. Discharge the refrigerant system using Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
TM 
. Leave the valve in place after 
servicing the system.
3. Disconnect the 3 leads from the compressor.
4. After purging the unit completely, unbrace the
suction and discharge tubes at the compressor
connections.
5. Remove the 3 nuts and the 3 washers which
fasten the compressor.
6. Remove the compressor. (See figure 10)
7. Re-instill the components by referring to the
removal procedure, above.
Figure 8
Figure 9
Figure 10
—11—
2.3.3 CAPACITOR
1. Remove the control box. (Refer to section 2.1.3)
2. Remove the screw and knobs which fasten the
display panel.
3. Disconnect the 2 leads from the rocker switch.
4. Disconnect the lamp lead from the terminal block
and remove the panel.
5. Remove a screw and unfold the control box. 
(See figure 11)
6. Remove the screw and the clamp which fastens
the capacitor. (See figure 11)
7. Disconnect all the leads of capacitor terminals.
8. Re-install the components by referring to the
removal procedure, above.
2.3.4 POWER CORD
1. Remove the control box. (Refer to section 2.1.3)
2. Unfold the control box. (Refer to section 2.3.3)
3. Disconnect the grounding screw from the control
box.
4. Disconnect 2 receptacles.
5. Remove a screw which fastens the clip cord.
6. Pull the power cord. (See figure 12)
7. Re-install the component by referring to the
removal procedure, above.
(Use only one ground-marked hole      for ground
connection.)
8. If the supply cord of this appliance is damaged, it
must be replaced by the special cord. 
(The special cord means the cord which has the
same specification marked on the supply cord
fitted to the unit.)
2.3.5 THERMOSTAT
1. Remove the control box. (Refer to section 2.1.3)
2. Unfold the control box. (Refer to section 2.3.3)
3. Remove the 2 screws which fasten the thermostat.
4. Disconnect all the leads of thermostat terminals.
5. Remove the thermostat. (See figure 13)
6. Re-install the components by referring to the
removal procedure, above.
Figure 12
Figure 11
Figure 13
2.3.6 ROTARY SWITCH
1. Remove the control box. (Refer to section 2.1.3)
2. Unfold the control box. (Refer to section 2.3.3)
3. Remove 2 screws which fasten the rotary switch.
4. Disconnect all the leads of the rotary switch
terminals.
5. Remove the rotary switch. (See figure 14)
6. Re-install the components by referring to the
above removal procedure, above.
2.3.7 SYNCHRONOUS MOTOR
1. Remove the control box. (Refer to section 2.1.3)
2. Unfold the control box. (Refer to section 2.3.3)
3. Remove the cam.
4. Disconnect all the leads of the synchronous
motor.
5. Remove the 2 screws which fasten the
synchronous motor. (See figure 15)
6. Re-install the components by referring to the
removal procedure, above.
2.3.8 REVERSING VALVE ASSY
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the reversing coil from the reversing valve
assembly by loosening the screw.
3. Discharge the refrigerant system using a Freon
TM
recovery system.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
TM
.
Leave the valve in place after servicing.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the reversing
vlave assembly connections.
5. Re-install the components by referring to the
removal procedure, above.
Notes:
When connect the reversing valve assembly,
braze the reversing valve and inter-connecting
tube immersing in water not to make the tempera-
ture of surface exceed more than 120°C(248°F)
—12—
Figure 15
Figure 16
Figure 14
Reversing valve
Reversing coil
Page of 67
Display

Click on the first or last page to see other LWM1560BHE / LWM1861BHE / LWM1861BHG / LWN1862BHG / LWN2262BHG service manuals if exist.