—3—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)  
(mm)
7,000
755
3.4
9.0
27(DB)*
19(WB)**
35(DB)*
24(WB)**
290g (10.2 Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
1 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
3/3
4 POLES
ROTARY SWITCH
TOUCH & REMOTE CONTROL
THERMOSTAT
THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
75/34
18
1
/
2
x 13
7
/
x 20
11
/
16
470 x 353 x 525
1ø, 220~240V~, 50Hz
LWG0760ACG LWG0760BCG
LWG0760PCG LWG0760QCG
MODELS
ITEMS
OPERATING
CONDITION
1.3 SPECIFICATIONS
1.3.1 LWG0760ACG, LWG0760BCG, LWG0760PCG, LWG0760QCG
* DB:Dry Bulb
** WB:Wet Bulb
—4—
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
E.E.R (BTU/W.h)
INDOOR (°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT (lbs/kg)
OUTSIDE DIMENSION (inch)
(W x H x D)   (mm)
9,000
1,000
4.2
9.0
27(DB)* 19(WB)**
35(DB)* 24(WB)**
390g (13.8 Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
1 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3 3/3
4 POLES
ROTARY SWITCH TOUCH & REMOTE CONTROL
THERMOSTAT THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
75/34
18
1
/
2
x 13
7
/
x 20
11
/
16
470 x 353 x 525
1ø, 115, 220~240V~, 50Hz
LWG0960ACG       LWG0960BCG       LWG0960PCG       LWG0960QCG
MODELS
ITEMS
OPERATING
CONDITION
1.3 SPECIFICATIONS
1.3.1 LWG0960ACG, LWG0960BCG, LWG0960PCG, LWG0960QCG
* DB:Dry Bulb
** WB:Wet Bulb
1.4 FEATURES
• Designed for COOLING ONLY.
• Powerful and whispering cooling.
• Slide-in and slide-out chassis for the simple
installation and service.
• Side air-intake, side cooled-air discharge.
1.5 CONTROL LOCATIONS
1.5.1 COOLING ONLY MODEL
• VENTILATION
The ventilation lever must be in the CLOSE position
in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever OPEN position.
The damper is opened and room air is exhausted.
• THERMOSTAT
Thermostat will automatically control the
temperature of the room. Select a higher number for
a cooler temperature in the room. The temperature
is selected by positioning the knob to the desired
position.
The or position is a normal setting for average
conditions.
• OPERATION
OFF
(         )  : Turns the air conditioner to
off.
MED FAN
(         )  : Permits the medium fan
speed operation without
cooling.
LOW FAN
(         )  : Permits the low fan speed
operation without cooling.
HIGH COOL (         )  : Permits cooling with the high
fan speed operation.
MED COOL
(         )  : Permits cooling with the
medium fan speed operation.
LOW COOL  (         )  : Permits cooling with the low
fan speed operation.
• Built-in adjustable THERMOSTAT
• Washable one-touch filter
• Compact size
• Reliable and efficient rotary compressor is equipped.
—5—
CLOSE
VENT
OPEN
Operation
Off
Med
Fan
Low
Fan
Low Cool
Med
Cool
High
Cool
Thermostat
5
4
3
2
1
6
7
8
9
• AUTO SWING
OFF
(         )  : Air swing is operated
automatically while “AUTO
SWIMG” knob is set to “ON”
position.
on
(         )  : Stops the operation of auto
swing.
• OPERATION
HIGH COOL (         )  : Permits cooling with the high
fan speed operation.
LOW COOL
(         )  : Permits cooling with the low
fan speed operation.
• TIME
The timer can control the operation times within 6
hours. If you set the timer switch at the “1” position,
after 1 hour the unit will be stopped automatically. If
you want tho operate continuously, set the timer
swich at the “CONSTANT” position.
The timer switch cannot rotate further clockwise from
the “CONSTANT” position. If you set the timer
swittch at the “STOP” position, the unit will be
stopped all operations.
—6—
OFF
ON
Auto Swing
Med
Fan
Off
Low
Fan
High
Cool
Med
Cool
Low Cool
6
7
8
9
5
1
2
3
4
High
Low
Operation
6
7
8
9
5
1
2
3
4
Stop
1
2
3
Constant
6
5
4
Thermostat
Timer
Page of 66
Display

LG LWG0760ACG / LWG0760QCG / LWG0820ACG / LWG0821ACG / LWG0960AAG / LWG0960ACG / LWG0960ACN / LWG0960ACS / LWG0960QAS / LWG0960QCG / LWG0960QAG / KC10WR / LWG0761PCG Service Manual ▷ Download

  • DOWNLOAD LG LWG0760ACG / LWG0760QCG / LWG0820ACG / LWG0821ACG / LWG0960AAG / LWG0960ACG / LWG0960ACN / LWG0960ACS / LWG0960QAS / LWG0960QCG / LWG0960QAG / KC10WR / LWG0761PCG Service Manual ↓ Size: 2.7 MB | Pages: 66 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LWG0760ACG / LWG0760QCG / LWG0820ACG / LWG0821ACG / LWG0960AAG / LWG0960ACG / LWG0960ACN / LWG0960ACS / LWG0960QAS / LWG0960QCG / LWG0960QAG / KC10WR / LWG0761PCG in PDF for free, which will help you to disassemble, recover, fix and repair LG LWG0760ACG / LWG0760QCG / LWG0820ACG / LWG0821ACG / LWG0960AAG / LWG0960ACG / LWG0960ACN / LWG0960ACS / LWG0960QAS / LWG0960QCG / LWG0960QAG / KC10WR / LWG0761PCG Air Conditioner. Information contained in LG LWG0760ACG / LWG0760QCG / LWG0820ACG / LWG0821ACG / LWG0960AAG / LWG0960ACG / LWG0960ACN / LWG0960ACS / LWG0960QAS / LWG0960QCG / LWG0960QAG / KC10WR / LWG0761PCG Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.