—4—
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
E.E.R (BTU/W.h)
INDOOR (°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT (lbs/kg)
OUTSIDE DIMENSION (inch)
(W x H x D)   (mm)
9,000
1,000
4.2
9.0
27(DB)* 19(WB)**
35(DB)* 24(WB)**
390g (13.8 Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
1 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3 3/3
4 POLES
ROTARY SWITCH TOUCH & REMOTE CONTROL
THERMOSTAT THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
75/34
18
1
/
2
x 13
7
/
x 20
11
/
16
470 x 353 x 525
1ø, 115, 220~240V~, 50Hz
LWG0960ACG       LWG0960BCG       LWG0960PCG       LWG0960QCG
MODELS
ITEMS
OPERATING
CONDITION
1.3 SPECIFICATIONS
1.3.1 LWG0960ACG, LWG0960BCG, LWG0960PCG, LWG0960QCG
* DB:Dry Bulb
** WB:Wet Bulb
1.4 FEATURES
• Designed for COOLING ONLY.
• Powerful and whispering cooling.
• Slide-in and slide-out chassis for the simple
installation and service.
• Side air-intake, side cooled-air discharge.
1.5 CONTROL LOCATIONS
1.5.1 COOLING ONLY MODEL
• VENTILATION
The ventilation lever must be in the CLOSE position
in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever OPEN position.
The damper is opened and room air is exhausted.
• THERMOSTAT
Thermostat will automatically control the
temperature of the room. Select a higher number for
a cooler temperature in the room. The temperature
is selected by positioning the knob to the desired
position.
The or position is a normal setting for average
conditions.
• OPERATION
OFF
(         )  : Turns the air conditioner to
off.
MED FAN
(         )  : Permits the medium fan
speed operation without
cooling.
LOW FAN
(         )  : Permits the low fan speed
operation without cooling.
HIGH COOL (         )  : Permits cooling with the high
fan speed operation.
MED COOL
(         )  : Permits cooling with the
medium fan speed operation.
LOW COOL  (         )  : Permits cooling with the low
fan speed operation.
• Built-in adjustable THERMOSTAT
• Washable one-touch filter
• Compact size
• Reliable and efficient rotary compressor is equipped.
—5—
CLOSE
VENT
OPEN
Operation
Off
Med
Fan
Low
Fan
Low Cool
Med
Cool
High
Cool
Thermostat
5
4
3
2
1
6
7
8
9
• AUTO SWING
OFF
(         )  : Air swing is operated
automatically while “AUTO
SWIMG” knob is set to “ON”
position.
on
(         )  : Stops the operation of auto
swing.
• OPERATION
HIGH COOL (         )  : Permits cooling with the high
fan speed operation.
LOW COOL
(         )  : Permits cooling with the low
fan speed operation.
• TIME
The timer can control the operation times within 6
hours. If you set the timer switch at the “1” position,
after 1 hour the unit will be stopped automatically. If
you want tho operate continuously, set the timer
swich at the “CONSTANT” position.
The timer switch cannot rotate further clockwise from
the “CONSTANT” position. If you set the timer
swittch at the “STOP” position, the unit will be
stopped all operations.
—6—
OFF
ON
Auto Swing
Med
Fan
Off
Low
Fan
High
Cool
Med
Cool
Low Cool
6
7
8
9
5
1
2
3
4
High
Low
Operation
6
7
8
9
5
1
2
3
4
Stop
1
2
3
Constant
6
5
4
Thermostat
Timer
—7—
TEMPERATURE SETTING
• This button can automatically control the temperature of the room.
  The temperature can be set within a range of 60
°
F to 86
°
F by 1
°
F.(16˚C to 30˚C by 1˚C)
  Select the lower number for lower temperature of the room.
FAN SPEED
• Everytime you push this button it is set as follows. {High(F3)  Low(F1)  Med(F2)  High(F3)...}.
FAN SPEED
• Everytime you push this button it is set as follows.
 
 
{High(F3) Low(F1) Med(F2) High(F3)...}.
POWER
• To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again.
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72
°
F(22˚C).
MODE
• Everytime you push this button, it will toggle between COOL and FAN.
AUTO SWING
• The vertical louver swings horizontally by the automatic system and stops when you press
  the button again.
ON/OFF TIMER
- STOPPING OPERATION
• Everytime you push this button,  when the air conditioner is operating, timer is set as follows. 
  (1Hour    2Hours    3Hours    4Hours    5Hours    6Hours    7Hours    8Hours    9Hours
  10Hours    11Hours    12Hours    Cancel)
• The Setting Temperature will be raised by 2
°
F(1
°
C) 30min. later and by 2
°
F(1
°
C) after another 30 min.
- STARTING OPERATION
• Everytime you push this button, when the air conditioner is not operating, timer is set as follow. 
  (1Hour    2Hours    3Hours    4Hours    5Hours    6Hours    7Hours    8Hours    9Hours
  10Hours    11Hours    12Hours    Cancel)
REMOCON SIGNAL RECEIVER
MODE
• Everytime you push this button, it will toggle
  between COOL and FAN.
POWER
• To turn the air conditioner ON, push the button.
  To turn the air conditioner OFF, push the button again.
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the
  High cool mode and the temp. at 72
°
F(22˚C)
TEMPERATURE SETTING
• This button can automatically control the temperature
  of the room. The temperature can be set within a range
  of 60
°
F to 86
°
F by 1
°
F.(16˚C to 30˚C by 1˚C)
  Select the lower number for lower temperature of the room.
AUTO RESTART SWITCH
In failure of electric power, if the switch is set to "ON",
the unit runs unit runs as previous setting operation
when power returns.
AUTO SWING
The vertical louver swings horizontally by the automatic
system and stops when you press the button again.
ON/OFF TIMER
• Everytime you push this button, timer is set as follows. 
  (1Hour    2Hours    3Hours    4Hours    5Hours    6Hours
  7Hours    8Hours    9Hours    10Hours    11Hours    12Hours    Cancel)
• The Setting Temperature will be raised by 2
°
F(1˚C) 30min.
   later and by 2
°
F after another 30 min.
1.5.2 COOLING ONLY MODEL WITH REMOTE CONTROL AND TOUCH TYPE
• DISPLAY
• REMOTE CONTROLLER
Precaution: The Remote Controller will not function properly if strong light strikes the sensor window of the air
conditioner or if there are obstacles between the Remote Controller and the air conditioner.
Page of 29
Display

LG LWG0760ACG / LWG0760ACG / LWG0760BCG / LWG0960ACG / LWG0960BCG Service Manual ▷ Download

  • DOWNLOAD LG LWG0760ACG / LWG0760ACG / LWG0760BCG / LWG0960ACG / LWG0960BCG Service Manual ↓ Size: 912.23 KB | Pages: 29 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LWG0760ACG / LWG0760ACG / LWG0760BCG / LWG0960ACG / LWG0960BCG in PDF for free, which will help you to disassemble, recover, fix and repair LG LWG0760ACG / LWG0760ACG / LWG0760BCG / LWG0960ACG / LWG0960BCG Air Conditioner. Information contained in LG LWG0760ACG / LWG0760ACG / LWG0760BCG / LWG0960ACG / LWG0960BCG Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.