LG LWG0710PCG / LWG0720NCN / LWG0720PCG / LWG0760ACG_ACP / LWG0760BCG / LWG0760PCG / LWG0760QCG / LWG0761ACG_ACE_AAG_PCG_ACP_ACF / LWG0761BCE_BCN_BAG / LWG0761QAG / LWG0820ACG_SAS_NCE / LWG0821ACG_LWG0911AAG / LWG0960ACG_ACS_ACN_AAG_ACP_ACF / LWG0960BCW07LC Service Manual ▷ View online
—4—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
9,000 (7,000)
1,000
9.2
4.2/4.4
9.0
27(DB)*
19(WB)**
35(DB)*
24(WB)**
330g (11.6 Oz)
390g (13.8 Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
2 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
3/3
4 POLES
ROTARY SWITCH
TOUCH & REMOTE CONTROL
THERMOSTAT
THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
75/34
18
1
/
2
x 13
7
/
8
x 20
11
/
16
470 x 353 x 525
1ø, 220-240V~, 50Hz
1ø, 115V, 60Hz
LWG0960ACG/
AAG/ACS/ACN/ACF
KC10WR
LWG0911AAG
LWC091GSAA0
LWG0960BCG/
BAG
LWG0960PA
G/PCG/PCN
LWG0960QCG/
QAG
MODELS
ITEMS
OPERATING
CONDITION
* DB:Dry Bulb
** WB:Wet Bulb
** WB:Wet Bulb
—5—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
1ø, 220V~, 60Hz
1ø, 115V~, 60Hz
8,000
7000
870
760
720
4.1
3.6
6.6
9.2
9.7
27(DB)*
19.5(WB)**
35(DB)*
24(WB)**
350g (12.3 Oz)
290g(10.2Oz)
370g(13Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
2 ROW 16 STACKS, LOUVERED-FIN TYPE
1 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
3/3
2/3
3/3
2/3
6 POLES
ROTARY SWITCH
TOUCH & REMOTE CONTROL
ROTARY SWITCH
TOUCH & REMOTE CONTROL
ROTARY SWITCH
THERMOSTAT
THERMISTOR
THERMOSTAT
THERMISTOR
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
71/32
66/30
18
1
/
2
x 13
7
/
8
x 20
11
/
16
470 x 353 x 525
LWG0720PCG LWG0720NCN LWG0710PCG
LWG0820ACG
LWG0820SAS
LWG0820NCE
MODELS
ITEMS
OPERATING
CONDITION
* DB:Dry Bulb
** WB:Wet Bulb
** WB:Wet Bulb
—6—
POWER SUPPLY
COOLING CAPACITY
(Kcal/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(Kcal/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
1,800
710
3.3
2.535
27(DB)*
19.5(WB)**
35(DB)*
24(WB)**
370g (13.0 Oz)
2 ROW 14 STACKS, SLIT-FIN TYPE
2 ROW 16 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
0/2
6 POLES
ROTARY SWITCH
ROCKER SWITCH
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
64/29
18
1
/
2
x 13
7
/
8
x 20
11
/
16
470 x 353 x 525
1ø, 220V~, 60Hz
LWG0821ACG
LWG0821DCG
MODELS
ITEMS
OPERATING
CONDITION
1.4 LWG0821ACG, LWG0821DCG
* DB:Dry Bulb
** WB:Wet Bulb
** WB:Wet Bulb
—7—
TEMPERATURE SETTING
• This button can automatically control the temperature of the room.
The temperature can be set within a range of 60
The temperature can be set within a range of 60
°
F to 86
°
F by 1
°
F.(16˚C to 30˚C by 1˚C)
Select the lower number for lower temperature of the room.
FAN SPEED
• Everytime you push this button it is set as follows. {High(F3)
→
Low(F1)
→
Med(F2)
→
High(F3)...}.
FAN SPEED
• Everytime you push this button it is set as follows.
{High(F3)
{High(F3)
→
Low(F1)
→
Med(F2)
→
High(F3)...}.
POWER
• To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again.
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72
°
F(22˚C).
MODE
• Everytime you push this button, it will toggle between Cool, Fan and Dry.
AUTO SWING
• The vertical louver swings horizontally by the automatic system and stops when you press
the button again.
the button again.
ON/OFF TIMER
REMOCON SIGNAL RECEIVER
MODE
• Everytime you push this button, it will toggle
between Cool, Fan and Dry.
between Cool, Fan and Dry.
POWER
• To turn the air conditioner ON, push the button.
To turn the air conditioner OFF, push the button again.
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the
High cool mode and the temp. at 72
To turn the air conditioner OFF, push the button again.
• This button takes priority over any other buttons.
• When you first turn it on, the air conditioner is on the
High cool mode and the temp. at 72
°
F(22˚C)
TEMPERATURE SETTING
• This button can automatically control the temperature
of the room. The temperature can be set within a range
of 60
of the room. The temperature can be set within a range
of 60
°
F to 86
°
F by 1
°
F.(16˚C to 30˚C by 1˚C)
Select the lower number for lower temperature of the room.
AUTO SWING
The vertical louver swings horizontally by the automatic
system and stops when you press the button again.
system and stops when you press the button again.
ON/OFF TIMER
• Everytime you push this button, timer is set as follows.
(1Hour
(1Hour
→
2Hours
→
3Hours
→
4Hours
→
5Hours
→
6Hours
7Hours
→
8Hours
→
9Hours
→
10Hours
→
11Hours
→
12Hours
→
Cancel)
• The Setting Temperature will be raised by 2
°
F(1˚C) 30min. later and by 2
°
F after another 30 min.
• Remote controller
Precaution: The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or
if there are obstacles between the Remote Controller and the air conditioner.
1
2
3
4
5
6
1
2
3
4
5
6
1
4
5
3
6
2
- STOPPING OPERATION
• Everytime you push this button, when the air conditioner is operating, timer is set as follows. (1Hour
• Everytime you push this button, when the air conditioner is operating, timer is set as follows. (1Hour
→
2Hours
→
3Hours
→
4Hours
→
5Hours
→
6Hours
→
7Hours
→
8Hours
→
9Hours
→
10Hours
→
11Hours
→
12Hours
→
Cancel)
• The Setting Temperature will be raised by 2
°
F(1
°
C) 30min. later and by 2
°
F(1
°
C) after another 30 min.
- STARTING OPERATION
• Everytime you push this button, when the air conditioner is not operating, timer is set as follow.
(1Hour
• Everytime you push this button, when the air conditioner is not operating, timer is set as follow.
(1Hour
→
2Hours
→
3Hours
→
4Hours
→
5Hours
→
6Hours
→
7Hours
→
8Hours
→
9Hours
10Hours
→
11Hours
→
12Hours
→
Cancel)
2. COOLING ONLY MODEL WITH REMOTE CONTROL AND TOUCH TYPE
• DISPLAY
AUTO RESTART
In failure of electric power, the unit runs as previous setting operation when power returns.
In failure of electric power, the unit runs as previous setting operation when power returns.