3. INSTALLATION
3.1 SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the unit
in installed securely and firmly.
2. Install the unit where the sunlight does not shine
directly on the unit.
3. The outside of the cabinet must extend outward for
at least 10" and there should be no obstacles, such
as a fence or wall, within 20" from the back of the
cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency, of the air condditioner.
4. Install the unit a little slanted so the back is slightly
lower than the front (about 
1
/
2
"). This will force con-
densed water to the outside.
5. Install the unit with the bottom about 30"~60" above
the floor level.
3.2 INSTALLATION INSTRUCTIONS
1. Remove the screws which fasten the cabinet 
at both sides and at the back.
2. Slide the unit from the cabinet by gripping the 
base pan handle and pulling forward while 
bracing the cabinet.
3. Remove EPS Material.
Ñ
14
Ñ
All side louvers of the cabinet must remain
exposed to the outside of the structure.
AWNING
COOLED AIR
HEAT
RADIATION
ABOUT 
1
/
2
"
30"~60"
Over 20"
FENCE
Shipping screws
EPS Material
Figure 19
Figure 20
Figure 21
Figure 22
CAUTION
Ñ
15
Ñ
4. Slide the unit into the cabinet.
CAUTION: For security purpose, reinstall screw at
cabinet's sides.
5. Attach the front grille to the cabinet by 
inserting the tabs on the grille into the tabs on the
fornt of the cabinet. Push the grille in until it snaps
into place.
6. Lift the inlet grille and secure it with a screw
through the front grille.
4. TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS                            
unit: mm(inch)
600(23 
5
/
8
")
555(21 
27
/
32
")
380(14 
31
/
32
")
219(8 
5
/
8
")
600(23 
5
/
8
")
567(21 
5
/
16
")
380(14 
31
/
32
")
219(8 
5
/
8
")
Power cord
Screw
Screw
Figure 23
Figure 24
LW - C0966HL
LW - C1266HL
LWC0960AHL
LWC1260AHL
LW - C0967HL
LW - C1267HL
LWC0960PHL
LWC1260PHL
LWC0960AHG
LWC1260AHG
LWC0960PHG
LWC1260PHG
Ñ
15
Ñ
4. Slide the unit into the cabinet.
CAUTION: For security purpose, reinstall screw at
cabinet's sides.
5. Attach the front grille to the cabinet by 
inserting the tabs on the grille into the tabs on the
fornt of the cabinet. Push the grille in until it snaps
into place.
6. Lift the inlet grille and secure it with a screw
through the front grille.
4. TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS                            
unit: mm(inch)
600(23 
5
/
8
")
555(21 
27
/
32
")
380(14 
31
/
32
")
219(8 
5
/
8
")
600(23 
5
/
8
")
567(21 
5
/
16
")
380(14 
31
/
32
")
219(8 
5
/
8
")
Power cord
Screw
Screw
Figure 23
Figure 24
LW - C0966HL
LW - C1266HL
LWC0960AHL
LWC1260AHL
LW - C0967HL
LW - C1267HL
LWC0960PHL
LWC1260PHL
LWC0960AHG
LWC1260AHG
LWC0960PHG
LWC1260PHG
Ñ
24
Ñ
COMPLAINT
CAUSE
REMEDY
Check voltage. See the limits on the preceding
page. If not within limits, call an electrician.
Check the wire connections, if loose, repair or
replace the terminal. If wires are off, refer to wiring
diagram for identification, and replace. Check wire
locations. If not per wiring diagram, correct.
Check for continuity, refer to the wiring diagram
for terminal identification. Replace the switch if
circuit is open.
Check the position of knob If not at the coldest
setting, advance the knob to this setting and
restart unit.
Check continuity of the thermostat. Replace
thermostat if circuit is open.
Check the capacitor.
Replace if not within ±10% of manufacturers
rating. Replace if shorted, open, or damaged.
Check the compressor for open circuit or
ground. If open or grounded, replace the
compressor.
Check the compressor overload, if externally
mounted. Replace if open. (If the compressor
temperature is high, remove the overload, cool it,
and retest.)
Check the voltage. See the limits on the preced-
ing page. If not within limits, call an electrician.
Check overload, if externally mounted.
Replace if open. (If the compressor temperature
is high, remove the overload, cool, and retest.)
If not running, determine the cause. Replace if
required.
Remove the cabinet. Inspect the interior surface
of the condenser; if restricted, clean carefully
with a vacuum cleaner (do not damage fins) or
brush. Clean the interior base before
reassembling.
If condenser fins are closed over a large area
on the coil surface, head pressures will increase,
causing the compressor to cycle. Straighten the
fins or replace the coil.
Test capacitor.
Check the terminals. If loose, repair or replace.
Voltage
Wiring
Rotary switch
Thermostat
Capacitor (Discharge
capacitor before
servicing.)
Compressor
Overload
Voltage
Overload
Fan motor
Condenser air flow
restriction.
Condenser fins
(damaged).
Capacitor
Wiring
Compressor will not run,
but fan motor runs.
Compressor cycles
on overload.
Compressor cycles on
overload (Cont'd)