—2—
1. PREFACE
1.1 SAFETY PRECAUTIONS................................2
1.2 INSULATION RESISTANCE TEST .................2
1.3 SPECIFICATIONS...........................................3
1.4 FEATURES......................................................7
1.5 CONTROL LOCATIONS .................................7
2. DISASSEMBLY INSTRUCTIONS
2.1 MECHANICAL PARTS ..................................12
2.1.1 FRONT GRILLE ...................................12
2.1.2 CABINET ..............................................12
2.1.3 CONTROL BOX ...................................12
2.2 AIR HANDLING PARTS ................................13
2.2.1 AIR GUIDE AND BLOWER ..................13
2.2.2 FAN ......................................................13
2.2.3 SHROUD ..............................................14
2.3 ELECTRICAL PARTS....................................14
2.3.1 OVERLOAD PROTECTOR ..................14
2.3.2 COMPRESSOR....................................14
2.3.3 CAPACITOR.........................................15
2.3.4 POWER CORD ....................................15
2.3.5 THERMOSTAT .....................................15
2.3.6 ROTARY SWITCH ...............................15
2.3.7 MOTOR ................................................16
2.4 REFRIGERATING CYCLE ............................16
2.4.1 CONDENSER.......................................16
2.4.2 EVAPORATOR.....................................16
2.4.3 CAPILLARY TUBE ...............................17
3. INSTALLATION
3.1 SELECT THE BEST LOCATION...................19
3.2 CHECK OF INSTALLATION..........................19
3.3 HOW TO DRAIN............................................19
3.4 HOW TO INSTALL ........................................20
4. TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS ...............................22
4.2 PIPING SYSTEM...........................................22
4.3 TROUBLESHOOTING GUIDE ......................23
5. SCHEMATIC DIAGRAM
5.1 CIRCUIT DIAGRAM ......................................33
5.2 ELECTRONIC CONTROL DEVICE...............38
5.3 COMPONENTS LOCATION (FOR MAIN P.C.B ASM)......40
5.4 COMPONENTS LOCATION (FOR DISPLAY P.C.B ASM)  ....40
6. EXPLODED VIEW
..................................41
7. REPLACEMENT PARTS LIST
........42
1. PREFACE
This 
SERVICE MANUAL
provides various service information, including the mechanical and electrical
parts etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
1. When servicing the unit, set the ROTARY SWITCH
or POWER SWITCH to OFF and unplug the power
cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing the unit, make an insulation resis-
tance test to protect the customer from being
exposed to shock hazards.
1.2 INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (green) is to be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all the positions
(except OFF) of the ROTARY SWITCH.
4. The value should be over 1M
.
CONTENTS
—3—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W 
D)  
(mm)
10,000
12,000
1,050
1,260
9.5
11.5
9.5
26.7(DB)*
19.4(WB)**
35(DB)*
23.9(WB)**
490g (17.3 Oz)
480g (17 Oz)
2 ROW 16 STACKS, SLIT-FIN TYPE
2 ROW 13 STACKS, LOUVERED-FIN TYPE
2 ROW 17 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3
2/2
2/3
2/2
6 POLES
ROTARY SWITCH
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.8m(7") (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
90/41
95/43
23
5
/
8
x 14
31
/
32 
x 21
7
/
8
600 x 380 x 555
1ø, 115, 60Hz
LWC1010ACL
LWC1010MCL
LWC1210ACL
LWC1210PCL
LWC1010ACG
LWC1010MCG
LWC1210ACG
LWC1210PCG
MODELS
ITEMS
OPERATING
CONDITION
1.3 SPECIFICATIONS
1.3.1 FOR LWC1010ACL, LWC1010MCL, LWC1210ACL, LWC1210PCL
LWC1010ACG, LWC1010MCG, LWC1210ACG, LWC1210PCG
* DB:Dry Bulb
** WB:Wet Bulb
—4—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W 
H  
D)  
(mm)
10,000
1,050
5.0
9.5
27(DB)*        19.5(WB)**
35(DB)*           24(WB)**
510g (18 Oz)
2 ROW 16 STACKS SLIT-FIN TYPE
2 ROW 17 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
2/3 0/2
2/2
6 POLES
ROTARY SWITCH OR ROCKER SWITCH
WIRELESS REMOCON
THERMOSTAT
THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.8m(7") (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
90/41
23
5
/
8
x 14
31
/
32 
x 21
7
/
8
600 x 380 x 555
1ø, 208/230V, 60Hz
LWC1030ACL
LWC1030DCL
LWC1030PCL
LWC1030NCL
LWC1030ACG
LWC1030DCG
LWC1030PCG
LWC1030NCG
MODELS
ITEMS
OPERATING
CONDITION
1.3.2 FOR LWC1030ACL, LWC1030DCL, LWC1030PCL, LWC1030NCL
LWC1030ACG, LWC1030DCG, LWC1030PCG, LWC1030NCG
* DB:Dry Bulb
** WB:Wet Bulb
—5—
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR 
COMPRESSOR
FAN MOTOR          
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W 
H  
D)  
(mm)
12,000
1,300
6.2
9.2
27(DB)*        19.5(WB)**
35(DB)*           24(WB)**
490g (17.3 Oz)
2 ROW 16 STACKS SLIT-FIN TYPE
2 ROW 17 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
0/2
2/2
6 POLES
ROTARY SWITCH OR ROCKER SWITCH
WIRELESS REMOCON
THERMOSTAT
THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.8m(7") (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
95/43
23
5
/
8
x 14
31
/
32 
x 21
7
/
8
600 x 380 x 555
1ø, 208/230V, 60Hz
LWC1230ACL
LWC1230DCL
LWC1230PCL
LWC1230NCL
LWC1230ACG
LWC1230DCG
LWC1230PCG
LWC1230NCG
MODELS
ITEMS
OPERATING
CONDITION
* DB:Dry Bulb
** WB:Wet Bulb
1.3.3 FOR LWC1230ACL, LWC1230DCL, LWC1230PCL, LWC1230NCL
LWC1230ACG, LWC1230DCG, LWC1230PCG, LWC1230NCG
Page of 127
Display

LG LWC1260ACG Service Manual ▷ Download

  • DOWNLOAD LG LWC1260ACG Service Manual ↓ Size: 3.43 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LWC1260ACG in PDF for free, which will help you to disassemble, recover, fix and repair LG LWC1260ACG Air Conditioner. Information contained in LG LWC1260ACG Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.