LG LWC1260ACG Service Manual ▷ View online

—18—
3. INSTALLATION
3.1 SELECT THE BEST LOCATION
1.To prevent vibration and noise, make sure the unit
in installed securely and firmly.
2.Install the unit where the sunlight does not shine
directly on the unit.
3.The outside of the cabinet must extend outward for
at least 12" and there should be no obstacles, such
as a fence or wall, within 20" from the back of the
cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air condditioner.
4.Install the unit a little slanted so the back is slightly
lower than the front (about 
1
/
2
"). This will force con-
densed water to the outside.
5.Install the unit with the bottom about 30"~60" above
the floor level.
3.2 CHECK OF INSTALLATION
The setting conditions must be checked prior to
initial starting.
The undermentioned items are especially important
checking points when the installation is finished.
1. Grounding wire (Green or Green and Yellow) is
provided in the power cord. The green wire must
be grounded.
2. Connect to a single-outlet 15AMP circuit.
3. To avoid vibration or noise, make sure the air
conditioner is installed securely.
4 Avoid placing furniture or draperies in front of the
air inlet and outlet.
3.3. HOW TO DRAIN
(When using drain pipe)
The air conditioner must be installed level or tilted
slightly to the outside for proper water drainage.
On exceptionally hot and humid days the air
conditioner may drain condensation through
overflow.
If the air conditioner is used in hot and a high
humidity zone, exchange the 
¥L
HOLE RUBBER
for the 
¥M
DRAIN PIPE.(See figure 19, figure 20.)
All side louvers of the cabinet must remain
exposed to the outside of the structure.
CAUTION
AWNING
COOLED AIR
HEAT
RADIATION
30"~60"
ABOUT 
1
/
2
"
Over 20"
FENCE
Figure 19
Figure 20
BASE PAN
HOLE RUBBER
DRAIN PIPE
1
BOTTOM
2
BASE PAN
BOTTOM
Figure 18
—19—
3.4 HOW TO INSTALL
3.4.1 WHEN USING GASKET
3.4.2 WHEN USING INSTALLATION KITS
A. WINDOW REQUIREMENTS
This unit is designed for installation in 
standard double hung windows with actual opening
widths from 27" to 39".
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of 16"
from the bottom of the upper sash to the window
stool.
A
B
D
E
F
C
H
2
3
1
4
2
1
A
RIGHT SIDE
HORIZONTAL
LINE
B
1. WINDOW (WIDTH-A, HEIGHT-B)
2. GASKET
3. WALL
4. DETAILS 5.1 x 30 ROUND HEAD WOOD
SCREWS
A
B
C
D
E
F
H
I
625mm
392mm
280mm
30mm
0~25mm
OVER 420mm
5~10mm
-5~5mm
(24
5
/
8
")
(15
7
/
16
")
(11
1
/
32
")
(1
1
/
16
")
(0~1")
(OVER 16
17
/
32
")
(
3
/
16
"~
3
/
8
")
(-
3
/
16
"~
3
/
16
")
1
2
3
4
8
9
11
7
6
5
10
13
12
NO.
NAME OF PARTS
Q'TY
1
FRAME CURTAIN
2
2
SILL SUPPORT
2
3
BOLT
2
4
NUT
2
5
SCREW(TYPE A)
16
6
SCREW(TYPE B)
3
7
SCREW(TYPE C)
5
8
FOAM-STRIP
1
9
FOAM-PE
1
10
UPPER GUIDE
1
11
FOAM-PE
1
12
FRAME GUIDE
2
13
WINDOW LOCKING BRACKET
1
B. INSTALLATION KITS CONTENTS
Stool
27" to 39"
16" min
Offset
1/2" to 1
1
/
4
"
Sill
Exterior
Interior wall
23
5
/
8
" min
(Without frame curtain)
—20—
SUGGESTED TOOL REQUIREMENTS
SCREWDRIVER(+, -), RULLER, KNIFE, HAMMER, PENCIL, LEVEL
PREPARATION OF CHASSIS
1. Remove the screws which fasten the cabinet at
both sides and at the back.
2. Slide the unit from the cabinet by gripping the base
pan handle and pulling forward while 
bracing the cabinet.
3. Remove EPS Material.
4. Cut the window sash seal to the proper length. Peel
off the backing and attach the foam-pe 
¤
to the
underside of the window sash.
5. Remove the backing from the top upper guide
Foam PE 
¤æ
and attach it to the bottom of the upper
guide 
¤ .
6. Attach the upper guide onto the top of the cabinet
with 3 type A screws.
7. Insert the frame guides 
¤
into the bottom of the
cabinet.
8. Insert the Frame Curtain 
¤
into the upper guide 
¤
and frame guides 
¤
.
9. Fasten the curtains to the unit with 4 Type A
screws.
CABINET INSTALLATION
1. Open the window. Mark a line on center of the
window stool(or desired air conditioner 
location).
Carefully place the cabinet on the window stool and
align the center mark on the bottom front with the
center line marked in the window stool.
2. Pull the bottom window sash down behind the
upper guide until it meets.
NOTE
• Do not pull the window sash down so tightly that the
movement of Frame Curtain is restricted.
9
10
11
10
5
5
5
12
12
Figure 21
Figure 22
(Type A)
Window stool
Upper guide 
¤
Window Sash
Foam-pe 
¤
Cabinet
Frame Curtain 
¤
Foam-pe 
¤æ
Front Angle
Upper Guide
(Type A)
Shipping screws
EPS Material
—21—
3. Loosely assemble the sill support using the parts
in 
Figure 
23.
4. Select the position that will place the sill 
support near the outer most point on sill
(See 
Figure 
24)
NOTE: Be careful when you install the cabinet (frame
guides 
¤
are broken so easily).
5. Attach the sill support to the cabinet track hole in
relation to the selected position using 
2 Type A screws in each support(See 
Figure 2
4).
6. The cabinet should be installed with a very slight
tilt(about 
1
/
2
") downward toward the outside (See
Figure 
25).
Adjust the bolt and the nut of sill support for
balancing the cabinet.
7. Attach the cabinet to the window stool by 
driving the screws 
¤
(Type B: Length sixteen
millimeters and below.) through the front angle into
window stool.
8. Pull each Frame curtain fully to each window sash
track, and repeat step 2.
9. Attach each Frame curtain the window sash using
screws 
¤
(Type C).
(See 
Figure
26)
Figure 23
Figure 24
Figure 25
Figure 26
Sill Support 
¤Ł
Nut 
¤Œ
Screw(Type A)
¤º
Screw(Type B)
¤
Screw(Type B)
¤
Sash track
Front Angle
Type C
¤
Sill support 
¤Ł
Sill support 
¤Ł
¤
Frame Guide
Cabinet
About 
1
/
2
"
About 
1
/
2
"
Bolt 
¤Ø
OUTDOOR
OUTDOOR
INDOOR
INDOOR
Page of 127