COMPLAINT
CAUSE
REMEDY
Check voltage at outlet. Correct if none.
Check voltage to rotary switch. If none, check
power supply cord. Replace cord if circuit is open.
Check switch continuity. Refer to wiring diagram
for terminal identification. Replace switch if none
defective.
Connect wire. Refer to wiring diagram for terminal
identification. Repair or replace loose terminal.
Test capacitor.
Replace if not within ±10% of manufacturer's
rating. Replace if shorted, open, or damaged.
Fan blade hitting shroud or blower wheel hitting
scroll. Realign assembly.
Units using slinger ring condenser fans must
have 
2
/
9
to 
1
/
4
inch clearance to the base. If it is
the base, shim up the bottom of the fan
motor with mounting screw(s).
Check fan motor bearings; if motor shaft will not
rotate, replace the motor.
Check voltage. See limits on this page. If not within
limits, call an electrician.
Test capacitor.
Check bearings. Does the fan blade rotate freely.
If not, replace fan motor.
Pay attention to any change from high speed to
low speed. If the speed does not change, replace
the motor.
No power
Power supply cord
Rotary switch
Wire disconnected or
connection loose
Capacitor (Discharge
capacitor before testing.)
Will not rotate
Revolves on overload.
Fan motor will not run.
Fan motor runs.
ROOM AIR CONDITIONER VOLTAGE LIMITS
NAME PLATE RATING 
MINIMUM
MAXIMUM
115V
103.5V
126.5V
220V ~ 240V
198V
264V
110V
99V
121V
—25—
COMPLAINT
CAUSE
REMEDY
If cracked, out of balance, or partially missing,
replace it.
If cracked, out of balance, or partially missing,
replace it.
Tighten it.
If knocking sounds continue when running or loose,
replace the motor. If the motor hums or noise
appears to be internal while running, replace motor.
Check voltage. See the limits on the preceding page.
If not within limits, call an electrician.
Check the wire connections ; if loose, repair or
replace the terminal. If the wires are disconnected,
refer to wiring diagram for identification, and replace
the wires. Check the wire connections ; if not
according to the wiring diagram, correct the
connections.
Check for continuity, refer to the wiring diagram for
terminal identification. Replace the switch if the
circuit is open.
Check the position of knob. If not at the coldest
setting, advance the knob to this setting and restart
the unit.
Check the continuity of the thermostat. Replace the
thermostat if the circuit is open.
Check the capacitor.
Replace if not within ±10% of manufacturer's rating,
replace if shorted, open, or damaged.
Check the compressor for open circuit or graond. If
open or grounded, replace the compressor.
Check the compressor overload if externally
mounted.
Replace if open. (If the compressor temperature is
high, remove the overload, cool and retest.)
Check the voltage. See the limits on the preceding
page. If voltage is not within these limits, call an
electrician.
Check overload, if externally mounted.
Replace if open. (If the compressor temperature is
high, remove the overload, cool, and retest.)
Fan
Blower
Loose set screw
Worn bearings
Voltage
Wiring
Rotary
Thermostat
Capacitor (Discharge
capacitor before
servicing.)
Compressor
Overload
Voltage
Overload
Fan motor noise.
Compressor will not run,
fan motor runs.
Compressor cycles on
overload.
—27—
5. SCHEMATIC DIAGRAM
5.1 CIRCUIT DIAGRAM
• MODEL : LWB0811CCL
MOTOR
COMP
WIRING DIAGRAM
3854AR3552E
POWER INPUT
ROTARY SWITCH
BK(BR)
WH(BL)
(Ribbed)
(Plain)
GN(GN/YL)
H
BK
RD
BL
BL
BK
BK
BK
BK
RD
RD
BL
BK
RD
BL
BK
RD
BL
YL
YL
L
M
OR(BR)
OR(BR)
T/BLOCK
OR
THERMOST
A
T
CAPACITOR
F
C
C
H
BR
R
S
C
OLP
P.T.C
MODE
SWITCH
WH
WH
1
2
3
1
2
3
4
5
6
7
8
2
12
10
13
9
3
4
11
16
15
5
14
6
7 8
17
S: Service Parts
O: Non Service Parts
LOCATION
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
POWER CORD ASS'Y
MOTOR ASS'Y
COMPRESSOR
ROTARY SWITCH
THERMOSTAT
CAPACITOR, SH
CONNECTOR ASS'Y (FOR COMP)
CONNECTOR ASS'Y (COMP)
CONNECTOR ASS'Y (FOR MOTOR)
T/BLOCK
OVERLOAD PROTECTOR
CONDUCTOR
CONDUCTOR
CONDUCTOR
CONDUCTOR
ROCKER SWITCH
(PTC)
2H00677R
4681A20010A
5416A20004A
2H00154H
2H01109H
6120AR2359S
6631AR2667H
6631AR2668F
6877A20001C
3H00390B
6750U-L030A
6862AR2348D
6862AR2348G
6862AR2348E
6862AR2348F
2H01316C
(2C00147B)
DESCRIPTION
PART NO.
LWB0811CCL
REMARKS
Q'TY
PER SET
—28—
• MODEL : LWB0810ACL/ LWB0810ACG
LWB0810ACL/ LWB0810ACG
PART NO.
2H00677R
4681A20010A
5614A20004A
2H00154H
2H01109H
6120AR2359S
6631AR2667H
6631AR2668F
6877A20001C
6750U-L030A
6862AR2187K
(2C00147B)
POWER CORD ASS'Y
MOTOR ASS'Y
COMPRESSOR
ROTARY SWITCH
THERMOSTAT
CAPACITOR, SH
CONNECTOR ASS'Y (FOR COMP)
CONNECTOR ASS'Y (COMP)
CONNECTOR ASS'Y (FOR MOTOR)
OVERLOAD PROTECTOR
CONDUCTOR
(PTC)
1
2
3
4
5
6
7
8
9
10
11
12
1
1
1
1
1
1
1
1
1
1
1
1
S
S
S
S
S
S
S
S
S
S
S
S
LOCATION
NO.
DESCRIPTION
REMARKS
Q'TY
PER SET
3854AR3552D
WIRING DIAGRAM
COMP
MOTOR
THERMOSTAT
CAPACITOR
ROTARY SWITCH
POWER INPUT
1
2
3
4
5
6
7
8
  
F
C
H
H
BK
RD
BL
BK
RD
BL
L
M
OR(BR)
OR(BR)
YL
YL
BR
R
S
C
BR
OLP
BK
RD
BL
BK
BK
RD
RD
BL
P.T.C
BK(BR)
(Plain)
WH(BL)
(Ribbed)
GN(GN/YL)
2
9
3
4
5
11
6
12
10
8
7
S: Service Parts
O: Non Service Parts
Page of 71
Display