— 3 —
1. PREFACE
This 
Service Manual
provides various service information, including the mechanical and electrical parts
etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 FEATURES
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT IN THE ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
1.2 SPECIFICATIONS
LW-A0560CL
LW-A0620CL
COOLING CAPACITY (BTU/h)
5,000
5,754
POWER SUPPLY (Phase, V, Hz)
1ø, 220/240V, 50Hz
1ø, 220V, 60Hz
INPUT (W)
610/625
589
OPERATING CURRENT (AMP.)
2.9/2.8
2.8
REFRIGERANT CONTROL
CAPILLARY TUBE
REFRIGERANT CHARGE (R-22)
255g (9.0 oz)
290g (10.2 oz)
INSIDE FAN
BLOWER
OUTSIDE FAN
PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE
2-WAY (RIGHT AND LEFT)
CHASSIS
TOP-DOWN
PROTECTOR
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
TEMPERATURE CONTROL
THERMOSTAT
ROTARY SWITCH
5 STEP (LOW FAN, HIGH-FAN, O(OFF), HIGH COOL, LOW COOL)
FAN MOTOR
6POLES, 25W
• NOTE : Specifications are subject to minor change without notice for further improvement.
— 4 —
1.3 LOCATIONS OF CONTROLS
OFF(O) 
- Turns air conditioner off.
HIGH FAN
- High speed fan operation without
cooling.
LOW FAN
- Low speed fan operation without
cooling.
HIGH COOL - Cooling with high speed fan operation.
LOW COOL  - Cooling with low speed fan operation.
This automatically controls the temperature of the
indoor air.
Turn the knob so that arrow points to the larger
marks for greater cooling. Point the arrow to the
smaller marks for more moderate cooling.
(i.e. the higher the number, the greater the cooling)
OPERATION
THERRMOSTAT
OPERATION
HIGH
HIGH
HIGH
HIGH
LOW
LOW LOW
LOW
FA
N
COO
L
OFF
FA
N
COO
L
O
COOLER
5
4
3
2
1
6
7
8
9
THERRMOSTAT
COOLER
5
4
3
2
1
6
7
8
9
CAUTION : After switching the air conditioner from COOL to OFF(O) or FAN, wait at least 3 minutes before
switching it back to COOL.
1.4 SAFETY PRECAUTIONS
1.5 INSULATION RESISTANCE TEST
1. When servicing, set the ROTARY SWITCH to OFF(O)
and unplug the power cord.
2. Oberve the original lead dress.
If a short circuit is found, replace all parts which have
been overheated or damaged by the short circuit.
3. After servicing, make an insulation resistance test to
prevent the customer from being exposed to shock
hazards.
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (green or green and
yellow) is to be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all position
(except OFF(O)) of the ROTARY SWITCH.
4. The value should be over 1M
.
3. INSTALLATION
This air conditioner is designed with a button-down
chassis so that it can be installed simply in a
window.
3-1. SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the unit
is installed securely and firmly.
2. Install the unit where the sunlight does not shine
directly on the unit.
3. The outside of the cabinet must extend outward for
at least 10" and there should be no obstacles,
such as a fence or wall, within 20" from the back of
the cabinet because it will prevent heat radiation of
the condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
4. Install the unit a little slanted so the back is slightly
lower than the front (about 1/2"). This will force
condensed water to the outside.
5. Install the unit with the bottom about 30"
¡›
60"
above the floor level.
3-2. CHECK OF INSTALLATION
The setting conditions must be checked prior to
initial starting.
The undermentioned items are especially
inportant checking points when the installation is
finished.
1. Grounding wire (Green of Green Yellow) is
provided in the power cord. The green wire must
be grounded.
2. Connect to a single-outlet 15AMP circuit.
3. To avoid vibration or noise, make sure the air
conditioner is installed securely.
4. Avoid placing furniture or dreperies in front of the
air inlet and outlet.
3.3 HOW TO USE DRAIN
(When using drain tube)
The air conditioner must be installed level or titled
slightly to the outside for proper water drainage.
On exceptionally not and humid days the air
conditioner may drain condensation through
overflow. If the air donditioner is used in hot and
a high humidity zone, dxchange the 
¤
HOLE
RUBBER for the 
¤Ł
DRAIN PIPE. (See figure 25,
figure 26)
— 12 —
All side louvers of the cabinet must remain
exposed to the outside of the structure.
CAUTION
AWNING
FENCE
HEAT
RADIATION
COOLED AIR
ABOUT
Over 20"
1
/
4
"
30"-60"
Figure 24
BOTTOM
BASE PAN
DRAIN PIPE
BOTTOM
HOLE RUBBER
BASE PAN
Figure 25
Figure 26
1
2
— 13 —
3.4 HOW TO INSTALL
3.4.1 WHEN USING GASKET
2
2
1
3
C
E
D
F
A
B
RIGHT SIDE
J
HORIZNTAL  
LINE
Figure 28
Figure 27
1. WINDOW (WIDTH, HEIGHT-B)
2. GASKET
3. WALL
A
B
C
D
E
F
G
487mm
324mm
30mm
0
¡›
25mm
OVER 240mm
5
¡›
10mm
-5
¡›
5mm
(19 
3
/
16"
)
(12 
3
/
4"
)
(1 
1
/
16"
)
(0
¡›
1")
(9 
15
/
32"
)
(
3
/
16"
¡›
3
/
8"
)
(-
3
/
16"
¡›
3
/
16"
)
4. TROUBLE SHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS (unit : mm)
348
312
472
OPERATION
THERMOSTAT
HIGH
HIGH
LOW
LOW
Page of 24
Display

LG LW-A0560CL Service Manual ▷ Download

  • DOWNLOAD LG LW-A0560CL Service Manual ↓ Size: 578.81 KB | Pages: 24 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LW-A0560CL in PDF for free, which will help you to disassemble, recover, fix and repair LG LW-A0560CL Air Conditioner. Information contained in LG LW-A0560CL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.