LG LT-B3680HL Service Manual ▷ View online
MEMO
–47–
P/No.: 3828A30021S
Dimensions
Indoor Unit
910
910
790
965
320
298
–6–
Outdoor Unit
Refrigeration Cycle Diagram
• COOLING ONLY
(
Rated performance for refrigerant line length of: 5m)
For installation over rated distance, 70g of refrigerant should be added for each meter.
ex) When installed at a distance of 15m, 700g of refrigerant should be added.
(15-5) x 70g = 700g
Pipe size(Diameter: ø)
Piping length(m)
Elevation(m)
MODEL
Gas
Liquid
Rated
Max.
Rated
Max.
COOLING ONLY
3/4"
3/8"
5
25
5
20
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGER
(EVAPORATOR)
EXCHANGER
(EVAPORATOR)
HEAT
EXCHANGER
(CONDENSER)
EXCHANGER
(CONDENSER)
COMPRESSOR
GAS SIDE
LIQUID SIDE
CAPILLARY TUBE
–7–
Click on the first or last page to see other LT-B3680HL service manuals if exist.