¡Æ
Cooling Mode with the Sleep Mode
ƒU
The setting temperature will be raised by 1
¡
30minutes  later and by 2
¡
1 hour later.
ƒU
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
¡Æ
Heating Mode with the Sleep Mode. 
ƒU
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
13
Intake Air temp.                   
COMP. ON
(SET TEMP.+0.5
¡
COMP. OFF
(SET TEMP. -0.5
¡
)
Morethan
More than
3 minutes
3 minutes
INDOOR FAN
Low
Low
Low
Low
Low
COMPRESSOR
ON
OFF
ON 
OFF
ON
Delay 3 minutes
30 minutes
30 minutes
1
¡
1
¡
Setting Temp. +3
¡
(Compressor OFF) 
Setting Temp.
(Compressor ON)
Indoor Fan
Med.
Med.
Med.
Med.
Med.
Med.
Compressor
ON
OFF
ON
OFF
ON
OFF
¢”
¢”
¢”
¢”
5. Auto Operation 
ƒU
The operation procedure is as following.
ƒN
If initial mode is decided, that mode is continued without the room temperature changing.
ƒ
ƒU
U
Auto Operation for Cooling.
14
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed
are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode
Heating
Soft Dry 
Cooling
Operation Condition 
Intake-air Temperature
Setting temperature
Fan speed 
Air Direction Control
Over 26°C
25°C
Over 24°C~below 26°C
Intake air -1.0°C
Over 22°C~below 24°C
Intake air -0.5°C
Over 20°C~below 22°C Intake air temperature
below 20°C
20°C
Over 20°C~below 30°C
Fuzzy control
below 20°C
20°C
Over 30°C
30°C
below   21
¡
below   
24
¡
~
Over   24
¡
Over   
21
¡
When Auto Operation
initial start
When Switch to 
Auto Operation
Controlled
by Fuzzy logic
1/f rhythm
Intake-Air temp
Setting Temp. +0.5°C
(Compressor OFF) 
Setting Temp.-0.5°C
(Compressor ON)
Indoor Fan
Compressor
ON
OFF
ON
OFF
Fuzzy Speed
¢”
¢”
ƒ
ƒU
U
Auto Operation for Soft Dry.
The Setting temperature will be set to the same that of the current intake-air temperature.
- Compressor ON temperature; Setting temperature +1°C
- Compressor OFF temperature; Setting temperature -0.5°C
ƒ
ƒU
U
Auto Operation for Heating.
15
Intake Air temp.
below 20°C 
over 20°C~below 21°C
Setting temp.
20°C 
Intake air Temperature +0.5°C 
21°C
20°C
20°C
Intake-Air temp.
Setting temp.
20.5°C
21°C
6. Natural Wind by CHAOS logic 
There are common rules in the irregular changes amid the breeze of highlands and valleys, the sound of
streams, the songs of birds in the forest and brain waves of relaxation.
Mmm... the breath-taking and touchy feeling of wind from the deep mountains and dark valleys.
Through analysis in its chaos simulator, Goldstar has successfully created such a feeling of freshness and
serenity by analyzing the frequency of natural wind.
Generally natural wind has the following character (frequency-Magnitude), for example dark vally, sea, moun-
tain wind.
So as to make a similar Natural wind function, Indoor fan speed is shifted to high from low or reversely in
according to the CHAOS logic.
16
Magnitude
frequency(Hz)
natural wind function
Page of 68
Display

Click on the first or last page to see other LS-S1260HL service manuals if exist.