Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp. 
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, CHAOS
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
OUTDOOR--- Lights up in compressor operation (for Cooling Model)
--- The function illustrates its dynamic mode 
by using a multiple lighting system.
(                                                          )
--- Linghts up in Telephone Control operation.
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed. 
• The louver can be set at the desired position or swing 
up and down automatically. 
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
• The function will be operated while in any
operation mode with selecting the function.
• The function is to be stopped while it is
operating with selecting the function.
• Both the indoor and outdoor fan  stops dur-
ing defrosting.
• The indoor fan stops until the 
evaporator pipe temperature will be reached
at 28°C.
• Calling from outside, you can start the air
conditioner to keep the room comfortable.
Even though you went out with the air condi-
tioner on, you can turn it off using the phone
outside.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
PLASMA
-4-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
PLASMA
Telephone Control Operation
-5-
Telephone Control Operation
Turn ON
1. Dial the number which is connected with the air conditioner.
2. After ringing 5 times.
3. You can hear the "Beep" sound (if the air conditioner is off), then press "0" "0" "7" "8"  accordingly.
4. With the sound "Beep, Beep" the air conditioner starts on.
5. Hang up the phone.
Turn OFF
1. Dial the number which is connected with the air conditioner.
2. After ringing 5 times.
3. You can hear the "Beep Beep" sound (if the air conditioner is on), then press "0" "0" "7" "9" accordingly.
4. With the sound "Beep---" the air conditioner is turned off.
5. Hang up the phone.
Telephone Control Operation(When using along with ARS telephone)
Turn ON
1. Dial the number which is connected with the air conditioner.
2. OGM guide is provided after signal sound rings four times and then "Beep"(sounds from telephone itself)
sounds so that outside recording can be done. 
3. Slowly press password "0"   "0"   "7"  and  "8" in order.
4. With the sound "Beep, Beep" the air conditioner starts on.
5. Hang up the phone.
Turn OFF
1. Dial the number which is connected with the air conditioner.
2. OGM guide is provided after signal sound rings four times and then "Beep"(sounds from telephone itself)
sounds so that outside recording can be done. 
3. Slowly press password "0"   "0"   "7"  and  "9" in order.
4. With the sound "Beep---" the air conditioner is turned off.
5. Hang up the phone. 