DOWNLOAD LG LS-R126ABG / LS-R126ABL / LS-R126AHG_AEL / LS-R126BBG_RBG / LS-R126CBG_FBG / LS-R126CEL_EEL / S12LHP Service Manual ↓ Size: 4.79 MB | Pages: 104 in PDF or view online for FREE

Model
LS-R126ABG LS-R126ABL LS-R126AHG_AEL LS-R126BBG_RBG LS-R126CBG_FBG LS-R126CEL_EEL S12LHP
Pages
104
Size
4.79 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-r126abg-ls-r126abl-ls-r126ahg-ael-ls-r126bbg-rb.zip
Date

LG LS-R126ABG / LS-R126ABL / LS-R126AHG_AEL / LS-R126BBG_RBG / LS-R126CBG_FBG / LS-R126CEL_EEL / S12LHP Service Manual ▷ View online

Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, CHAOS, JET COOL
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
OUTDOOR--- Lights up in compressor operation (for Cooling Model)
--- The function illustrates its dynamic mode
by using a multiple lighting system.
(
)
--- Linghts up in Telephone Control operation.
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed.
• The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
• The function will be operated while in any
operation mode with selecting the function.
• The function is to be stopped while it is
operating with selecting the function.
• Both the indoor and outdoor fan stops dur-
ing defrosting.
• The indoor fan stops until the
evaporator pipe temperature will be reached
at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
PLASMA
-4-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
PLASMA
-5-
Healthy Dehumidification Operation Mode.(       )
Remote Control
Operation ON/OFF
Reset
Operation Mode Selection
Temperature Setting
Timer Selection
Timer Setting
JET COOL
Timer Cancel
Sleep Operation
Airflow Direction Control
(Cooling 
model only)
(Heating 
model only)
TEMPERATURE
LOW
HIGH
Cooling Operation Mode.(       )
Heating Operation Mode.(       )
Auto Operation Mode.(       )
Fan Operation Mode
Horizontal Airflow Direction Control Button(Optional)
Room, Temperature Display
Setting the Time or Timer
PLASMA(Optional)
ON
OFF
SET
PLASMA
CANCEL
Fan Speed Selection
(Low)
(Med)
(High)
(CHAOS)
: (High:39°C
Low:11°C)
: OFF, ON, OFF
ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Cooling
Down to 18°C
Up to 30°C
Heating
Down to 16°C
Up to 30°C
-6-
Product References
Model Name
Item
Unit
Cooling Capacity
Btu/h
12,000
Heating Capacity
13,000
Moisture Removal
l
/h
1.18
Power Source
Ø, V, Hz
1Ø, 220-240V, 50Hz
8.3
26
39
48
Cooling
W
1,260
Heating
1,230
Running
Cooling
A
5.8
Current
Heating
5.5
E.E.R.
Cooling
Btu/hW
9.5
C.O.P
Heating
3.09
14.4
25.5
900 x 285 x 156
770 x 540 x 245
8
35
Refrigerant
g
860(R22)
Airflow Direction Control (Up & Down)
O
Remocon Type
L.C.D Wireless
inch(mm)
1/4" (6.35)
1/2" (12.7)
Sleeping Operation
O
Drain Hose
O
Connecting Cable
1.0mm
2
Power Cord
1.0mm
2
Air Circulation
Noise Level
Input
m
3
/min
dB (A)±3
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Service Valve
Motor Output
Dimensions
(W x H x D)
Net. Weight
W
mm
kg
LS-R126_Series
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving
performance
-7-
Installation plate
D
H
W
MODEL
DIM
Unit
W
mm
900
H
mm
285
D
mm
156
12K Btu Series
Dimensions
(1) Indoor Unit
Page of 104