DOWNLOAD LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Service Manual ↓ Size: 7.78 MB | Pages: 127 in PDF or view online for FREE

Model
LS-Q076ABL_BBG_BEL_ABG LS-Q096ABL_BBG_BEL_AEL LS-Q096ACG_ADG_ADL_BDL LS-Q096AHG_ABG_ABM LS-Q096BAG_BDG LS-Q096ACL_AAG LS-Q082BAG_BAM LS-Q082AAL_ACG_ACL_ACM
Pages
127
Size
7.78 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-q076abl-bbg-bel-abg-ls-q096abl-bbg-bel-ael-ls-q.zip
Date

LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Service Manual ▷ View online

Wiring Diagram
-11-
(1) Indoor Unit 
(2) Outdoor Unit 
1. LS-Q076ABL, LS-Q076BBG, LS-Q076BEL
LS-Q096ABL, LS-Q096ABG, LS-Q066AHG
LS-Q096AEL, LS-Q096BBG, LS-Q096ABM
2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG
LS-Q096ADL, LS-Q096ADG, LS-Q096BAG
LS-Q096BAG, LS-Q096BDG, LS-Q096BDL
LS-Q082BAM
3. LS-Q082BAG, LS-Q096ACL, LS-Q082AAL
LS-Q082ACG, LS-Q082ACL, LS-Q082ACM
1. LS-Q076ABL, LS-Q076ABG, LS-Q076BBG
LS-Q076BEL
2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG
LS-Q096ADL, LS-Q096ADG, LS-Q096ACL
LS-Q096BAG, LS-Q096BDG, LS-Q096BDL
LS-Q082BAG, LS-Q096ABM, LS-Q082AAL
LS-Q082BAM, LS-Q082ACG, LS-Q082ACL
LS-Q082ACM
3. LS-Q096ABL, LS-Q096AEL, LS-Q096ABG
LS-Q096AHG, LS-Q096BBG, LS-Q096BEL
LS-Q096ABM
PO
WER
BR
(
BK/Plained
)
GN/YL
BR
BL
GN/YL
BL
(
WH/Rib
bed
)
1(L)
2(N)
MOTOR
CN-MOTOR
CN-TAB1
CN-A
C
/DC
CN-A
C
/DC
CN-TH
THERMISTOR
STEP
MOTOR
STEP
MOTOR
H.V.
ASM
RD AIR
CLEAN
(
PLASMA
)
SAFETY  S/W1
SAFETY  S/W2
BK
BK
BK
BK
BK
CN-U/D
CN-L/R
CN-DISP
DISPLAY PWB ASM
INDOOR WIRING DIAGRAM
3854A20142B
SW(FORCE)
T/BLOCK
TO OUTDOOR UNIT
TRIAC
AC PWB ASM
DC PWB ASM
OR
BK
BR
4
RY-COMP
FUSE 
250V T2A
3
YL
SH-CAPA
MOTOR
OR
RD
BK
BK
BK
BK
BK
BK
BK
BK
BK
PO
WER
BR(BK/Plained)
BL(WH/Rib
b
ed)
BK
YL
SH-CAPA
T/BOARD
T-BLOCK
CN-MOTOR
THERMISTOR
STEP
MOTOR
CN-A
CDC1
CN-A
CDC2
CN-TH
CN-U/D
CN-L/R
CN-HVB
CN-12V
CN-DISP
DISPLAY PWB ASM.
P/No : 3854A20238J
CN-CONT
TRIAC
AC PWB ASM.
DC PWB ASM.
CN-TAB
RY-COMP
TO OUTDOOR UNIT
INDOOR WIRING DIAGRAM
4
3
1(L)
BR
BR
BL
GN/YL
2(N)
FUSE
250V T2A
STEP
MOTOR
H.V.
ASM.
S/W1
S/W2
AIR
CLEAN
(PLASMA)
GN/YL
GN/YL
MOTOR
OR
RD
BK
BK
BK
BK
BK
BK
BK
BK
BK
PO
WER
GN/YL
GN/YL
BR(BK/Plained)
BL(WH/Rib
bed)
BK
YL
SH-CAPA
T/BOARD
T-BLOCK
RY-4WAY
RY-FAN
CN-MOTOR
THERMISTOR
STEP
MOTOR
CN-A
CDC1
CN-A
CDC2
CN-TH
CN-U/D
CN-L/R
CN-HVB
CN-12V
CN-DISP
DISPLAY PWB ASM.
P/No : 3854A20238H
CN-CONT
TRIAC
AC PWB ASM.
DC PWB ASM.
CN-TAB
RY-COMP
TO OUTDOOR UNIT
INDOOR WIRING DIAGRAM
4
3
1(L)
BR
BR
BL
BK
RD
GN/YL
2(N)
3
4
FUSE
250V T2A
STEP
MOTOR
H.V.
ASM.
S/W1
S/W2
AIR
CLEAN
(PLASMA)
TO INDOOR UNIT
BLACK
GRAY
PILLAR
TERMINAL
BR
BR
YL
BK
OLP
1
2
3
COMP
RD
BK
BL
BL
FAN
MOTOR
REVERSING
VALVE
GN/YL
RD
BL
CAPACITOR
H
C
F
R
C
S
BR
BL
BK
RD
GN/YL
BR
BL
BK
RD
GN/YL
1
(
L
)  
2
(
N
)
3
4
3854AR2262E
OUTDOOR  WIRING  DIAGRAM
TO INDOOR UNIT
BLACK
PILLAR
TERMINAL
BR
BR(YL)
OLP
1
COMP
RD
BL
BL
YL
FAN
MOTOR
GN/YL
RD
BL
CAPACITOR
H
C
F
R
C
S
BR
BL GN/YL
BR
BL GN/YL
1
(
L
)  
2
(
N
)
3854AR2262F
OUTDOOR  WIRING  DIAGRAM
COMP
C S R
FAN
MOTOR
OLP
BR RD BL
BR
BL
BK(RD)
YL
GN/YL
BR
BL
BK
RD
GN/YL
BL
BL
REVERSING
VALVE
RD BL YL
GN/YL
BK(RD)
CAPACITOR
RD
BL
YL
TO  INDOOR  UNIT 
OUTDOOR  WIRING  DIAGRAM
3854A30077D
TERMINAL
BLOCK
H
C
F
PTC
1(L) 2(N)
3
4
Operation Details
1. MAIN UNIT FUNCTION 
• DISPLAY
1) C/O Model 
Operation Indicator
• ON while in appliance operation, OFF while in appliance pause.
• Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)
Sleep Timer Indicator
• ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.
Timer Indicator
• ON while in timer mode (on/off), OFF when timer mode is completed or canceled.
Comp. Running Incidator
• While in appliance operation, ON while in outdoor unit compressor running, OFF while in compressor off.
2) H/P Model
Operation Indicator
• ON while in appliance operation, OFF while in appliance pause.
• Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)
Sleep Timer Indicator
• ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.
Timer Indicator
• ON while in timer mode (on/off), OFF when timer mode is completed or canceled.
Defrost Indicator
• OFF except when hot start during heating mode operation or while in defrost control.
Cooling Mode Operation
• When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan
stop.
• When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp 
➲ 
Setting Temp+0.5°C
Compressor OFF Temp
Setting Temp-0.5°C
• While in compressor running, operating with the airflow speed set by the remote control. While in compressor
not running, operating with the low airflow speed regardless of the setting.
Healthy Dehumidification Mode
• When the dehumidification operation input by the remote control is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C 
Intake Air Temp     
➲ 
25°C
24°C 
Intake Intake Air Temp<26°C
➲ 
Intake Air Temp-1°C
18°C 
Intake Intake Air Temp<24°C
➲ 
Intake Air Temp-0.5°C
Intake Air Temp<18°C
➲ 
18°C
-12-
• While in compressor off, the indoor fan repeats low airflow speed and pause.
• While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidifica-
tion operation and 4-min compressor off repeat.
Compressor ON Temp.
Setting Temp+0.5°C
Compressor OFF Temp.
Setting Temp-0.5°C
• In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.
Heating Mode Operation
• When the intake air temp reaches +3°…above the setting temp, the compressor is turned off.  When below
the setting temp, the compressor is turned on.
Compressor ON Temp.
Setting Temp.
Compressor OFF Temp.
Setting Temp.+3°C 
• While in compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C, when above 28°C , it
operates with the low or setting airflow speed. When the indoor pipe temp is between 20°C and 28°C, it oper-
ates with Super-Low(while in sleep mode, with the medium airflow speed).
• While in compressor off, the indoor fan is off when the indoor pipe temp is below 33°C, when above 35°C , it
operates with the low airflow speed.
• If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the
outdoor fan is turned on/off according to the indoor pipe temp.
• While in defrost control, both of the indoor and outdoor fans are turned off.
Defrost Control
• While in heating mode operation in order to protect the evaporator pipe of the outdoor unit from freezing,
reversed to cooling cycle to defrost the evaporator pipe of the outdoor unit.
• After 40 min heating mode operation, at 4 min interval, whether to carry out defrost control or not and the time
of defrost control are determined according to the following conditions.
1) While in heating mode operation, the maximum of the indoor pipe temperature is measured and it is com-
pared with the present indoor pipe temperature to get the difference of the indoor pipe temperatures (=the
maximum temperature of indoor pipe ? the present temperature of indoor pipe), according to which, whether
to carry out defrost control or not is determined.
2) According to the need of defrost control shown above and the elapsed time of heating mode operation at that
moment, the defrost control time is determined.
3) When the determined time of defrost control is below 7 min, heating mode operation continues without carry-
ing out defrost control. According to the procedure stated above, the determination is made again. When the
defrost control time is 7 min or longer, defrost control is then carried out.
• While in defrost control, the minimum temp of the indoor pipe is measured and it is compared with the present
temp of the indoor pipe to get the difference of the indoor pipe temperatures (=the present temperature of the
indoor pipe ? the minimum temperature of the indoor pipe).  When the difference is 5°C or higher, defrost con-
trol is completed and heating mode operation is carried out.
• While in defrost control, if the defrost time determined before the start of defrost control is completed, defrost
control stops and heating mode operation is carried out regardless of  the above condition.
• When the indoor pipe temp is 42°C or above, defrost control is not carried out even if the condition is one of
the defrost conditions above.
• While in defrost control, the compressor is on and the indoor fan, the outdoor fan, and the 4 way valve are off.
-13-
-14-
■ 
Fuzzy Operation (C/O Model)
• According to the temperature set by Fuzzy rule, when the intake air temp is 0.5°C or more below the setting
temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is turned on.
Compressor ON Temp   
Setting Temp + 0.5°C
Compressor OFF Temp 
Setting Temp + 0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C 
Intake Air Temp      
25°C
24°C 
Intake Air Temp < 26°C 
Intake Air Temp + 1°C
22°C 
Intake Air Temp < 24°C 
Intake Air Temp + 0.5°C
18°C 
Intake Air Temp < 22°C 
Intake Air Temp
Intake Air Temp<18°C
➲ 
18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule. 
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the 
temperature.
Fuzzy Operation (H/P Model)
• When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
• When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor fan is operated for 15 seconds.  Then an operation mode is selected according to the intake air
temp at that moment as follows.
24°C 
Inatake Air Temp   
Fuzzy Operation for Cooling
21°C 
Inatake Air Temp<24°C
Fuzzy Operation for Dehumidification
Inatake Air Temp<21°C 
Fuzzy Operation for Heating
• If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off.  When 0.5°C or more above the setting temp, the compressor
is turned on.
Compressor ON Temp  
Setting Temp +0.5°C
Compressor OFF Temp 
Setting Temp + 0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C
Intake Air Temp      
25°C
24°C
Intake Air Temp<26°C 
Intake Air Temp + 1°C
22°C
Intake Air Temp<24°C 
Intake Air Temp + 0.5°C
18°C
Intake Air Temp<22°C 
Intake Air Temp
Intake Air Temp<18°C       
18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the tem-
perature.
Page of 127
Display

LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Service Manual ▷ Download

  • DOWNLOAD LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Service Manual ↓ Size: 7.78 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Air Conditioner. Information contained in LG LS-Q076ABL_BBG_BEL_ABG / LS-Q096ABL_BBG_BEL_AEL / LS-Q096ACG_ADG_ADL_BDL / LS-Q096AHG_ABG_ABM / LS-Q096BAG_BDG / LS-Q096ACL_AAG / LS-Q082BAG_BAM / LS-Q082AAL_ACG_ACL_ACM Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.