-5-
Cooling Mode
Lights up during Cooling operation. (Outline)
Auto Operation Mode
Lights up during Auto operation. (Outline)
Healthy Dehumidification
Lights up during Healthy Dehumidification operation. (Outline)
Mode
Heating Mode
Lights up during Heating operation.
(Heat Pump model only) (Outline)
Defrost Mode
Lights up during Defrost control or
Hot Start in Heating operation. (Outline)
Air circulation Mode
Lights up during Air Circulation operation. (Outline)
Sleep Mode
Lights up during Sleep Mode operation.
Timer Mode
Lights up during Timer operation.
Auto Cleaning Mode
Lights up during Auto Cleaning reservation.
Jet Cool Mode
Lights up during Jet Cool Operation.
Plasma
Lights up during Plasma operation.
Fan Speed (Low)
Lights up when Fan speed is low.
Fan Speed (Medium)    Lights up when Fan speed is Medium.
Fan Speed (High)    Lights up when Fan speed is High.
Fan Speed (Chaos)    Lights up when Fan speed is Chaos.
Desire temperature  For cooling,dehumidification,heating modes it display Desired temperature
indicator
• Cooling
: 18~30
°
C
• AI : Auto Operation
• Dehumidification : 18~30
°
C
• Po : Jet Cool
• Heating
: 16~30
°
C
• Lo : Test Mode 
 
• C1 : Indoor pipe sensor error
Desire temperature Icon
Indoor temperature Icon
Signal Receptor
Each Icon turns on when the unit is operated, then the only Icon outline to be operated is bright.
-6-
Healthy Dehumidification Operation Mode.(       )
Remote Control
Operation ON/OFF
Reset
Operation Mode Selection
Temperature Setting
Timer Selection
Timer Setting
JET COOL
Timer Cancel
Sleep Operation
Airflow Direction Control
(Cooling 
model only)
(Heating 
model only)
TEMPERATURE
LOW
HIGH
Cooling Operation Mode.(       )
Heating Operation Mode.(       )
Auto Operation Mode.(       )
Air Circulation
Horizontal Airflow Direction Control Button(Optional)
Room, Temperature Checking
Setting the Time or Timer
PLASMA(Optional)
Fan Speed Selection
(Low)
(Med)
(High)
ON
OFF
CANCEL
SET
2nd F
AUTO CLEAN
LED LUMINOSITY
AUTO CLEAN
: (High:39°C
Low:11°C)
: OFF, ON, OFF                ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7,  Off Timer
: Fan Operates without cooling or heating.
Cooling
Down to 18°C
Up to 30°C
Heating
Down to 16°C
Up to 30°C
-7-
Product References
Model Name
Item                            Unit
Cooling Capacity
Btu/h
Heating Capacity
Moisture Removal
l
/h
Power Source
Ø, V, Hz
Cooling
W
Heating
Running Cooling
A
Current
Heating
E.E.R.
Cooling
Btu/hW
C.O.P
Heating
Refrigerant g
Airflow Direction Control (Up & Down)
Remocon Type
inch(mm)
Sleeping Operation
Drain Hose
Connecting Cable
Power Cord
Air Circulation
Noise Level
Input
m
3
/min
dB (A)±3 
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Service Valve
Motor Output
Dimensions
(W x H x D)
Net. Weight
W
mm
kg
LS-H096Z_Series
LS-H076Z_Series
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving 
performance
9,000
7,000
9,300
7,300
1.0
1.0
1Ø, 220-240V, 50Hz
1Ø, 220-240V, 50Hz
6.8
5.7
26
20
35
32
48
48
940
700
850
628
4.2
3.2
3.8
2.9
9.57
10
3.2
3.4
7.8
4.7
27
18
900 x 272 x 135
900 x 272 x 135
770 x 540 x 245
575 x 525 x 260
8.14
8.14
33
23
R-22, 920
R-22, 680
O
O
L.C.D Wireless
L.C.D Wireless
1/4" (6.35)
1/4" (6.35)
3/8"(9.52)
3/8"(9.52)
O
O
O
O
0.75mm
2
0.75mm
2
0.75mm
2
0.75mm
2
-8-
Installation plate
D
H
W
MODEL 
DIM         Unit
W
mm
900
H
mm
273
D
mm
135
7K, 9K Btu Series
Dimensions
(1) Indoor Unit 
Page of 62
Display

Click on the first or last page to see other LS-H076ZBC0 service manuals if exist.