- 5 -
Product Specifications 
Cooling Capacity
BTU/h(kcal/h)
W
Heating Capacity
BTU/h(kcal/h)
W
Moisture Removal
l
/h
Power Source
Ø, V, Hz
Air Circulation
m
3
/min
Noise Level
dB(A)
Input
W
Runnig Current
A
Starting Current
A
E.E.R.
BTU/h-W
C.O.P
W/W
Motor Output
W
mm
Net. Weight
kg
Refrigerant(R-22)
g
Airflow Direction Control (Up & Down)
Airflow Direction Control (Right & Left)
Negative lon
Air Purifying Filter
Deicer
Hot Start
Chaos Wind or Auto Wind
Micom Dry
Timer
Self Diagnosis
Remocon type
Service valve
Sleeping Operation
Drain Hose
Connecting Cable
Power Cord
18,000(4,536)
5,274
-
-
2.5
1Ø, 220-240V, 50Hz
12
42
43±3
53±3
1,860
-
8.8
-
52
-
9.7
-
20
62
1,080 x 290 x 183
870 x 655 x 320
12
57
1,270
YES
NO
NO
NO(OPTION)
NO
NO
YES
YES
24hr ON/OFF
YES
L.C.D Wireless
1/4"(6.35)
1/2"(12.7)
YES
YES
1.5(2.5)mm
2
1.5(2.5)mm
2
18,000(4,536)
5,274
20,000(5,040)
5,860
2.5
1Ø, 220-240V, 50Hz
12
42
43±3
53±3
1,860
2,060
8.5
9.4
53
53
9.7
2.84
20
62
1,080 x 290 x 183
870 x 655 x 320
12
59
1,300
YES
NO
NO
NO(OPTION)
NO
NO
YES
YES
24hr ON/OFF
YES
L.C.D Wireless
1/4"(6.35)
1/2"(12.7)
YES
YES
1.5(2.5)mm
2
1.5(2.5)mm
2
24,000(6,048)
7,032
-
-
3.1
1Ø, 220V, 60Hz
15
42
48±2
55±3
2,300
-
12.2
-
54
-
10.4
-
Max. 45(BLDC MOTOR)
62
1,080 x 290 x 183
870 x 655 x 320
12
59
1,650
YES
NO
NO
NO
NO
NO
YES
YES
24hr ON/OFF
YES
L.C.D Wireless
1/4"(6.35)
5/8"(15.88)
YES
YES
0.75mm
2
1.5(2.5)mm
2
Model Name
Unit
Indoor
Outdoor
Indoor
Outdoor
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Dimensions
(W x H x D)
Item
LS-D1864CL/CM/CD
LS-D1865CL/CM/CD
LS-D1864/HL/HM/HD
LS-D1865HL/HM/HD
LS-D2424CL/CM
Trouble analysis
1. Check temperature difference between intake and discharge air and operating current.
• All amount of refrigerant leaked out. 
• Check refrigeration cycle.
• Refrigerant leakage
• Clog of refrigeration cycle
• Defective compressor
• Excessive amount of refrigerant
• Normal
Notice:
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower tem-
perature difference is larger.
2. Check temperature and pressure of refrigeration cycle.
Notice:
1. The suction pressure is usually 4.5~6.0 kg/cm
2
G at normal condition.
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.
- 50 -
Cycle Troubleshooting Guide
Temp. difference 
: approx. 0°C
Current
: less than 80% of
rated current
Temp. difference 
: approx. 8°C
Current
: less than 80% of
rated current
Temp. difference 
: less than 8°C
Current
: over the rated
current
Temp. difference 
: over 8°C
Temp. Difference 
Operating Current
Suction pressure
Temperature
(Compared with
(Compared with
Cause of Trouble
Description
the normal value)
the normal value)
High
Defective compressor
Current is low.
Defective 4-way reverse valve
Normal
Excessive amount of 
High pressure does not quickly 
refrigerant
rise at the beginning of operation.
Insufficient amount of
Current is low.
Lower
Higher
refrigerant(Leakage)
Clogging
Current is low.
Higher
- 51 -
Possible Trouble 1
: The unit does not operate.
Electronic Parts Troubleshooting Guide
<18K models>
WARNING: 1.When servicing the unit, remove the power cord of outdoor unit.
2.The FAN MOTOR of outdoor unit operates intermittently for the reliability of the unit during operation.
- 52 -
Possible Trouble 2
: Fan does not operate.