LG LS-A0560CL Service Manual ▷ View online

Functions
ƒU
Room temperature sensor. (THERMISTOR)
ƒU
Maintains the room temperature in accordance with the Setting Temp. 
ƒU
Indoor fan is delayed for 3 sec at the starting.
ƒU
Restarting is inhibited for approx. 3 minutes.
ƒU
High, Low
--- Lights up during cooling operation
--- Lights up during soft dry operation
--- Lights up during timer operation
ƒU
Intermittent operation of fan at low speed.
ƒU
The unit will be stopped after 1 hour.
ƒU
Standard condition operation.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
Forced Operation Control
Timer Control
ƒ¡
3
ƒ¡
ƒ¡
4
ƒ¡
Remote Controller
Operation ON/OFF
Soft Dry Selection
Fan Speed Selection
Temperature Setting
1hr Timer Selection
: ON/OFF
: SOFT DRY/COOLING
: HIGH/LOW
Up to 30
¡
Down to 20
¡
Installation 
1) Selection of the best location 
1.  Indoor unit. 
• There should not be any heat source or steam
near the unit. 
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good. 
• A place where drainage can be easily obtained.
• A Place where noise prevention is taken into
consideration.
•  Do not install the unit near the door way.
•  Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles. 
2.  Outdoor unit.
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not restrict-
ed. 
•  There should not be any animals or plants which
could be affected by hot air discharged. 
• Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles. 
3. Piping length and the elevation.
More than 5cm
More than eye-level
More than
  5cm
More than
         5cm
More than 10cm
More than 10cm
More than 70cm
A
B
Indoor unit
Outdoor unit
1. Installation of indoor, Outdoor unit 
ƒ¡
11
ƒ¡
Pipe Size
Max. piping
Max.
length
Elevation
GAS
LIQUID
A(m)
B(m)
3/8"
1/4"
7
1) Checking the Drainage
1. Remove the Grille from the cabinet.
• Set the up-and-down air direction louver to open
position (horizontally) by finger pressure.
• Remove the screw caps and the securing
screws.
• To remove the Grille, pull lower the left and right
side of the grille toward you (slightly tilted) and
lift it straight upward (Two tabs on the top inside
edge of the grille are clear of their slots). 
2. Check the drainage.
• Pour a glass of water on the evaporator.
• Ensure if water flows drain hose of indoor unit
without any leakage.
Pull on the right and the left side.
Screw
(both the left and the right side)
4. Checking the Drainage and Connecting the cable to Indoor unit
ƒ¡
20
ƒ¡
Page of 44
Display

LG LS-A0560CL Service Manual ▷ Download

  • DOWNLOAD LG LS-A0560CL Service Manual ↓ Size: 1.08 MB | Pages: 44 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-A0560CL in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-A0560CL Air Conditioner. Information contained in LG LS-A0560CL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.