– 65 –
8) No heater operation works
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Is the heating operating?
Is the Compressor 
operating?
Is the Heat S/W of Main
PCB "ON"?
Heat S/W "ON"
Replacement MICOM
Replacement ICO2M
Replacement RY-Heater
Is the DC 5V at 15 pin of
MICOM
Is the 
DC 12V at eack terminal? 
(RY-Heater COIL)
Is the
AC220V (AC 240 V) between
connector(HEATER) and CN-outunit Pin 1
of Main P.C.B
Check the heater wiring
Select the heating operation mode.
Compressor "ON"
– 52 –
Failures to Start
Check of circuit breaker
and fuse.
Check control switch.
Fan only fails to start
Improper wiring
Defect of fan motor
capacitor.
Irregular motor 
resistance 
 )
Irregular motor 
insulation 
 )
Replacement of fan motor.
Improper electric heater
Replacement of electric 
heater
Regular but fails to start.
Replacement of compressor
Electric heater is not energized
Loose terminal connection.
Improper wiring
Irregular motor resistance 
 )
Irregular motor insulation 
 )
Replacement of compressor
Drop of power voltage
Capacitor check
Replacement
Compressor only fails to
 start
Defect of compressor
capacitor
Check power source.
Check control switch
setting.
– 53 –
PACKAGE AIR CONDITIONER VOLTAGE LIMITS
9.1 No cooling and heating operation performed
1) Both the blower and the compressor do not work
NAME PLATE RATING
MINIMUM
MAXIMUM
380 V
342 V
418 V
220 V
198 V
242 V
380 - 415 V
342 V
456 V
2) Only blowers do not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Other parts than the unit
Magnetic switch for com-
pressor & fan motor 
Operating switch
Protection devices
Electric supply interrupted
Defective power wiring
Cut of power fuse
Too low voltage
Control point is on condi-
tion of "OFF" due to trou-
ble.
Troubled or defective
contactor
Opened the contact point
with trouble
Measure it with a tester in
case that the same
power source is supplied
to other equipment than
the unit, what and where
trouble can be discov-
ered by checking the
operation of other equip-
ment.
Measure it with a tester.
Make short-circuit, then
measure it with a tester. 
Check it with the eyes or
tester.
Check it with the eyes or
tester.
Repair a switch box and
is relative instrument.
Replacement of fuse
Request a power 
supplier to repair.
Check the power source.
Use a thick cable if nec-
essary.
Replace it if necessary.
Repair or replace it.
Discover the trouble
cause and push the rest
button.
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Air volume change over
switch
Capacitor
Troubled or defective 
contact point
Defected
Check it with the eyes or a
tester
Check it with a tester.
Repair or replace it.
Replace it.
– 54 –
3) Only outdoor fan does not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Motor
Electric Wiring
Over-heated
Layer short
Open wire on operation
Short circuited on 
operation
Check how it is insulated.
Check it with a tester.
Repair or replace it.
Rewiring or repair.
4) Only compressor does not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Magnetic switch for
compressor motor
Compressor motor
Compressor
High pressure switch
Electric circuit
Defective contact, 
magnetic coil troubled.
Troubled over-heated 
(layer short)
Troubled or over-heated 
(lock)
Troubled or defective 
contact or operating
Defective connection or
disconnection of the circuit
for compressor.
Check it with the eyes on
with a tester.
Check how it is insulated.
Groaned noise of motor
Check it with a tester.
Check it with a tester.
Repair or replace it.
Replace or repair the
compressor.
Repair or replace it.
Replace it if necessary.
Rewiring or push reset
button.
Page of 80