LG LM-3060HL Service Manual ▷ View online
3828AR3444W 2
Parts List
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
733010
149303
346811
131410
135501
359011
342800
354210
35211B
W6711
249951
235000
261704
W6640
268712
668711
268715
263230
352150
135311
140570
135313
135312
159901
159901-1
152302
135511
1
1H00843A
1
2
3H03651A
1
3
2H02441C
1
R
2H02441E
1
4
2H02440G
1
R
5
3H03652A
1
6
2H02426A
1
R
7
3H02821A
1
R
8
3H03711A
1
9
2H02449B
1
10
6711AR1172B
1
R
11
3A00375D
1
12
3A00375A
1
13
4781AR2061D
1
14
4780AR1013A
1
15
6171AQ2024C
1
R
16
4H03048F
1
R
17
6047AQ3014A
1
R
18
6047AQ2045B
1
R
19
6047AQ2047A
1
R
20
3Q35099A
1
R
21
3H03716A
1
R
22
2H01721E
1
23
1H00866E
1
24
3H02857A
1
25
3H03718B
1
26
3H03719B
1
27
1H00830K
1
28
1H00867M
1
R
29
3H03601A
1
R
30
3H03602B
1
R
31
3H03650B
3
32
2H02422A
2
R
33
3H03585T
1
34
4640AR3086A
(1)
PALTE ASSY, INSTALL
HOLDER, TUBING
MOTOR ASSY,
AC
CHASSIS ASSY
COVER, TUBING
FAN ASSY, CROSS FLOW
BEARING
EVAPORATOR ASSY
TUBING ASSY, TUBING
REMOTE CONTROLLER ASSY
SOCKET(MECH), FLARE
SOCKET(MECH), FLARE
CONTROLL BOX ASSY(IN)
CONTROL BOARD(IN)
TRANSFORMER POWER
TERMINAL BLOCK
PWB(PCB) ASSY, DISPLAY
PWB(PCB) ASSY, MAIN
PWB(PCB) ASSY, MAIN (AC)
THERMISTOR ASSY
CASE ASSY
HOSE ASSY, DRAIN
GRILLE ASSY, DISCHARGE (IN)
LOCKER ASSY
BRACKET ASSY
BRACKET ASSY
GRILLE ASSY, INLET
GRILLE ASSY, FRONT
VANE HORIZONTAL
VANE HORIZONTAL
CAP
FILTER(MECH), AIR
COVER ASSY, CONTROL (IN)
SCREEN FILM
2. Outdoor Unit
3828AR3444W 3
42
31
25
3
27
16
39
40
23
22
1
18
21
20
19
41
34
33
26
24
28
30
29
4
5
17
13
15
8
9
10
11
12
2
6
37
36
32
35
38
14
1
3A02084D
1
2
4H00525B
4
3
2A01233B
1
4
2A00957B
1
5
2A01232A
1
6
2A01032A
1
7
3A02035A
1
8
3H03569B
4
9
3H03569U
1
10
3H03569T
1
11
3H03569V
1
12
3H03569W
1
13
3A02028F
1
14
3Q35099D
1
15
4849AR2071A
1
16
2A01236B
1
17
2A01039B
1
18
4908AR1016A
1
19
2A90028F
3
Ø6.35
20
2A00393G
2
Ø9.52
21
2H01890G
1
Ø12.7
22
2A01043A
1
23
2A01035E
1
24
2H02113F
1
25
4A01489A
4
26
1A00195A
1
27
1A00202Z
1
28
2A01041C
1
29
2A00914A
1
30
2A00913A
1
31
3A01934A
1
32
2A00929A
1
33
2A00986F
1
34
2A00987A
1
35
3H00390A
2
36
3Q71207B
1
37
3A01911B
1
38
6047AQ2074A
1
39
1A00208P
1
40
3A02284B
1
41
3A02087D
1
42
3H03266A
1
3828AR3444W 4
Parts List
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
430410
554030
554030
554030
554170
552570
561410
561410-1
561410-2
561410-3
561410-4
561410-5
263230
548490
552113
552112
552203
552203-1
552203-2
447910
549610
346811
350140
559010
137213
437210
435311
349480
237200
W0CZZ
666000
W6640
261704
567480
435300
137213
435511
435512
BASE ASSY(OUT)
SCREW
CONDENSER ASSY
CONDENSER ASSY
CONDENSER ASSY
COMPRESSOR ASSY
MUFFLER
COIL ASSY, REVERSING VALVE
COIL ASSY, REVERSING VALVE
COIL ASSY, REVERSING VALVE
COIL ASSY, REVERSING VALVE
COIL ASSY, REVERSING VALVE
COIL ASSY, REVERSING VALVE
THERMISTOR ASSY
ACCUMULATOR ASSY(MECH)
TUBE ASSY, CONDENSER(OUT)
TUBE ASSY, CONDENSER(IN)
SUPPORTER VALVE
VALVE, SERVICE
VALVE, SERVICE
VALVE, SERVICE
BARRIER ASSY, OUTDOOR
MOUNT ASSY, MOTOR (OUTDOOR)
MOTOR ASSY, AC
ISOLATOR, MOTOR
FAN ASSY, PROPELLER
PANEL ASSY, SIDE
PANEL ASSY, FRONT(OUTDOOR)
GRILLE ASSY, DISCHARGE(OUT)
ORIFICE
BRACKET
PANEL CONTROL
CAPACITOR
SWITCH MAGNET
TERMINAL BLOCK
TRANSFORMER POWER
P.T.C
PWB(PCB) ASSY
GRILLE REAR
PANEL ASSY, SIDE
COVER ASSY, CONTROL(OUT)
COVER ASSY, TOP(OUT)
- 3 -
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation Indication Lamps (LED)
Soft dry Operation Mode
Sleep Mode Auto Control
Hot-start Control (Heating)
Auto Air Control
Airflow Direction Control
Deice (defrost) control (Heating)
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 se. at the starting.
• Restarting is inhibited for appros. 3 minutes.
• Low, Med, High, Auto
• The fan speed is low cooling mode for 10 minutes within the setting temperature which the compressor is operated
and not operated.
• The fan is switched to low speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The indoor fan stops until the evaporator piping temperature
will be reached 26°C (TEMP).
• The indoor fan operates 4minutes later even if the evapora-
tor piping temperature is not reached 26°C (TIME).
• Both the indoor and outdoor fna stops during deicing.
• Hot start after deice ends.
• Hot start after deice ends.
• The fan is switched automatically by the room
temperature.
• The louver can be set at the desired position
or swing up and down automatically.
(Red)
--- Lights up in Operation
(Green)
--- Lighyts up in Timer Mode
(Yellow)
--- Lights up in Sleep Mode
(Orange)
--- Lights up in Deice Mode (Heating Model only)