LG LM-1963H2L Service Manual ▷ View online
–4–
Remote Controller
Operation ON/OFF
Operation Mode Selection
Fan Speed Selection
Room Temperature Display
Temperature Setting
Setting the Time or Timer
(Cooling
model only)
(Heating
model only)
(Low)
(Med)
(High)
Cooling Operation Mode ( )
Heating Operation Mode ( )
Heating Operation Mode ( )
Soft Dry Operation Mode ( )
Fan Operation Mode
HI
MED
LO
Set
: High:39°C
¡Œ
LOW:11°C
: Fan Operates without cooling & heating
Cooling
Heating
Down to 18°C
Up to 30°C
,
Down to 16°C
Up to 30°C
,
–12–
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
• Ensure the spaces indicated by arrows from the
wall, ceiling, or other obstacles.
• The indoor unit must keep the maintenance
space.
2) Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not restrict-
ed.
heat radiation from the condenser is not restrict-
ed.
• There should not be any animals or plants which
could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
More than
10cm
More than 10cm
More than
70cm
,,
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Above 250
300 or less
100
or more
50 or
more
50 or
more
30 or less
,,,
yyy
zzz
{{{
|||
,
y
{
Floor
–21–
7. Installation of Decorative Panel
1. Temporarily fix two decorative panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount
10mm in length.)
The fixing screws (hexagon M5 screw) are included the decorative panel box.
The fixing screws (hexagon M5 screw) are included the decorative panel box.
2. Remove the air inlet grille from the decorative panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decorative panel key hole ( ) on the screws fixed in step above, and slide the panel so that
3. Hook the decorative panel key hole ( ) on the screws fixed in step above, and slide the panel so that
the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
5. Connect the louver motor connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
Decorative panel fixing screws
(hexagon M5 screws)
Temporality fitting at 2 places
(Tightening about 10mm)
(hexagon M5 screws)
Temporality fitting at 2 places
(Tightening about 10mm)
Decorative panel
Louver motor
connector
connector
Install the panel after
making sure that the
piping side of the unit body
matches the piping
indication of the decorative
panel
making sure that the
piping side of the unit body
matches the piping
indication of the decorative
panel
Control box
cover
cover
Louver motor connector
(In the control box)
(In the control box)
Air conditioner unit
Piping side
Inlet Grille
Decorative panel fixing screws
(Hexagon M5 screw)
(Hexagon M5 screw)
Key holes
The arrow ( ) should point
to the side where the pipes are.
to the side where the pipes are.
The decorative panel has its installation
direction.
direction.
Before installing the decorative panel,
always remove the paper template.
always remove the paper template.
¡
¡
ÿ
Method of connecting louver motor connector
• Louver motor housing consists in main PCB
• Open control cover, then connect louver motor connector to
• Open control cover, then connect louver motor connector to
louver motor housing in main PCB.
–22–
Install certainly the decorative panel.
Cool air leakage causes sweating.
¤
Water drops fall.
8. INDOOR UNIT DRAIN PIPING
• Drain piping must have down-slope (1/50 to
1/100): be sure not to provide up-and-down slope
to prevent reversal flow.
to prevent reversal flow.
• During drain piping connection, be careful not to
exert extra force on the drain port on the indoor
unit.
unit.
• The outside diameter of the drain connection on
the indoor unit is 32mm.
• Be sure to execute heat insulation on the drain
piping.
Air conditioner
unit
unit
Ceiling
board
Decorative panel
Decorative
panel
panel
Fit the insulator (this part) and
be careful for cool air leakage
be careful for cool air leakage
Good example
Air
Cool air leakage
(no good)
Bad example
Ceiling
board
Air conditioner unit
Maintenance
drain port
drain port
Upward
routing
not allowed
routing
not allowed
Pipe clamp
Indoor unit
CAUTION
Piping material: Polyvinyl chloride pipe VP-25
and pipe fittings
and pipe fittings
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
• Connect the main drain pipe to the exterior and
leave it provisionally until the test comes to an
end.
end.
• Feed water to the flexible drain hose and check
the piping for leakage.
• Be sure to check the drain pump for normal oper-
ating and noise when electrical wiring is complete.
• When the test is complete, connect the flexible
drain hose to the drain port on the indoor unit.
Heat insulation material: Polyethylene foam with thickness more than 8 mm.
Drain test
Feed water
Drain Pump
Drain pan
Flexible drain hose
(accessory)
(accessory)
Main
drain pipe
drain pipe
Glue the joint
Drain
port
port
Drain hose connection
Use the clip (accessory)
Use the clip (accessory)