5. Auto Operation
•The operation procedure is as following.
If initial mode is decided, that mode is continued despite of the room temperature changing.
Auto Operation for Cooling
- 20 -
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed
are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode
Over
below
21°C
24°C
Soft Dry
below 21°C
Heating
Over 24°C
Cooling
~
-
-
Intake-Air temp.
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp. -0.5°C
(Compressor ON)
COMPRESSOR
ON
OFF
ON
OFF
INDOOR FAN
Fuzzy Speed
Intake-air Temperature
Setting Temperature
Over 26°C
25°C
Over 24°C~below 26°C
Intake air -1°C
Over 22°C~below 24°C
Intake air -0.5°C
Over 20°C~below 22°C
Intake air temperature
below 20°C
20°C
Over 20°C~below 30°C
Fuzzy control
below 20°C
20°C
over 30°C
30°C
Operation condition
When Auto Operation
initial start
Controlled by
Fuzzy logic
1/f rhythm
Fan speed
Air DirectionControl
When Switch to Auto
Operation
Auto Operation for Soft Dry
• The Setting temperature will be set to the same that of the current intake-air temperature.
- Compressor ON temperature; Setting temperature +1°C
- Compressor OFF temperature; Setting temperture -0.5°C
Auto Operation for Heating
- 21 -
Intake Air temp.
Below 20°C
Over 20°C~below 21°C
Setting temp.
20°C
Intake air temperature +0.5°C
Setting temp.
21°C
20°C
18°C
19°C
20°C
21°C
Intake-Air temp.
Intake air temp.
+0.5°C
- 22 -
6. Natural Wind by CHAOS logic
There are common rules in the irregular changes amid the breeze of highlands and valleys, the sound of
streams, the songs of birds in the forest and brain waves of relaxation.
Mmm... the breath-taking and touchy feeling of wind from the deep mountains and dark valleys.
Through analysis in its chaos simulator, LG has successfully created such a feeling of freshness and sereni-
ty by analyzing the frequency of natural wind.
Generally natural wind has the following character (Frequency-Magnitude), for example dark valley, sea,
mountain wind.
Natural wind function
Frequency(Hz)
Magnitude
So as to make a similar Natural wind function, Indoor fan speed is shifted to high from low or reversely in
according to the CHAOS logic.
7. Heating Mode Operation(Heating Model)
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
8. Hot- Start Control(Heating Model)
• The indoor fan stops until the evaporator piping temperature will be reached at 28°C.(BY TEMPERATURE)
• The operation diagram is as following.
- 23 -
Intake Air temp.
SETTING TEMP. +3°C
(Compressor OFF)
Setting temp.
(Compressor ON)
Selecting
fan speed
Selecting
fan speed
minimum
10sec.
minimum
10sec.
minimum
10sec.
Hot
Start
A
35
°C
26
°C
B
A
COMPRESSOR
ON
OFF
ON
OFF
• A point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
• B point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
INDOOR FAN
OFF
LOW
OFF
LOW
LOW
LOW
PIPE
TEMP 28°C
60sec.
INDOOR
FAN
OFF
LOW
SELECTING
FAN SPEED
COMPRESSOR
ON
(HOT-START BY TEMPERATURE)
Page of 101
Display

Click on the first or last page to see other LM-1962C2N_M_D service manuals if exist.