- 66 -
2. Outdoor(Heating Model)
Possible Trouble 1
: The unit does not operate.
Is the trans input power
AC240V?
Is the trans output power
about AC14V?
Is input voltage of IC2
DC12V?
Is output voltage of IC3
DC5V?
Is the reset circuit
all right?
Is output voltage No 42
of IC1 DC5V?
Check the fuse check
the wiring diagram.
Is shorted the
trans output?
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
Check the main P.C.B
pattern.
Exchange the trans.
Exchange BD11, D11.
Exchange IC3.
Check and exchange
IC4.
Check the DC P.C.B
pattern.
- 67 -
Check the Indoor unit.
Check the setting temp.
(Indoor)
Check the connection line
of outdoor to Indoor.
Communication error
• The control data can be transmitted or received between indoor and outdoor unit with one signal cable.
• If the data be disturbed by any noise level, the unit will be operated incorrectly. In this case, the indoor unit
blinks the operation and operation LED on display and indoor fan, outdoor fan, COMP are not operated.
• The unit can be reoperated by On/Off control of Remocon.
- 58 -
Electronic Parts Troubleshooting Guide
Possible Trouble 1
: The unit does not operate.
Is the trans input power
AC240V?
Is the trans output power
about AC15V?
Is input voltage of IC2
DC16V?
Is output voltage of IC2
DC12V?
Is output voltage of IC3
DC5V?
Is the reset circuit
all right?
Is output voltage of
IC1 PIN3,51 DC5V?
Check the fuse check
the wiring diagram.
Is shorted the
trans output?
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
Check the main P.C.B
pattern.
Exchange the trans.
Exchange BD01.
Exchange IC2.
Exchange IC3.
Check and exchange
IC4.
Check the DC 5V
P.C.B pattern.
Exchange IC1
1-1. Indoor(Cooling Model)
- 59 -
Possible Trouble 2
: Fan does not operate.
Is it the DRY Mode?
Is the IC8 O.K?
Is the each Relay all right?
Exchange the defect
Relay.
Check the FAN Motor and
Check the Relay.
Does the temperature
set all right?
YES
YES
NO
NO
NO
NO
YES
YES
Adjust setting temp.
Exchange the IC8.
Page of 101