DOWNLOAD LG LM-1962C2N_M_D Service Manual ↓ Size: 2.27 MB | Pages: 101 in PDF or view online for FREE

Model
LM-1962C2N_M_D
Pages
101
Size
2.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lm-1962c2n-m-d.zip
Date

LG LM-1962C2N_M_D Service Manual ▷ View online

3828AP3648D
8
-
LM-2162H/M/D(A-UNIT) Cooling & Heating (Indoor Unit)
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
733010
149303
346811
346811-1
346811-2
131410
135501
359011
342800
354210
354210-1
35211B
35211B-1
W6711
249951
235000
261704
261704-1
W6640
268712
268714
268714-1
263230
263230-1
146811
352150
135311
135313
135312
159901-1
159901
152312
135511
145200
135090
135080
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
1H00843A
3H03651A
4680AR2385K
4680AR2385L
4681AR2659L
3141AR2261B
3H03652A
2H02426A
3H02821A
5420AR2505B
5420AR2407A
5211AR2072
2H02449A
6711AR2664D
3A00375D
3H01420A
3A00375A
4995AR1468W
4994AR1236A
6171AQ2147B
6171AQ2258A
4H03048B
6047AQ3021E
6871AQ2146P
6871AQ2379C
3Q35099E
6323AQ2333A
2H01803B
5251AR1222C
5009AR1179K
5236AR1383A
3531AR1458D
5990AR3299C
5990AR3300A
5230AR1151A
3550AR3301H
4025AR4107A
3509AR3459A
3508AR2243A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PLATE ASSY, INSTALL
HOLDER, TUBING
MOTOR ASSY, AC
CHASSIS ASSY
COVER, TUBING
FAN ASSY, CROSS FLOW 
BEARING
EVAPORATOR ASSY
EVAPORATOR ASSY
TUBE ASSY, TUBING
REMOTE CONTROLLER ASSY
SOCKET(MECH),  FLARE
SOCKET(MECH),  FLARE
CONTROL BOX ASSY(INDOOR)
BOARD CONTROL(INDOOR) 
TRANSFORMER, POWER 
TERMINAL BLOCK
PWB(PCB) ASSY, DISPLAY 
PWB(PCB) ASSY, MAIN
THERMISTOR ASSY
MOTOR ASSY, STEP
HOSE ASSY, DRAIN 
GRILLE ASSY, DISCHARGE 
GRILLE ASSY, INLET
GRILLE ASSY, FRONT 
VANE, HORIZONTAL
VANE, HORIZONTAL
FILTER ASSY, AC
COVER ASSY, CONTROL(INDOOR)
LINK
DECORATION ASSY
DECORATION
3828AP3648D
9
-
LM-2162H/M/D(B-UNIT) Cooling & Heating (Indoor Unit)
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
733010
149303
346811
346811-1
346811-2
131410
135501
359011
342800
354210
354210-1
35211B
35211B-1
W6711
249951
235000
261704
261704-1
W6640
268712
268714
268714-1
263230
263230-1
146811
352150
135311
135313
135312
159901-1
159901
152312
135511
145200
135090
135080
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
1H00843A
3H03651A
4680AR2385K
4680AR2385L
4681AR2659L
3141AR2261B
3H03652A
2H02426A
3H02821A
5420AR2505B
5420AR2407A
5211AR2072D
2H02449
6711AR2664D
3A00375D
3H01420A
3A00375A
4995AR1468V
4994AR1236A
6171AQ2147B
6171AQ2258A
4H03048B
6047AQ3021E
6871AQ2146P
6871AQ2379A
3Q35099E
6323AQ2333A
2H01803B
5251AR1222C
5009AR1179K
5236AR1383A
3531AR1458D
5990AR3299C
5990AR3300A
5230AR1151A
3550AR3301H
4025AR4107A
3509AR3459A
3508AR2243A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PLATE ASSY, INSTALL
HOLDER, TUBING
MOTOR ASSY, AC
CHASSIS ASSY
COVER, TUBING
FAN ASSY, CROSS FLOW 
BEARING
EVAPORATOR ASSY
TUBE ASSY, TUBING
REMOCON CONTROLLER ASSY
SOCKET(MECH),  FLARE
SOCKET(MECH),  FLARE
CONTROL BOX ASSY(INDOOR)
BOARD CONTROL(INDOOR) 
TRANSFORMER, POWER 
TERMINAL BLOCK
PWB(PCB) ASSY, DISPLAY 
PWB(PCB) ASSY, MAIN
THERMISTOR ASSY
MOTOR ASSY, STEP
HOSE ASSY, DRAIN 
GRILLE ASSY, DISCHARGE 
GRILLE ASSY, INLET
GRILLE ASSY, FRONT 
VANE, HORIZONTAL
VANE, HORIZONTAL
FILTER ASSY, AC
COVER ASSY, CONTROL(INDOOR)
LINK
DECORATION ASSY
DECORATION
- 3 -
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Hot-start Control (Heating)
Airflow Direction Control
Deice (defrost) control (Heating)
• Room temperature sensor (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 seconds at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, Chaos
• Intermittent operation of fan at low speed
• The fan is switched to low(Cooling) or med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• Both the indoor and outdoor fan
stops during deicing.
• Hot start after deice ends.
• The fan is switched to intermittent or irregular operation.
• The fan speed is automatically switched from high to low speed.
• The indoor fan stops until the
evaporator piping temperature will
be reached at 28°C.
• The louver can be set at the desired
position or swing up and down automatically.
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode (for Heating Model)
--- Lights up in compressor operation (for Cooling Model)
OUT
DOOR
- 4 -
TEMPERATURE
TEMPERATURE
LOW
LOW
HIGH
HIGH
Remote Controller
Operation ON/OFF
(Cooling model only) (Heating model only)
Cooling Operation Mode (
)
Soft Dry Operation Mode (
)
(Low)
(Med)
(High)
: High: 39°C
LOW : 11°C
Down to 18°C
Up to 30°C,
Cooling
: OFF, ON, OFF
ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Auto Operation Mode (
)
Heating Operation Mode (
)
Operation Mode Selection
Fan Speed Selection
Room, Temperature Display
Temperature Setting
Setting the Time or timer
Timer Selection
Timer Setting
Timer Cancel
Sleep Operation
Airflow Direction Control
Fan Operation Mode
Reset
Down to 16°C
Up to 30°C,
Heating
Page of 101
Display

Click on the first or last page to see other LM-1962C2N_M_D service manuals if exist.