DOWNLOAD LG LB-F4280HL / LB-F4280CL Service Manual ↓ Size: 916.15 KB | Pages: 42 in PDF or view online for FREE

Model
LB-F4280HL LB-F4280CL
Pages
42
Size
916.15 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lb-f4280hl-lb-f4280cl.zip
Date

LG LB-F4280HL / LB-F4280CL Service Manual ▷ View online

–41–
Parts List (Outdoor Unit )
PART No. 
Location No.
Description
Remarks
LB-F4280HL
LB-F4280CL
135301
3530AP1225B
3530AP1225B
GRILLE, DISCHARGE
R
137213
3720AP1215B
3720AP1215B
PANEL, SIDE
R
263230
3Q35015E
3Q35015E
THERMISTOR ASSY
R
268711
6871A20015N
6871A20015N
PWB(PCB) ASSY, DEICER
R
430410
3041AP2569B
3041AP2569B
BASE ASSY, WELD[OUTDOOR]
R
435511
3551A30014G
3551A30014G
COVER ASSY, CONTROL(OUTDOOR)
R
435512
3550AP1213B
3550AP1213B
COVER ASSY, TOP(OUTDOOR)
R
437210
3720AP1212B
3720AP1212B
PANEL ASSY, FRONT SUB
R
437212
3720AP1202C
3720AP1202C
PANEL ASSY, REAR
R
546810
4680AP2135M
4681A20008P
MOTOR ASSY, AC
R
552201
3A01020D
3A01020D
VALVE, CHECK
R
552202
3A02080A
-
COIL ASSY, REVERSING VALVE
R
552203-1
2A00393Q
2A00393P
VALVE, SERVICE
R
552203-2
2A00499A
2A00499A
VALVE, SERVICE
R
554031-1
5403AP2378V
5403A20014H
CONDENSER ASSY, BENT
R
554031-2
5403AP2378X
5403A20014H
CONDENSER ASSY, BENT
R
554160
5416AR1411K
5416AR1411K
COMPRESSOR
R
559010
1A00195B
1A00195B
FAN ASSY, PROPELLER
R
561410
3A02028B
-
COIL ASSY, REVERSING VALVE
R
566000
3A01100A
3A01100A
SWITCH, PRESSURE
R
649950
6615AP2772M
6615AP2772J
CONTROL BOX ASSY, OUTDOOR
R
666000
2A01031A
2A01031C
SWITCH, MAGNET
R
669200
3A00261C
-
RELAY
R
W0CZZ
2A00986D
2A00986D
CAPACITOR, DRAWING
R
P/No.: 3828A30025P
January, 2001
Dimensions
Model:LB-F4280HL/CL
(1) Indoor Unit 
900
1225
370
1180
600
298
–6–
(2) Outdoor Unit 
Refrigeration Cycle Diagram
LB-F4280HL
(
§
Rated performance for refrigerant line length of: 5m)
For installation over rated distance, 70g of refrigerant should be added for each meter.
ex) When installed at a distance of 15m, 700g of refrigerant should be added.
(15-5) x 70g = 700g
Pipe size(Diameter: ø)
Piping length(m)
Elevation(m)
MODEL
Gas
Liquid
Rated
Max.
Rated
Max.
LB-F4280HL
3/4"
3/8"
5
40
5
30
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGER
HEAT
EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING
HEATING
REVERSING
VALVE
CHECK VALVE
CAPILLARY TUBE
–7–
Page of 42
Display

Click on the first or last page to see other LB-F4280HL / LB-F4280CL service manuals if exist.