LG LB-D2460HL Service Manual ▷ View online
Functions
ƒU
Room temperature sensor. (Thermistor)
ƒU
Maintains the room temperature in accordance with the Setting Temp.
ƒU
Indoor fan is delayed for 5 seconds at the starting.
ƒU
Restarting is inhibited for approx. 3 minutes.
ƒU
High, Med, Low
ƒU
Intermittent operation of fan at low speed.
ƒU
The setting temperature, indoor fan speed and desired operation mode are automatically set.
ƒU
Both the indoor and outdoor fan stops during defrosting.
ƒU
Hot start after defrost ends.
ƒU
The indoor fan stops until the evaporator piping temperature will be reached at 28
¡
.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Soft Dry Operation Mode
Deice (defrost) control (Heating)
Hot-start Control (Heating)
Auto Operation
–3–
–4–
Remote Controller
Operation ON/OFF
Operation Mode Selection
Fan Speed Selection
Room Temperature Display
Temperature Setting
Setting the Time or Timer
(Cooling
model only)
(Heating
model only)
(Low)
(Med)
(High)
Cooling Operation Mode ( )
Heating Operation Mode ( )
Heating Operation Mode ( )
Soft Dry Operation Mode ( )
Fan Operation Mode
HI
MED
LO
Set
: High:39°C
¡Œ
LOW:11°C
: Fan Operates without cooling & heating
Cooling
Heating
Down to 18°C
Up to 30°C
,
Down to 16°C
Up to 30°C
,
When the air conditioner is turned off by a power failure, it is restarted
automatically after a power resupply.
automatically after a power resupply.
✓
Product Specifications (Cooling & Heating)
Air Circulation
m
3
/min
Dimensions
(W
¡¿
H
¡¿
D)
Net. Weight
mm
kg
W
A
LB-D2460HL
–5–
Service Valve &
Connecting Tube
Connecting Tube
Model Name
Item
Unit
Cooling Capacity
Btu/h(W)
Heating Capacity
Btu/h(W)
Moisture Removal
§⁄
/h
Power Source
§j
, V, Hz
Indoor
Outdoor
Input
Cooling
Heating
Running Current
Cooling
Heating
E.E.R.
Btu/h-W
Indoor
Outdoor
Indoor
Outdoor
Refrigerant (R-22)
g
Remocon Type
Liquid
Gas
Drain Hose
Connecting Wire
Main Power Cable
Time Delay Safety Function
Soft Dry
Fan Speed (Indoor)
Timer
Self-Diagnosis
24,000(7,033)
24,000(7,033)
3.5
1Ø
,
220-240V, 50Hz
20
49
3,100
3,050
15
15
8.6
880 x 281 x 575
870 x 655 x 320
42
62
1,860
L.C.D
3/8" (9.52)
5/8" (15.88)
O
0.75mm
2
¤C
3.5mm
2
¤C
O
O
3 (Hi, Med, Low)
24Hrs
O
Dimensions
MODEL:LB-D2460HL
Indoor Unit
870
655
320
880
575
281
–6–
Outdoor Unit