–4–
Remote Controller
Operation ON/OFF
Operation Mode Selection
Fan Speed Selection
Room Temperature Display
Temperature Setting
Setting the Timer 
Weekly Program
(Cooling 
model only)
(Heating 
model only)
(Low)
(Med)
(High)
Cooling Operation Mode (       )
Heating Operation Mode (       )
Auto Operation Mode (       )
Soft Dry Operation Mode (       )
Fan Operation Mode
HI
AUTO
MED
LO
Program
Holiday
SET/CLR
Min
Hour
Week
Timer
Cancel
Timer
Cancel
: High:39°C 
LOW:11°C
: Fan Operates without cooling & heating
Cooling
Heating 
Down to 18°C
Up to 30°C
Down to 16°C
Up to 30°C
–22–
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit 
Select location
Install the air conditioner in the location that satis-
fies the following conditions.
• The place shall easily bear a load exceeding four
times the indoor unit’s weight.
• The place shall be able to inspect the unit as the
figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suit-
able dimension “H” is necessary to get a slope to
drain as figure.)
• The place shall easily connect with the outdoor
unit.
• The place where the unit is not affected by an
electrical noise.
• The place where air circulation in the room will be
good .
• There should not be any heat source or steam
near the unit.
2) Outdoor unit
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted. 
• There should not be any animals or plants which
could be affected by hot air discharged. 
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
3) Piping length and the elevation
Indoor unit
Outdoor unit
B
A
More than
30cm
More than
30cm
More than
70cm
Sunr
oof
Fence or
obstacles
Top view
(unit: mm)
H
Front view
600
600
Front
Inspection hole
(600X600)
Control box
1000
• If 18K Model is installed at a distance of 15m, 
188g of refrigerant should be added (15-7.5) x 25g = 188g
• Capacity is based on standard length and maximun allowance length is on the basis of reliability.
18K BTU/h
5/8"
5/8"
5/8"
1/4"
7.5
50
5
30
25
30K BTU/h
5/8"
3/8"
7.5
50
5
30
50
42K BTU/h
3/4"
3/8"
7.5
50
5
30
50
H/P
1/4"
7.5
50
5
30
30
5/8"
3/8"
7.5
50
5
30
40
5/8"
3/8"
7.5
50
5
30
40
C/O
H/P
C/O
1/4"
7.5
50
5
30
30
30
25
48K BTU/h
3/4''
3/8"
7.5
50
5
50
3/4"
1/2"
7.5
50
5
60
60K BTU/h
24K
BTU/h
36K
BTU/h
Capacity
Gas
Liquid
Elevation B(m)
Length A(m)
* Additional
refrigerant
(g/m)
Pipe Size
(Diameter: Ø)
Standard
Standard
Max.
Max.
–31–
• Drill the piping hole with 70mm dia, hole
core drill.
• Piping hole should be slightly slant to the
outdoor side.
INSULATION, OTHERS
Insulate the joint and tubes completely.
All thermal insulation must comply with local requirement.
INDOOR UNIT
REFRIGERANT PIPE
• Insulate and tape both the gas piping and liquid piping.
THERMAL INSULATION
5~7mm
Indoor
Outdoor
WALL
Make sure that there is no clearance here.
Overlap with thermal
insulator for piping.
Thermal insulator for refrigerant pipe
(Local supply)
Thermal insulator for
piping(Local supply)
Hose crip for thermal insulator(Local supply)
Union for liquid pipe
Refrigerant pipe and thermal
insulator(Local supply)
Union for gas pipe
Thermal insulator for refrigerant pipe
(Local supply)
Hose crip for thermal insulator
(Local supply)
Connecting cable
Liquid pipe
Thermal insulator
Gas pipe
Tape
1. Wrap the connecting portion of indoor unit with
the Insulation material and secure it with two
Plastic Bands. (for the right pipings)
• If you want to connect an additional drain hose,
the end of the drain-outlet should keep distance
from the ground. (Do not dip it into water, and fix
it on the wall to avoid swinging in the wind.) 
2. Tape the Pipings, drain hose and Connecting
Cable from bottom to top.
3. Form the pipings gathered by taping along the
exterior wall and fix it onto the wall by saddle
or equivalent.
–32–
1) PRECAUTIONS IN TEST RUN
• The initial power supply must provide at least 90% of the rated voltage.
Otherwise, the air conditioner should not be operated.
For test run, carry out the cooling operation firstly even during heating season. If heating operation
is carried out firstly, it leads to the trouble of compressor. Then attention must be paid.
Carry out the test run more than 5 minutes without fail.
(Test run will be cancelled 18 minutes later automatically)
• The test run is started by pressing the room temperature checking button and down timer button for 3 sec-
onds at the same time.
• To cancel the test run, press any button.
• After completing work, be sure to measure and record trial run properties, and store measured data, etc.
• Measuring items are room temperature, outside temperature, suction temperature, blow out temperature, wind
velocity, wind volume, voltage, current, presence of abnormal vibration and noise, operating pressure, piping
temperature, compressive pressure.
• As to the structure and appearance, check following items.
CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETE
Caution
Is the circulation of air adequate?
Is the draining smooth?
Is the heat insulation complete
(refrigerant and drain piping)?
Is there any leakage of refrigerant?
Is the remote controller switch operated?
Is there any faulty wiring?
Are not terminal screws loosened?
M4...118N.cm{12kgf.cm}
M5...196N.cm{20kgf.cm}
M6...245N.cm{25kgf.cm}
M8...588N.cm{60kgf.cm}
Test running
Trap is required to prevent water from entering 
into electrical parts.
Seal a small opening
around the pipings
with gum type sealer.
Drain hose
Taping
Pipings
Connecting
cable
Power supply
cord
In case of the Outdoor unit being installed
below position of the Indoor unit. 
FORM THE PIPINGS
Page of 62
Display

LG LB-D1861HL_CL / LB-D2461HL_CL / LB-F3061HL / LB-F3661HL_CL / LB-F3681HL_CL / LB-F4261HL / LB-E4881HL_CL / LB-E6081HL_CL Service Manual ▷ Download

  • DOWNLOAD LG LB-D1861HL_CL / LB-D2461HL_CL / LB-F3061HL / LB-F3661HL_CL / LB-F3681HL_CL / LB-F4261HL / LB-E4881HL_CL / LB-E6081HL_CL Service Manual ↓ Size: 1.69 MB | Pages: 62 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LB-D1861HL_CL / LB-D2461HL_CL / LB-F3061HL / LB-F3661HL_CL / LB-F3681HL_CL / LB-F4261HL / LB-E4881HL_CL / LB-E6081HL_CL in PDF for free, which will help you to disassemble, recover, fix and repair LG LB-D1861HL_CL / LB-D2461HL_CL / LB-F3061HL / LB-F3661HL_CL / LB-F3681HL_CL / LB-F4261HL / LB-E4881HL_CL / LB-E6081HL_CL Air Conditioner. Information contained in LG LB-D1861HL_CL / LB-D2461HL_CL / LB-F3061HL / LB-F3661HL_CL / LB-F3681HL_CL / LB-F4261HL / LB-E4881HL_CL / LB-E6081HL_CL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.