DOWNLOAD LG AS-H186V_L1_L2 Service Manual ↓ Size: 4.48 MB | Pages: 63 in PDF or view online for FREE

Model
AS-H186V_L1_L2
Pages
63
Size
4.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
as-h186v-l1-l2.zip
Date

LG AS-H186V_L1_L2 Service Manual ▷ View online

Service Manual  3
LG Model Name
LG Model Name
2004
1
2
-
3
4
5
6
7
8
9
10
Code 
Type
Code of Model
Meaning
1
Producing Center, 
A~Z
L: Chang-won R22
N: India
Refrigerant
A: Chang-won R410A
Z: Brazil
C: Chang-won R407C
D: Indonesia
T: China
M: Mexico
U: China R410A
K: Turkey R22
V: Vietnam
E: Turkey R410A
S: Out Sourcing
H: Thailand
2
Product Type
A~Z
S: Split Type Air Conditioner
3
Cooling/Heating/Inverter
A~Z
C: Cooling only
H: Heat pump
X: C/O + E/Heater
Z: H/P + E/Heater
V: AC Inverter C/O
N: AC Inverter H/P
Q: DC Inverter C/O
W: DC Inverter H/P
4, 5
Capacity
0~9
Cooling/Heating Capacity
Ex. "09" 
→ 9,000 Btu/h
6
Electric Range
1~9
1: 115V/60Hz,
A: 220V, 50Hz, 3Phase
A~Z
2: 220V/60Hz
B: 208~230V, 60Hz, 3Phase
3: 208-230V/60Hz 
C: 575V, 50Hz, 3Phase
5: 200-220V/50Hz
D: 440~460, 60Hz, 3Phase
6: 220-240V/50Hz
E: 265V, 60Hz
7: 110V, 50/60Hz
F: 200V, 50/60Hz
8: 380-415V/50Hz
9: 380-415V/60Hz
7
Chassis
A~Z
Name of Chassis of Unit
Ex. LSP 
→ SP Chassis
8
Look
A~Z
Look,
Color (Artcool Model)
9
Function
A~Z
10
Serial No.
1~9
LG Model Development Serial No.
Basic
A
Basic+4Way
B
Plasma Filter
C
Plasma Filter+4 Way
D
Tele+LCD
E
Tele+LCD+Nano plasma+4Way
F
Nano Plasma F+(A/changeove)+A/clean+Low A
G
Nano Plasma F+(A/changeove)+A/clean+4way+Low A
H
Tele+LED+4way
I
Internet
J
Plasma F+4Way+Oxy generator
K
Nano Plasma F+(A/changeove)+A/clean
L
Nano Plasma F+(A/changeove)+A/clean+4way
M
Nano Plasma F+(A/changeove)+A/clean+PTC
N
Nano Plasma F+(A/changeove)+Autoclean+4way+PTC
P
Nano Plasma F+(A/changeove)+A/clean+4way+Low A+PTC
Q
Negative ION+A/Clean
R
(Nano)Plasma+Negative ION+A/Clean
S
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean
T
Nano Plasma F+4Way+(A/changeove)+A/clean+Oxy generator
U
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean+Oxy generator
V
Dry Contact
W
Wired Remocon
8
* ARTCOOL COLOR
R
Mirror
W
White
B
Blue
D
Wood
M
Metal
C
Cherry
N
Walnut
A
Gogh
S
Sisley
Q
Quran
K
Mecca
Room Air Conditioner
Safety Precautions   
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
■ Be sure to read before installing the air conditioner.
■ Be sure to observe the cautions specified here as they include important items related to safety.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the
following indications.
■ Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
WARNING
■ Installation
Always perform grounding.
• Otherwise, it may cause electrical shock.
Don’t use a power cord, a plug or a loose socket
which is damaged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the product, always contact the
service center or a professional installation agency.
• Otherwise, it may cause a fire, electrical shock, explo-
sion or injury.
Securely attach the electrical part cover to the indoor
unit and the service panel to the outdoor unit.
• If the electrical part cover of the indoor unit and the
service panel of the outdoor unit are not attached
securely, it could result in a fire or electric shock due to
dust, water, etc.
Be sure not to do.
Be sure to follow the instruction.
Service Manual  5
Safety Precautions  
■ Operational
Always install an air leakage
breaker and a dedicated switch-
ing board.
• No installation may cause a fire and
electrical shock.
Do not keep or use flammable
gases or combustibles near the
air conditioner.
• Otherwise, it may cause a fire or
the failure of product.
Ensure that an installation frame
of the outdoor unit is not dam-
aged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the
product randomly.
• It will cause a fire or electrical
shock.
Do not install the product at a
place that ther is concern of
falling down.
• Otherwise, it may result in personal
injury.
Use caution when unpacking and
installing.
• Sharp edges may cause injury.
Unplug the unit if strange
sounds, odors, or smoke
come from it.
• Otherwise it may cause fire and
electric shock accident.
Do not use the socket if it is
loose or damaged.
• It may cause fire and electric
shock.
Do not operate with wet hands
or in damp environment.
• It will cause electric shock.
Take care so that the power cord
may not be pulled during opera-
tion.
• Otherwise, it may cause a fire or
electrical shock.
Unplug the unit if strange
sounds, smell, or smoke comes
from it.
• Otherwise, it may cause electrical
shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
Wa
x Thinner
Room Air Conditioner
Safety Precautions  
Take the power plug out if neces-
sary, holding the head of the plug
and do not touch it with wet hands.
• Otherwise, it may cause a fire or
electrical shock.
Do not use the power cord near
the heating tools.
• Otherwise, it may cause a fire and
electrical shock.
Do not open the suction inlet of
the indoor/outdoor unit during
operation.
• Otherwise, it may electrical shock
and failure.
Do not allow water to run into
electrical parts.
• Otherwise, it may cause the failure
of machine or electrical shock.
Hold the plug by the head when
taking it out.
• It may cause electric shock and
damage.
Never touch the metal parts of
the unit when removing the filter.
• They are sharp and may cause
injury.
Do not step on the indoor/outdoor unit and do not
put anything on it.
• It may cause an injury through dropping of the unit or
falling down.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water, always
contact the service center.
• Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the out-
door unit.
• Otherwise, children may be seriously injured due to
falling down.
Page of 63
Display

LG AS-H186V_L1_L2 Service Manual ▷ Download

  • DOWNLOAD LG AS-H186V_L1_L2 Service Manual ↓ Size: 4.48 MB | Pages: 63 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG AS-H186V_L1_L2 in PDF for free, which will help you to disassemble, recover, fix and repair LG AS-H186V_L1_L2 Air Conditioner. Information contained in LG AS-H186V_L1_L2 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.