Date

LG AS-H126U / LS-C126U / LS-H126U Service Manual ▷ View online

17
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Power
button
Operation procedures when the remote
control can't be used.
The operation will be started if the power
button is pressed.
If you want to stop operation, re-press
the button.
Forced Operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. 
24°C
21°C 
Room Temp. < 24°C
Room Temp. < 21°C
Operating mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor FAN Speed
High
High
High
High
Setting Temperature
22°C
22°C
23°C
24°C
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the
value when the fan speed is set to high, and the capacity will
be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the
room quickly.
High
Speed
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be
pressed for about 3 seconds.
If you want to stop the operation, re-press the button.
ENGLISH
18
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Front panel
Panel hook
Air filters
Air filters
Gasoline
Powder
Indoor Unit
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or discoloration.
• Volatile substances
Could damage the surfaces of the air conditioner.
1. Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
2. Clean the filter with a vacuum cleaner or warm,
soapy water.
• If dirt is conspicuous, wash with a solution of
detergent in lukewarm water.
• If hot water (40°C or more) is used, it may be
deformed.
3. After washing with water, dry well in the shade.
4. Re-install the air filter. 
1. After removing the air filters, pull slightly forward to
remove the PLASMA filter.
2. Dip the PLASMA filter into the water mixed with
neutral detergent, for 20~30 minutes.
3. Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed
perfectly on this parts).
4. Note the cuts of electric discharge lines.
5. Re-install the PLASMA filter to the original position.
Open the upside of Front Panel
1
Relocate dried air filters at the shade and then
close the panel.
5
Put up the Front panel.
The hook of panel comes off.
2
Come down the panel and then remove 
air filters.
3
Do cleaning by soft brush and a vacuum
cleaner. If it has hard pollution, wash by
water.
4
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
19
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Front panel
Panel
hook
Plasma
filters
(Side)
(Rear)
Air intake
vents
Air outlet
vents
(Side)
(Rear)
Drain Hose
Air intake vents
Air outlet vents
Piping
(Side)
(Rear)
Piping
Drain Hose
Air intake
vents
Air outlet
vents
Piping
Drain Hose
Outdoor Unit
The heat exchanger coils and panel vents of the
outdoor unit should be checked regularly. If clogged
with dirt or soot, the heat exchanger and panel 
vents may be professionally steam cleaned.
NOTE:
Dirty or clogged coils will reduce the 
operating efficiency of the system and cause
higher operating costs.
Cleaning of Purifying Filter
• Recomended use period : About 3 months
Open the upside of Front
panel.
Put up the front panel.
The hook of panel comes off.
Remove air filters and then
pull out plasma filter
3
2
1
Put in plasma filters in the
neutral detergent for 1~2
hours and then raise them.
Relocate dried plasma filters
at the shade and then put in
air filters.
5
4
ENGLISH
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
2
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
Safety precautions
Safety Precautions
Warning ................................2
Caution .................................3
Operating Instructions
Preparation before operation ..4
Remote Control Features .....6
Operation Mode Selection ......7
Additional features ..............14
Care and Maintenance
Care and Maintenance .......18
Operation Tips ....................20
Troubleshooting tips
Before You 
Call For Service 
...............21
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions will cause harm or
damage, the seriousness of which is indicated by the following
symbols.
This symbol shows the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to
property.
■ 
The following items are classified by these symblos.
Never Do This
Always Do This
Plug in the power plug
properly.
Do not operate or stop the unit by
inserting or pulling out the power plug.
Do not damage or use an
unspecified power cord.
• Otherwise, it will cause electric shock
or fire due to heat generation or
electric shock.
• It will cause electric shock or fire due
to heat generation.
• It will cause electric shock or fire.
• In the supply cord is damaged, it mut
be replaced by the manufacturer or
its service agent or a similarly
quallfied person in order to avoid a
hazard. (Y Attachment)
Do not modify power cord length or
share the outlet with other appliances.
Do not operate with wet hands or in
damp environment.
Do not direct airflow at room occupants
only.
• It will cause electric shock or fire due
to heat generation.
• It may cause electric shock.
• This could damage your health.
Always perform grounding work.
Do not allow water to run into
electric parts.
Always install air leakage breaker
and a dedicated switching board.
• No grounding may cause electric
shock.
• It may cause failure of machine or
electric shock.
• No installation may cause fire and
electric shock accident.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
Do not use the socket if it is
loose or damaged.
Do not open the entrance
during operation.
• It may cause fire and electric
shock accident.
• It may cause fire and electric
shock.
• It may cause electric shock.
Keep firearms away.
Do not use the power cord close to the
heating tools.
Do not use the power cord near flammable
gas or combustibles, such as gasoline,
benzene, thinner, etc.
• It may cause fire.
• It may cause fire and electric shock.
• It may cause an explosion or fire.
Page of 127