DOWNLOAD LG AS-H126U / LS-C126U / LS-H126U Service Manual ↓ Size: 8.66 MB | Pages: 127 in PDF or view online for FREE

Model
AS-H126U LS-C126U LS-H126U
Pages
127
Size
8.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
as-h126u-ls-c126u-ls-h126u.zip
Date

LG AS-H126U / LS-C126U / LS-H126U Service Manual ▷ View online

-61-
Parts List(Outdoor)
NOTE) 
*
Please ensure GCSC since these parts may be changed depending upon the buyer's request.
430410
BASE ASSEMBLY, OUTDOOR
3041A20008J
3041A20008K
3041A20008K
R
435511
COVER ASSEMBLY, CONTROL
3551A30023C
3551A30023D
3551A30023E
R
437210
PANEL ASSEMBLY, FRONT
3721A20027B
3721A20027B
3721A20027B
R
437212
PANEL ASSEMBLY REAR
3721A20026A
3721A20026B
3721A20026A
R
447910
BARRIER ASSEMBLY, OUTDOOR
4791A30002A
4791A30002A
4791A30002A
R
546810
MOTOR ASSEMBLY, OUTDOOR
4681A20004S
4681A20004S
4681A20004S
R
550140
ISOLATOR, COMP.
4H00982E
4H00982E
4H00982E
R
552102-1
TUBE, CAPILLARY BENT
-
5210A21146F
5210A21146J
R
552102-2
TUBE, CAPILLARY BENT
5210A21147B
5210A21147A
5210A21146K
R
552111
TUBE ASSEMBLY, CAPILLARY
5211A20133G
5211A2014IU
5211A2014IY
R
552116
TUBE ASSEMBLY, REVERSING
-
5211A20140R
5211A20140V
R
552201
VALVE, CHECK
-
3H01552F
5220AR7182A
R
552202
VALVE, REVERSING
-
5220AR3084A
5220AR3228D
R
552203-1
VALVE, SERVICE
2H02479H
5220A20005A
2H02479H
R
552203-2
VALVE, SERVICE
2H01890L
5220A20003A
5220A20006B
R
554031
CONDENSER ASSEMBLY, BENT
5403A20026K
5403A20026F
5403A20019V
R
554160
COMPRESSOR
5416A20008C
5416A20008C
2520UGHP2AA
R
559010
FAN ASSEMBLY, PROPELLER
5901A10004A
5901A10004A
5901A10004A
R
W0CZZ
CAPACITOR, DRAWING
2H01451T
2H01451T
2H01451T
R
435301
GRILLE, DISCHARGE
3530A20006B
3530A20006B
3530A20006B
R
56141
COIL ASSEMBLY, REVERSING VALVE
-
3A02028Y
6141AR3733R
R
649950
CONTROL BOX ASSEMBLY, OUTDOOR
4995A20083W
4995A20083Y
4995A20083Y
R
LOCATION
DESCRIPTION
PART No.
REMARKS
No.
LS-C126U*D0
LS-H126U*D0
AS-H126U*D0
P/No.: 3828A20195G
February, 2003
Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp. 
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, CHAOS, JET COOL
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed. 
• The louver can be set at the desired position or swing 
up and down automatically. 
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Soft Dry Operation Mode
• The function will be operated while in any
operation mode with selecting the function.
• The function is to be stopped while it is
operating with selecting the function.
• Both the indoor and outdoor fan  stops dur-
ing defrosting.
• The indoor fan stops until the 
evaporator pipe temperature will be reached
at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
-4-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
PLASMA
-5-
Cooling Mode
Lights up during Cooling operation. (Outline)
Auto Operation Mode
Lights up during Auto operation. (Outline)
Healthy Dehumidification
Lights up during Healthy Dehumidification operation. (Outline)
Mode
Heating Mode
Lights up during Heating operation.
(Heat Pump model only) (Outline)
Defrost Mode
Lights up during Defrost control or
Hot Start in Heating operation. (Outline)
Air circulation Mode
Lights up during Air Circulation operation. (Outline)
Sleep Mode
Lights up during Sleep Mode operation.
Timer Mode
Lights up during Timer operation.
Auto Cleaning Mode
Lights up during Auto Cleaning reservation.
Jet Cool Mode
Lights up during Jet Cool Operation.
Plasma
Lights up during Plasma operation.
Fan Speed (Low)
Lights up when Fan speed is low.
Fan Speed (Medium)    Lights up when Fan speed is Medium.
Fan Speed (High)    Lights up when Fan speed is High.
Fan Speed (Chaos)    Lights up when Fan speed is Chaos.
Desire temperature  For cooling,dehumidification,heating modes it display Desired temperature
indicator
• Cooling
: 18~30
°
C
• AI : Auto Operation
• Dehumidification : 18~30
°
C
• Po : Jet Cool
• Heating
: 16~30
°
C
• Lo : Test Mode 
 
• C1 : Indoor pipe sensor error
Desire temperature Icon
Indoor temperature Icon
Signal Receptor
Each Icon turns on when the unit is operated, then the only Icon outline to be operated is bright.
Page of 127