JBL VOYAGER (serv.man2) EMC - CB Certificate ▷ View online
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 46 of 58
5.7.3 TEST SETUP
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 47 of 58
5.7.4 TEST RESULTS
EUT
Wireless speaker system
Mode Number
JBL VOYAGER
Test date
2013-08-08
Voltage Supply
AC 230V/50HZ
Test Engineer
Bruce
environment
Tem:23℃ Hum:57 %101kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
(adapter)
2. Test the EUT in mode 2:
BT
(adapter)
3. Test the EUT in mode 3:
BT
(battery)
4. Test the EUT in mode 4: Standby
Frequency
Band (MHz)
Field
Strength
(Vrms)
Cable
Injection
Method
Required
Passing
Performance
Actual
performance
Result
0.15-80
3
AC Line CDN-M2/M3 Criterion A Criterion A*
PASS
A*: EUT is working on intended use operation, no abnormal phenomena were observed.
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 48 of 58
5.8 VOLTAGE DIP & VOLTAGE INTERRUPTIONS
5.8.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-11:2004
Test duration time
Voltage dips:
30 during 25 periods,
Meets the requirements of Performance Criterion C
Meets the requirements of Performance Criterion C
Voltage interruption:
100% during 0.5 cycles,
100% during 1 cycles,
100% during 1 cycles,
Meets the requirements of Performance Criterion B
100% during 250 cycles,
Meets the requirements of Performance Criterion C
Interval between event
10s for each dips at each test angle
Phase Angle
0°
Test cycle
3
5.8.2 TEST PROCEDURE
a) The EUT and test generator were setup as shown on Section
b) The interruptions is introduced at selected phase angles with specified duration.
b) The interruptions is introduced at selected phase angles with specified duration.
c) Record any degradation of performance.
5.8.3 TEST SETUP
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 49 of 58
5.8.4 TEST RESULTS
EUT
Wireless speaker system
Mode Number
JBL VOYAGER
Test date
2013-08-08
Voltage Supply
AC 230V/50HZ
Test Engineer
Bruce
environment
Tem:20℃ Hum:54 %101kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
(adapter)
2. Test the EUT in mode 2:
BT
(adapter)
3. Test the EUT in mode 3:
BT
(battery)
4. Test the EUT in mode 4: Standby
Voltage
(% Reduction)
Duration
(Period)
Angle
Required
Passing
Performance
Actual
performance
Test
Result
Voltage
dips
100% 0.5
0°
Criterion B
A*
PASS
180°
Voltage
dips
100% 1
0°
Criterion B
A*
PASS
180°
Voltage
dips
30% 25
0°
Criterion B
A*
PASS
180°
Voltage
interruptions
100% 250
0°
Criterion C
A*
PASS
180°
Note: A*: EUT is working on intended use operation, no abnormal phenomenon was observed.
B*: There was the EUT shut up and restore to the original working state automatically.
C*: There was the EUT shut up and need restart by the operator.
C*: There was the EUT shut up and need restart by the operator.