Report No.: EM201300534-2 Application No.: ZJ00032799 Page 41 of 58
5.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
5.5.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-4: 2012
Test Voltage
Electrical Fast Transient/Burst – EFT:
AC Power Port: ±1kV,Signal port ±0.5kV
Performance Criterion B
AC Power Port: ±1kV,Signal port ±0.5kV
Performance Criterion B
Polarity
Positive and Negative
Impulse Frequency
5 kHz
Impulse Wave-shape
5 ns/50ns for voltage
Burst Duration
15 ms
Burst Period
300 ms
Test Duration
2 minutes
5.5.2 TEST PROCEDURE
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min.
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m.
For input and AC power ports:
The EUT is connected to the power mains by using a coupling device which couples the EFT
interference signal to AC power lines. Both polarities of the test voltage should be applied during
compliance test and the duration of the test can’t less than 1min.
5.5.3 TEST SETUP
10 cm
isolation
supporter
isolation
supporter
AC
input
EFT
Generator
EUT
AC
AC Line
Ground Reference Plane
0.5m
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 42 of 58
5.5.4 TEST RESULTS
EUT
Wireless speaker system
Mode Number
JBL VOYAGER
Test date
2013-08-08
Voltage Supply
AC 230V/50Hz
Test Engineer
Bruce
environment
Tem:21℃ Hum:54 %101kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
(adapter)
2. Test the EUT in mode 2:
BT
(adapter)
3. Test the EUT in mode 3:
BT
(battery)
4. Test the EUT in mode 4:Standby
Test Point
Polarity
Test Level
(kV)
Required Passing
Performance
Actual
performance
Result
L–N
+/-
1
Criterion B
Criterion A*
PASS
A*: EUT is working on intended use operation, no abnormal phenomenon was observed.
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 43 of 58
5.6 SURGE IMMUNITY TEST
5.6.1 TEST SPECIFICATION
Basic Standard:
EN 61000-4-5:2006
Wave-Shape:
CW 1.2μs/50μs
Test Voltage:
Line to line 0.5kV; line to PE 1kV
Generator Source Impedance:
Line to line 2ohm; line to PE 12ohm
Polarity:
Positive and Negative
Phase Angle:
0°, 90°, 180°, 270°
Pulse Repetition Rate:
60s
Number of Tests:
5 times
5.6.2 TEST PROCEDURE
a) For EUT power supply:
The surge is applied to the EUT power supply terminals via the capacitive coupling network. Decoupling
networks are required in order to avoid possible adverse effects on equipment not under test that may be
powered by the same lines, and to provide sufficient decoupling impedance to the surge wave. The power
cord between the EUT and the coupling/decoupling networks was shorter than 2 meters in length.
The surge is applied to the EUT power supply terminals via the capacitive coupling network. Decoupling
networks are required in order to avoid possible adverse effects on equipment not under test that may be
powered by the same lines, and to provide sufficient decoupling impedance to the surge wave. The power
cord between the EUT and the coupling/decoupling networks was shorter than 2 meters in length.
b) For test applied to unshielded un-symmetrically operated interconnection lines of EUT: The surge was
applied to the lines via the capacitive coupling. The coupling / decoupling networks didn’t influence the
specified functional conditions of the EUT. The interconnection line between the EUT and the
coupling/decoupling networks was shorter than 2 meters in length.
applied to the lines via the capacitive coupling. The coupling / decoupling networks didn’t influence the
specified functional conditions of the EUT. The interconnection line between the EUT and the
coupling/decoupling networks was shorter than 2 meters in length.
c) For test applied to unshielded symmetrically operated interconnection / telecommunication lines of
EUT:The surge was applied to the lines via gas arrestors coupling. Test levels below the ignition point of
the coupling arrestor were not specified. The interconnection line between the EUT and the
coupling/decoupling networks was shorter than 2 meters in length.
EUT:The surge was applied to the lines via gas arrestors coupling. Test levels below the ignition point of
the coupling arrestor were not specified. The interconnection line between the EUT and the
coupling/decoupling networks was shorter than 2 meters in length.
5.6.3 TEST SETUP
Report No.: EM201300534-2 Application No.: ZJ00032799 Page 44 of 58
5.6.4 TEST RESULTS
EUT
Wireless speaker system
Mode Number
JBL VOYAGER
Test date
2013-08-08
Voltage Supply
AC 230V/50Hz
Test Engineer
Bruce
environment
Tem:21℃ Hum:54 %101kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
(adapter)
2. Test the EUT in mode 2:
BT
(adapter)
3. Test the EUT in mode3:
BT
(battery)
4. Test the EUT in mode 4:Standby
Test Point Polarity
Test
Level
(kV)
Phase
Performance
Criterion
Actual
performance
Result
(P/F)
L - N
+/- 1 0° B
A
*
PASS
+/- 1 90° B
A
*
PASS
+/- 1
180° B
A
*
PASS
+/- 1
270° B
A
*
PASS
B*: EUT is working and it has some noise and the volume is descended. It can recover after test.