DOWNLOAD JBL VOYAGER (serv.man2) Service Manual ↓ Size: 1.69 MB | Pages: 58 in PDF or view online for FREE

Model
VOYAGER (serv.man2)
Pages
58
Size
1.69 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
voyager-sm2.pdf
Date

JBL VOYAGER (serv.man2) EMC - CB Certificate ▷ View online

Report No.:  EM201300534-2                Application No.:  ZJ00032799                        Page 21 of 58 
 
 
Project No.: 
ZJ00032799 
Polarziation: 
Horizontal 
Standard: 
(RE)EN55022 class B 
_3m_1-6GHz_PK 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-7-30 
Temp./Hum.(%RH): 20/54%RH 
Time: 
14:03:42 
EUT: 
Wireless speaker  system 
Distance: 
3m 
Model: JBL 
VOYAGER 
Test 
Result: 
Pass 
Note:  
Mode 3: BT (battery) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 93.3478 2.76  9.74  12.50  40.00 -27.50 
QP 
2 249.5707 9.14  13.66  22.80  47.00 -24.20 
QP 
 
Report No.:  EM201300534-2                Application No.:  ZJ00032799                        Page 22 of 58 
 
 
Project No.: 
ZJ00032799 
Polarziation: 
Vertical 
Standard: 
(RE)EN55022 class B 
_3m_1-6GHz_PK 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-8-11 
Temp./Hum.(%RH): 20/54%RH 
Time: 
14:49:22 
EUT: 
Wireless speaker  system 
Distance: 
3m 
Model: JBL 
VOYAGER  Test 
Result: 
Pass 
Note:  
Mode 3: BT (battery) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 1832.841 35.04  13.45  48.49  70.00 -21.51 
peak 
2 1832.841 18.05  13.45  31.50  50.00 -18.50 
AVG 
3 2015.009 37.13  14.14  51.27  70.00 -18.73 
peak 
4 2015.009 18.66  14.14  32.80  50.00 -17.20 
AVG 
5 2918.401 28.90  22.67  51.57  70.00 -18.43 
peak 
6 2918.401 15.63  22.67  38.30  50.00 -11.70 
AVG 
7 4809.826 28.45  27.74  56.19  74.00 -17.81 
peak 
8 4809.826 16.56  27.74  44.30  54.00  -9.70 
AVG 
 
Report No.:  EM201300534-2                Application No.:  ZJ00032799                        Page 23 of 58 
 
 
Project No.: 
ZJ00032799 
Polarziation: 
Horizontal 
Standard: 
(RE)EN55022 class B 
_3m_1-6GHz_PK 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-8-11 
Temp./Hum.(%RH): 20/54%RH 
Time: 
14:55:02 
EUT: 
Wireless speaker  system 
Distance: 
3m 
Model: JBL 
VOYAGER  Test 
Result: 
Pass 
Note:  
Mode 3: BT (battery) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 1832.841 32.19  13.45  45.64  70.00 -24.36 
peak 
2 1832.841 17.95  13.45  31.40  50.00 -18.60 
AVG 
3 2015.009 37.48  14.14  51.62  70.00 -18.38 
peak 
4 2015.009 19.06  14.14  33.20  50.00 -16.80 
AVG 
5 2910.033 28.65  22.57  51.22  70.00 -18.78 
peak 
6 2910.033 15.83  22.57  38.40  50.00 -11.60 
AVG 
7 4809.826 28.43  27.74  56.17  74.00 -17.83 
peak 
8 4809.826 16.96  27.74  44.70  54.00  -9.30 
AVG 
Report No.:  EM201300534-2                Application No.:  ZJ00032799                        Page 24 of 58 
 
 
4.2 CONDUCTED EMISSION MEASUREMENT 
4.2.1 LIMITS 
AC Power port 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
66~56 56~46 
0.5 ~ 5 
56 46 
5 ~ 30 
60 50 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
84~74 74~64 
0.5 ~ 30 
74 64 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
4.2.2 TEST PROCEDURES 
Procedure of Preliminary Test 
For measurement of the disturbance voltage the equipment under test (EUT) is connected to 
the power supply mains and any other extended network via one or more artificial network(s). 
An EUT, whether intended to be grounded or not, and which is to be used on a table is 
configured as follows: 
–   Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a 
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It 
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as 
follows: 
1)  place the EUT on a table of non-conducting material which is at least 80 cm high. Place the 
EUT so that it is 40 cm from the wall of the shielded room, or 
2)  place the EUT on a table of non-conducting material which is 40 cm high so that the 
bottom of the EUT is 40 cm above the ground plane; 
–    All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground 
plane; 
–    The ANs are placed on the floor that one side of the AN housings is 40 cm from the 
vertical reference ground plane and other metallic parts; 
–    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded 
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle 
between the ground plane and the table. 
–    I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the 
cable may be terminated if required using correct terminating impedance. The total length 
shall not exceed 1 m. 
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT configuration and cable configuration of the above highest emission 
Page of 58