JBL SUB 550P Service Manual ▷ View online

 
SUB 550P / 230 
Amplifier/Subwoofer
 
 
SERVICE MANUAL
 
 
 
 
 
 
 
 
 
 
 
 
JBL Consumer Products 
8500 Balboa Blvd. 
 
            
Released 
2012          Rev0 
 
 
01/2012 
Discontinued XXXX 
 
 
 
 
-  CONTENTS  - 
 
 
BASIC SPECIFICATIONS…………………………….….……………..
DETAILED SPECIFICATIONS………………………………………….
PACKAGING…………………………..…………………….……………
CONTROLS/CONNECTIONS..…… …………… …………..……….. 
OPERATION ………….…………………………..……….….………….
TEST SETUP AND PROCEDURE………….……………………….…
EXPLODED VIEW………………………….………………………….
..10 
2
30V BLOCK DIAGRAM..……………….…………………………..….11 
DETAILED TROUBLESHOOTING..…………………..………… ……1
2
30V ELECTRICAL PARTS LIST ……….…….…….………………..14 
INTEGRATED CIRCUIT/TRANSISTOR PINOUTS….…….………...2
PCB DRAWINGS………………..…………….………………………...2
2
30V SCHEMATICS.……….………………………………….……..…33 
 
 
SUB 550P BASIC SPECIFICATIONS 
 
Low-frequency transducer:  
 
10" (250mm) PolyPlas cone, cast basket 
Enclosure type:  
 
 
 
Sealed (forward-firing) 
Amplifier power:  
 
 
 
300 watts (RMS); 500 watts (peak) 
Frequency response:  
 
 
27Hz – 150Hz  
Audio controls:  
 
 
 
Volume level, crossover frequency, phase 
Connections:  
 
 
 
RCA line-level and LFE inputs 
Power requirement:  
 
 
120V, 60Hz (US); 220V – 230V, 50Hz/60Hz (EU) 
Power consumption:  
 
 
<6W (120V) standby 
360W (3.8A @ 120V) maximum 
<0.55W (230V) standby 
395W (2.1A @ 230V) maximum 
Dimensions (W x H x D):    
 
17-1/2" x 14-29/32" x 14-31/32"  
(44
4mm x 379mm x 380mm) 
Weight:  
 
 
 
 
50 lb (23kg) 
 
 
Occasional refinements may be made to existing products without notice but will always meet or exceed original 
specifications unless otherwise stated 
SUB 550P / 230
2
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-253
230
Vrms
Normal operation, MOMS required
No
90-110
100
Vrms
Normal Operation
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Load Impedance (speaker)
4
Ohms
n/a
Nominal
AVG System impedance
10.8
Ohms
n/a
AP Computed BW from 20 to 500Hz Refer to AP Graph
Rated Output Power 
250
Watts
220
AVG Peak voltage 
45.8
Vpk
Reference 170mV driven into a single input
Average PK voltage,  3/20 Cycles 50 Hz, Driven 
6dB above its input sensitivity , rated impedance
THD @ Rated Power
0.5
%
1
22K filter+AUX-0025
THD @ 1 Watt
0.2
%
0.3
22K filter+AUX-0025
DC Offset
10
mV-DC
50
@ Speaker Outputs
Damping factor
>50
DF
20
Measured at amplifier board  90% of
full power
Measured at the speaker cable.  225 Watts @ 
THD < 0.1 % @ 50 Hz
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
L&R
5.6
mVrms
±1dB
To 1 Watt, Ap Zo=25
Single input driven
LFE input
5.6
mVrms
±1dB
To 1 Watt, Ap Zo=25
Single input driven, LFE switch ON
System Gain
51
dB
Reference
Single input driven Normal or LFE mode
Signal to Noise
SNR-A-Weighted
80
dBA
75
relative to 1W-Inputs terminated
A-Weighting filter
SNR-unweighted
70
dBr
65
relative to 1W-Inputs terminated
22K filter
Residual Noise Floor
<2.0 mVrms(max)
2.5
Volume @max, w/ A/P Swept 
Bandpass Measurement (Line 
freq.+ harmonics) (BW=20 KHz)
Line level inputs must be terminated using    
1KOHM
Input Impedance
Line Input (L, R,LFE)
5.5K
ohms
n/a
Nominal
Filters
LP filter Variable
50-150 Hz
± 10
4th Order variable
Refer to AP curves 
Subsonic filter (HPF) 2nd Orde
Fixed
F=32Hz,Q=0.925
Refer to AP curves 
Friend circuit
Fixed
F=59Hz,Q=3.5, Av=-1dB
Refer to AP curves 
LFE Low pass 
Fixed
200>LP-LFE<500
Refer to AP curves 
Limiter 
THD at Max. Output Power
13
%
functional 
Drive unit 6dB above the required 
level to obtain full power 
Approximately 208mV
Maximum THD as a result of limiting.
Features
--
Volume pot Taper (lin/log)
LOG
--
functional 
A Taper
Phase switch 
0-180
deg
functional 
LP Filter defeat switch
YES
functional 
Disables LP filter, LFE Mode
LED Indicator
YES
functional 
Bi-color LED loacated at the amplifier panel, Red
Standby, Green-On
Input Configuration
Line In  (L,R) or LFE
YES
--
functional 
Dual  RCA jack, For LFE use L or R
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional 
ATO Input test frequency
50
Hz
functional 
"
ATO Level LFE Input
2
mV
functional 
"
Maximum acceptable level.
ATO Turn-on time
5
ms
functional 
Amp connected and AC on, then 
input signal applied
Auto Mute/ Turn-OFF Time
5-15
minutes
5-15
T before muting, after signal is 
removed
Auto turn of time (T)   must be  5 > T < 15 
Minutes
Power on Delay time
3
sec.
4
AC Power Applied
Transients/Pops
ATO Transient
0.5
V-peak
0.5V
@ Speaker Output
Amplifier activated by signal presence at the 
Line input
Turn-on Transient
0.5
V-peak
0.8V
@ Speaker Output
AC Line cycled from OFF to ON
Turn-off Transient
0.5
V-peak
0.8V
@ Speaker Output
AC Line cycled from ON to OFF
Detailed Specifications
SUB 550P / 230
3
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Efficiency & Consumption 
120V
Efficiency
65
%
65
Test conducted at rated power 245WNominal Line voltage 
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 120VAC
5.5
Watts
6.5
@ nom. line voltage 120VAC-60Hz Nominal Line voltage LED=>RED
Idle input power
11
Watts
13
@ nom. line voltage 120VAC-60Hz
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation. LED GREEN no signal applied
Power Cons. @ rated power
358
Watts
384
@ nom. line voltage 120VAC-60Hz 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
3.8
ARMS
Reference @ nom. line voltage 120VAC-60Hz
Efficiency & Consumption 
230VAC
Efficiency
65
%
62.5
Test conducted at rated power 250WNominal Line voltage 
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 230VAC
0.5
Watts
0.55
230VAC, 50-60Hz
Nominal Line voltage LED=>RED
Idle input power
15
Watts
16
@ nom. line voltage and Frequency
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation. LED GREEN no signal applied
Power Cons. @ rated power
393
Watts
400
@ nom. line voltage and Frequency 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
2.14
ARMS
Reference @ nom. line voltage and Frequency
Protections
Short Circuit Protection 
YES
functional  Direct short at output
Amplifier should resume operation after short 
circuit condition removal 
Thermal Protection 
YES
functional
@1/8 max unclipped Power at 1.06 
times the input voltage
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker 
output  under any operating condition including 
abnormal operation
Line Fuse Rating
USA-Domestic 3.15
Amps
3.15
EU
2.5
Amps
2.5
5x20mm Type-T-250 V, Low 
Breaking capacity
Transformer
Flux Density
<12.5
KGauss
n/a
@ Nom. line voltage
No Audible hum/buzz or excess idle current
Power losses
4.65
Watts
Reference
120VAC-60Hz
Magnetizing current
0.044
Amps
Reference RMS
120VAC-60Hz
All Agency Approvals
YES
n/a
Required per UL/CSA/SEMKO 
Standards
Refer to "Requirements" sheet
Other Parameters/Notes:
1. Limiter circuit response must be clean sounding with no apparent pops, noises, or pumping.
2. Plate dimensions not to exceed 11.81"H x 7.87"W and the plate must be airtight with no possibility of air leaks (plastic cover required).
3. Volume control should be at the input buffer stage  in order to lessen the possibility of clipping the input section with highly dynamic audio material.
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE. 
Rev-00 July-12-2011, Eng-reference sample
SUB 550P / 230
4
Page of 43
Display

JBL SUB 550P Service Manual ▷ Download

  • DOWNLOAD JBL SUB 550P Service Manual ↓ Size: 6.36 MB | Pages: 43 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the JBL SUB 550P in PDF for free, which will help you to disassemble, recover, fix and repair JBL SUB 550P Audio. Information contained in JBL SUB 550P Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.